Chrome Extension
WeChat Mini Program
Use on ChatGLM

Our Estimates of Neonatal Radiation Exposure Fall Short of Reality.

Michelle Toscan,Breno Fauth de Araujo, Julio Cesar Martini, Rafaela Ravazio,Vandrea Carla de Souza

European journal of pediatrics(2024)

Cited 0|Views5
No score
Abstract
The purpose of this study is to evaluate radiation exposure in newborns undergoing imaging tests during the first 30 days of neonatal intensive care unit (NICU) hospitalization. A retrospective cohort study was conducted from November 2018 to April 2019 with newborns admitted to the NICU. Thermoluminescent dosimeters (TLD-100 (TM)) measured radiation emitted during imaging exams over 1 month, with a comparison between measured and estimated radiation. The cohort exhibited a median gestational age of 33.0 (31.0, 37.0) weeks, a median birth weight of 1840 (1272, 2748) g, and a median length of stay of 25.5 (11.7, 55.0) days. Eighty-four patients underwent 314 imaging tests, with an estimated radiation dose (ERD) per patient of 0.116 mSv and a measured radiation dose (MDR) of 0.158 mSv. ERD consistently underestimated MDR, with a mean difference of -0.043 mSv (-0.049 to -0.036) in the Bland-Altman analysis. The regression equation was as follows: difference MRD - ERD = -1.7 x (mean (MRD + ERD)) + 0.056. The mean estimated radiation dose per exam was 0.030 mSv, and the chest X-rays accounted for 63.26% of total exams. The median number of radiographic incidences per patient was 2 (1, 4), with 5 patients undergoing three or more exams in a single day.Conclusion: Radiation exposure in these newborns was underestimated, emphasizing the need for awareness regarding associated risks and strict criteria for requesting radiological exams. Lung ultrasound is a radiation-free and effective option in managing respiratory diseases in newborns, reducing the reliance on chest X-rays. What is Known:center dot Radiation used in diagnostic exams is not risk-free.center dot Radiation risk is much higher in small Infants due to the exposure area and the prolonged expectance of life.What is New:center dot Radiation exposure is underestimated in the neonatal population.center dot The study found a mean radiation exposure in neonates about 5% of the mean annual dose in the general population.
More
Translated text
Key words
Neonatology,Diagnostic imaging,Radiation exposure,X-rays
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Chat Paper
Summary is being generated by the instructions you defined