Intraocular pressure changes before and after a femtosecond laser procedure for cataract surgery.

Scientific reports(2024)

引用 0|浏览3
暂无评分
摘要
This study aimed to evaluate the changes in intraocular pressure (IOP) before and after femtosecond laser capsulorhexis and lens fragmentation for cataract surgery. We measured the IOP before, immediately, 30 min, and 1 h after the laser procedure in 47 eyes of 47 patients who underwent the femtosecond laser procedure. The mean IOP was 17.51 ± 3.28 mmHg, 30.23 ± 6.70 mmHg, 17.96 ± 3.75 mmHg, and 21.77 ± 5.88 mmHg before, immediately after, 30 min after, and 1 h after the laser procedure, respectively. The mean IOP significantly increased immediately (adjusted P < 0.001) and 1 h (adjusted P = 0.001) after the laser procedure compared with the pre-laser IOP. The mean IOP at 30 min after the laser procedure was significantly lower than that immediately after the procedure (adjusted P < 0.001). However, the IOP 1 h after the laser procedure became higher than that 30 min after the laser procedure. Additionally, the IOP 1 h after the laser procedure was positively correlated with the baseline IOP and negatively correlated with the axial length. In conclusion, this study demonstrated that cataract surgery should be commenced within 30 min after the femtosecond laser procedure to ensure a safe cataract surgery that reduces the risk of increased intraocular pressure.