Determination of nine organic amine compounds in CO2 absorption liquid by hydrophilic interaction liquid chromatography-electrostatic field orbitrap high resolution mass spectrometry

Se pu = Chinese journal of chromatography(2023)

引用 0|浏览3
暂无评分
摘要
Carbon dioxide (CO2) absorption and capture is an effective measure to achieve the "dual carbon" goal of carbon peak and carbon neutrality in China. Organic amine compounds are widely used in the industrial separation and recovery of CO2. Thus, the establishment of analytical methods for organic amine compounds is of great significance for the research and development of carbon capture and storage (CCS) technology and carbon capture, utilization and storage (CCUS) technology. In this study, a method was developed for the determination of nine organic amine compounds in CO2 absorption liquid by hydrophilic interaction liquid chromatography (HILIC)-electrostatic field orbitrap high resolution mass spectrometry. The sample was diluted with water and filtered through a 0.22 mu m nylon membrane before sampling and analysis. An Accucore HILIC column (100 mmx2.1 mm, 2.6 mu m) was used for separation at 30 degrees C. Gradient elution was conducted using 90% acetonitrile aqueous solution containing 5 mmol/L ammonium formate and 0.1% formic acid as mobile phase A and 10% acetonitrile aqueous solution containing 5 mmol/L ammonium formate and 0.1% formic acid as mobile phase B. Determination was performed using an electrospray ion source (ESI) in the positive ion mode. The quantitative analysis was carried out by standard addition method. The chromatographic retention performance of different chromatographic columns and the influence of different mobile phases on the separation of the organic amine compounds were compared, and the method was validated. The results showed that the linear ranges of the nine organic amine compounds were 0.04-25000 ng/mL with the linear correlation coefficients (R-2) greater than 0.9910. The limits of detection (LODs) of the method were in the range of 0.0004-0.0080 ng/mL, and the limits of quantification (LOQs) of the method were in the range of 0.0035-0.0400 ng/mL. The average recoveries of the method ranged from 85.30% to 104.26% with relative standard deviations (RSDs) of 0.04%-7.95% at the spiked levels of 1, 1.5 and 3 times sample concentration. The established method was applied to detect the absorption waste liquid of a cement plant, and nine organic amine compounds could be effectively detected. The stability of the actual sample was tested, and the RSDs were 0.10%-6.35% in 48 h at 4 degrees C. The method is sensitive, rapid and accurate for the determination of the nine organic amine compounds in industrial waste water. It can provide reference for the detection of organic amine compounds, and provide strong technical support for the research and industrial application of CO2 capture technology.
更多
查看译文
关键词
hydrophilic interaction liquid chromatography (HILIC),electrostatic field orbitrap high resolution mass spectrometry,organic amine compounds,carbon dioxide (CO2) absorbent
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要