Predicted Cardiac Toxicity in Daily Cone-Beam CT-Based Online Adaptive Stereotactic Partial Breast Irradiation with Decreased PTV Margins

D. Keilty, J. Visak,S. Wang,L. Chen,D. N. Kim,M. Arbab,P. G. Alluri, X. Zhong, Z. Iqbal, T. Zhuang,B. Cai,H. Kim,R. D. Timmerman, M. H. Lin,D. D. M. Parsons, A. S. Rahimi

International journal of radiation oncology, biology, physics(2023)

引用 0|浏览0
暂无评分
摘要
Given the established relationship between low MHD and cardiac events, the significant decrease in MHD revealed in comparisons of 3-mm and 1-cm PTV A-SPBI plans of our first 8 patients is promising; we expect the forthcoming larger sample size to show significant differences in substructure doses. NTCP models created for non-IMRT breast plans and targets with higher heart exposure did not predict clinically-relevant differences in cardiac risk. NTCP model development for the low heart dose achieved with A-SPBI would define expected benefit in these patients; in their absence, daily adaptation should be considered in patients with unfavorable anatomy or cardiac risk factors.