谷歌浏览器插件
订阅小程序
在清言上使用

Simultaneous determination of eight organic amines in desulfurization solution by ion chromatography

Gao Lihong, Jiang Zhenbang,Zheng Hongguo,Li Wenhui

CHINESE JOURNAL OF CHROMATOGRAPHY(2024)

引用 0|浏览5
暂无评分
摘要
The applications of organic -amine desulfurization have steadily increased owing to its high efficiency, low cost, and low energy consumption. Different proportions of organic amines exert different effects on sulfur dioxide removal. Therefore, the accurate determination of different organic amines in the desulfurization solution is of great importance. The ion-chromatographic method for the detection of organic amines does not require a derivatization step, has simple pretreatment procedures, and allows for the simultaneous determination of many types of organic amines. In this study, a method based on ion chromatography was developed for the simultaneous determination of ethanolamine ( MEA), diethylethanolamine ( DEEA), n-methyldiethanolamine ( MDEA), 2- amino -2 -methyl- 1-propanol ( AMP), hydroxyethylethylenediamine ( AEEA), piperazine ( PZ), n-hydroxyethylpiperazine ( HEPZ), and diethylenetriamine ( DETA). The separation efficiency of the eight organic amines in different types of columns, leaching solutions, and column temperatures were compared. The determination was performed using an IonPac CS17 column with column temperature of 35 degrees C and gradient leaching with methyl sulfonic acid ( MSA) solution via the inhibition conductance method. Samples of the desulfurization solution were analyzed using ultrapure water filtered through a 0. 22 mu m nylon microporous filter membrane and an OnGuard II RP column; thus, the pretreatment steps are simple. The eight organic amines showed a good linear relationship within a certain concentration range, and the coefficient of determinations (R-2) were greater than 0. 998. The limits of detection ( LODs) and quantification ( LOQs) were determined from the mass concentrations of the organic amines corresponding to signal-to-noise ratios (S/N) of 3 and 10, respectively. LODs of 0. 02-0. 08 mg/L and LOQs of 0. 07-0. 27 mg/L were determined from a 1.0 mu L sample injection. The actual recoveries ranged from 93. 0% to 111%, and the relative standard deviations ( RSDs, n = 5) ranged from 0. 31% to 1. 2%. The results indicated that the proposed method has good accuracy and precision; thus, it is suitable for the determination of various organic amines in desulfurization solution.
更多
查看译文
关键词
ion chromatography ( IC),organic amines,desulfurization solution
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要