Reconstruction of Dose Rate Field and Algorithm Validation Based on Inverse Distance Weight Interpolation

NUCLEAR TECHNOLOGY(2024)

引用 0|浏览2
暂无评分
摘要
The inverse distance weighting (IDW) interpolation algorithm is used to reconstruct the gamma radiation field. The traditional IDW interpolation algorithm is improved. The power exponent of distance P in the IDW for each interpolation point is not fixed and varies from one point to the other point. A fitting expression of P is obtained, which is a function of the coordinates of each point and can minimize the interpolation error when the number of sampling points is specified. Afterward, the improved algorithm is used to reconstruct a gamma radiation field of a single source, and the theoretic results are compared with the results from Geant4, yielding an average relative error of 7.50%. The interpolated results from the experimental measurements align well with the actual data, with an average relative error of only 0.12%. The P derived from the interpolated experimental measurement data shows an error of 2.0% compared to the power exponent obtained from the Geant4 data interpolation. Then we set up a double-source gamma radiation scene experiment and measured the count rate data at the grid points. At the same time, the experiment scene was simulated by Geant4. The improved IDW algorithm could not reconstruct the double-source gamma radiation field well, thus further improvement is needed.
更多
查看译文
关键词
Radiation field reconstruction,single source,improved inverse distance weighting,IDW, Geant4
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要