Automated analysis and detection of epileptic seizures in video recordings using artificial intelligence

Pragya Rai, Andrew Knight, Matias Hiillos, Csaba Kertesz, Elizabeth Morales,Daniella Terney, Sidsel Armand Larsen, Tim Osterkjerhuus,Jukka Peltola,Sandor Beniczky

FRONTIERS IN NEUROINFORMATICS(2024)

引用 0|浏览2
暂无评分
摘要
Introduction: Automated seizure detection promises to aid in the prevention of SUDEP and improve the quality of care by assisting in epilepsy diagnosis and treatment adjustment. Methods: In this phase 2 exploratory study, the performance of a contactless, marker-free, video-based motor seizure detection system is assessed, considering video recordings of patients (age 0-80 years), in terms of sensitivity, specificity, and Receiver Operating Characteristic (ROC) curves, with respect to video-electroencephalographic monitoring (VEM) as the medical gold standard. Detection performances of five categories of motor epileptic seizures (tonic-clonic, hyperkinetic, tonic, unclassified motor, automatisms) and psychogenic non-epileptic seizures (PNES) with a motor behavioral component lasting for >10 s were assessed independently at different detection thresholds (rather than as a categorical classification problem). A total of 230 patients were recruited in the study, of which 334 in-scope (>10 s) motor seizures (out of 1,114 total seizures) were identified by VEM reported from 81 patients. We analyzed both daytime and nocturnal recordings. The control threshold was evaluated at a range of values to compare the sensitivity (n = 81 subjects with seizures) and false detection rate (FDR) (n = all 230 subjects). Results: At optimal thresholds, the performance of seizure groups in terms of sensitivity (CI) and FDR/h (CI): tonic-clonic- 95.2% (82.4, 100%); 0.09 (0.077, 0.103), hyperkinetic- 92.9% (68.5, 98.7%); 0.64 (0.59, 0.69), tonic- 78.3% (64.4, 87.7%); 5.87 (5.51, 6.23), automatism- 86.7% (73.5, 97.7%); 3.34 (3.12, 3.58), unclassified motor seizures- 78% (65.4, 90.4%); 4.81 (4.50, 5.14), and PNES- 97.7% (97.7, 100%); 1.73 (1.61, 1.86). A generic threshold recommended for all motor seizures under study asserted 88% sensitivity and 6.48 FDR/h. Discussion: These results indicate an achievable performance for major motor seizure detection that is clinically applicable for use as a seizure screening solution in diagnostic workflows.
更多
查看译文
关键词
seizure detection,epilepsy,motor seizures,biomarkers,signal processing,artificial intelligence
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要