Response of a 50 kW Organic Rankine Cycle System Subject to Influence of Evaporators

Energy Procedia(2014)

引用 0|浏览0
暂无评分
摘要
The variations of the evaporator on the system responses of a 50 kWe ORC system using R-245fa are investigated. The effect of exit superheat on the ORC system depends of the types of the evaporator. For the plate evaporator, an exit superheat less than 10°C may cause ORC system unstable due to liquid entrainment. For maintaining stable operation, the corresponding Jakob number of the plate heat evaporator must be above 0.07. On the other hand, no unstable oscillation of the ORC system is observed for an exit superheat of 0∼17°C when the shell-and-tube heat exchanger is used as the evaporator.
更多
查看译文
关键词
Dynamic response,Organic Rakine cycle,Evaporator,Plate heat exchanger,Shell-and-tube heat exchanger
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要