Association of elastic power in mechanical ventilation with the severity of acute respiratory distress syndrome: a retrospective study

European Journal of Medical Research(2024)

引用 0|浏览4
暂无评分
摘要
Background Mechanical power (MP) is the total energy released into the entire respiratory system per minute which mainly comprises three components: elastic static power, Elastic dynamic power and resistive power. However, the energy to overcome resistance to the gas flow is not the key factor in causing lung injury, but the elastic power (EP) which generates the baseline stretch of the lung fibers and overcomes respiratory system elastance may be closely related to the ARDS severity. Thus, this study aimed to investigate whether EP is superior to other ventilator variables for predicting the severity of lung injury in ARDS patients. Methods We retrieved patient data from the Medical Information Mart for Intensive Care III (MIMIC-III) database. The retrieved data involved adults (≥ 18 years) diagnosed with ARDS and subjected to invasive mechanical ventilation for ≥ 48 h. We employed univariate and multivariate logistic regression analyses to investigate the correlation between EP and development of moderate-severe ARDS. Furthermore, we utilized restricted cubic spline models to assess whether there is a linear association between EP and incidence of moderate-severe ARDS. In addition, we employed a stratified linear regression model and likelihood ratio test in subgroups to identify potential modifications and interactions. Results Moderate-severe ARDS occurred in 73.4% (296/403) of the patients analyzed. EP and MP were significantly associated with moderate-severe ARDS (odds ratio [OR] 1.21, 95% confidence interval [CI] 1.15–1.28, p < 0.001; and OR 1.15, 95%CI 1.11–1.20, p < 0.001; respectively), but EP showed a higher area-under-curve (95%CI 0.72–0.82, p < 0.001) than plateau pressure, driving pressure, and static lung compliance in predicting ARDS severity. The optimal cutoff value for EP was 14.6 J/min with a sensitivity of 75% and specificity of 66%. Quartile analysis revealed that the relationship between EP and ARDS severity remained robust and reliable in subgroup analysis. Conclusion EP is a good ventilator variable associated with ARDS severity and can be used for grading ARDS severity. Close monitoring of EP is advised in patients undergoing mechanical ventilation. Additional experimental trials are needed to investigate whether adjusting ventilator variables according to EP can yield significant improvements in clinical outcomes.
更多
查看译文
关键词
Acute respiratory distress syndrome,Mechanical ventilation,Elastic power,Mechanical power,Severity assessment
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要