谷歌浏览器插件
订阅小程序
在清言上使用

Mechanical Design of ITER Radial Neutron Camera Ex-Port System

Fusion engineering and design(2024)

引用 0|浏览7
暂无评分
摘要
The Radial Neutron Camera is an ITER diagnostic designed to measure the un-collided 14 MeV and 2.5 MeV neutrons from deuterium-tritium (DT) and deuterium-deuterium (DD) fusion reactions, through an array of detectors covering a poloidal plasma section along collimated Lines Of Sight (LOS). It is composed by two fan-shaped collimating structures viewing the plasma radially through vertical slots in the diagnostic shielding module of ITER Equatorial Port 1: the In-Port RNC, devoted to plasma edge coverage, and the Ex-Port RNC, devoted to the plasma core coverage. This paper presents an overview of the mechanical design of the Ex-Port RNC at the Preliminary Design Review (PDR) stage. The Ex-Port RNC is located in the Port Interspace and consists of a massive shielding structure hosting the detector units and two sets of collimators lying on different toroidal planes. The Ex-Port RNC design is presented both from the point of view of functional requirements (e.g. LOS positions and angles, radiation shielding, weight limitations) and of manufacturability. Finally, the Ex-port RNC structural integrity is assessed, and its design validated against the main loads and load combinations.
更多
查看译文
关键词
ITER,Radial neutron camera,Ex -Port,Design description,Structural integrity,Finite element method