Effects of the Rotor Mechanical Offset Angle on the Electromagnetic Performance of Dual Stator Wound-Field Flux Switching Machines

2023 IEEE International Magnetic Conference - Short Papers (INTERMAG Short Papers)(2023)

引用 0|浏览0
暂无评分
摘要
This study is concerned with the effect of the rotor mechanical offset (MO) angle on the electromagnetic performance of dual stator wound-field flux switching machines (DSWFFSMs). The focus is to find the optimum initial rotor position so that control of the machine can be facilitated. Using finite element analysis (FEA) and based on a cocktail of simulations, key electromagnetic performance indices such as average torque, torque ripple, power factor and efficiency are studied under dynamic on-load state, with the optimum MO angle established at 8°. The experimental test prototype has been developed and the test results are promised future extended paper version.
更多
查看译文
关键词
Dual stator,electromagnetic performance,finite element analysis,mechanical offset,wound-field flux switching machine
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要