谷歌浏览器插件
订阅小程序
在清言上使用

A Machine Learning Approach for Correcting Glow Curve Anomalies in CaSO4:Dy-based TLD Dosimeters Used in Personnel Monitoring.

Munir S. Pathan, S. M. Pradhan, T. Palani Selvam, B. K. Sapra

Journal of radiological protection(2023)

引用 0|浏览6
暂无评分
摘要
The study presents a novel approach to analysing the thermoluminescence (TL) glow curves (GCs) of CaSO4:Dy-based personnel monitoring dosimeters using machine learning (ML). This study demonstrates the qualitative and quantitative impact of different types of anomalies on the TL signal and trains ML algorithms to estimate correction factors (CFs) to account for these anomalies. The results show a good degree of agreement between the predicted and actual CFs, with a coefficient of determination greater than 0.95, a root mean square error less than 0.025, and a mean absolute error less than 0.015. The use of ML algorithms leads to a significant two-fold reduction in the coefficient of variation of TL counts from anomalous GCs. This study proposes a promising approach to address anomalies caused by dosimeter, reader, and handling-related factors. Furthermore, it accounts for non-radiation-induced TL at low dose levels towards improving the dosimetric accuracy in personnel monitoring.
更多
查看译文
关键词
personnel dosimeter,thermoluminescence,glow curve analysis,machine learning