In-situ Deposition Rate Measurement System to Improve the Accuracy of the Film Formation Process

APPLIED CHEMISTRY FOR ENGINEERING(2023)

引用 0|浏览6
暂无评分
摘要
The quartz crystal microbalance (QCM), commonly used in high vacuum deposition, becomes difficult to use when a thick film is deposited on the quartz, affecting the crystal's inherent vibration. In this study, a non-destructive optical measurement method was developed to measure the film's deposition rate during the in-situ film deposition process. By measuring the scattered laser intensity caused by the dimer in the parylene gas passing through the gas flow path, it was successfully confirmed that the ratio of the dimer in the parylene gas increases as the pyrolysis temperature decreases. Additionally, it was noted that the film's thickness and haze increase as the pyrolysis temperature decreases by confirming the characteristics of the visible parylene films. Through the research results, we aim to utilize the stable in-situ film deposition rate measurement system to control the precise film deposition rate of parylene films.
更多
查看译文
关键词
Optical measurement, Parylene-C, Thickness monitor system, Visible parylene film, CVD