The Role of Proton Therapy for Prostate Cancer in the Setting of Hip Prosthesis

CANCERS(2024)

引用 0|浏览5
暂无评分
摘要
Simple Summary As proton therapy evolves and becomes more accessible, it is important to explore its potential value for all patient cases to enable more informed treatment individualization. Currently, external beam radiotherapy for prostate cancer patients with hip prosthesis is limited to photons because traditional proton therapy beams interfere with the implanted hardware. The goal of this study was to investigate the dosimetric feasibility and robustness of novel proton therapy techniques, i.e., proton arc therapy and anterior beam directions for prostate cancer patients with unilateral hip prosthesis. It was demonstrated that proton therapy for prostate cancer in the setting of hip prosthesis is feasible and could potentially reduce the dose to some critical organs and hence reduce toxicities.Abstract Purpose: Given that the current standard of proton therapy (PT) for prostate cancer is through bilateral beams, this modality is typically avoided when it comes to treatment of patients with hip prosthesis. The purpose of this study was to evaluate whether novel PT methods, i.e., anterior proton beams and proton arc therapy (PArc), could be feasible options to treat this patient subpopulation. We evaluate PT methods in the context of dosimetry and robustness and compare with standard of practice volumetric modulated arc therapy (VMAT) to explore any potential benefits. Methods: Two PT and one VMAT treatment plans were retrospectively created for 10 patients who participated in a clinical trial with a weekly repeat CT (rCT) imaging component. All plans were robustly optimized and featured: (1) combination anterior oblique and lateral proton beams (AoL), (2) PArc, and (3) VMAT. All patients had hydrogel spacers in place, which enabled safe application of anterior proton beams. The planned dose was 70 Gy (RBE) to the entire prostate gland and 50 Gy (RBE) to the proximal seminal vesicles in 28 fractions. Along with plan dose-volume metrics, robustness to setup and interfractional variations were evaluated using the weekly rCT images. The linear energy transfer (LET)-weighted dose was evaluated for PArc plans to ensure urethra sparing given the typical high-LET region at the end of range. Results: Both PT methods were dosimetrically feasible and provided reduction of some key OAR metrics compared to VMAT except for penile bulb, while providing equally good target coverage. Significant differences in median rectum V35 (22-25%), penile bulb Dmean (5 Gy), rectum V61 (2%), right femoral head Dmean (5 Gy), and bladder V39 (4%) were found between PT and VMAT. All plans were equally robust to variations. LET-weighted dose in urethra was equivalent to the physical dose for PArc plans and hence no added urethral toxicity was expected. Conclusions: PT for treatment of prostate cancer patients with hip prosthesis is feasible and equivalent or potentially superior to VMAT in quality in some cases. The choice of radiotherapy regimen can be personalized based on patient characteristics to achieve the best treatment outcome.
更多
查看译文
关键词
prostate cancer,hip prosthesis,proton arc therapy
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要