谷歌浏览器插件
订阅小程序
在清言上使用

Influence of Magnetic Pole Ovality on the Unbalanced Magnetic Pull of a 1000 MW Hydro-generator Unit Installed with High Precision

Zhenwei Ji,Jiwen Zhang, Zhiwei Hu,Xingxing Huang, Tianyu Zhao,Zhengwei Wang

2022 International Conference on Environmental Science and Green Energy (ICESGE)(2022)

引用 0|浏览3
暂无评分
摘要
Rotor deformation is one of the key problems of large turbine generators. Previous studies mainly calculated the unbalanced magnetic pull (UMP) of turbine generators. Giant hydroelectric generators are huge in size and extremely complex in structure, so there are few relevant UMP analyses about them up to now. This paper uses a two-dimensional transient finite element method to calculate the transient magnetic field and reveal the effect of rotor deformation on the UMP of a 1000 MW hydro-generator in the time and frequency domains. Theoretical calculations are in good agreement with field measurements. The results of this investigation can provide scientifically valuable guidance for the manufacture and installation of structurally complex giant hydraulic turbine units.
更多
查看译文
关键词
1000 MW hydro-generator,unbalanced magnetic pull,rotor deformation,electromagnetic fields,transient finite element calculation
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要