The French Society of Rheumatology recommendations for managing rheumatoid arthritis (RA) has been updated by a working group of 21 rheumatology experts, 4 young rheumatologists and 2 patient association representatives on the basis of the 2023 version of the European Alliance of Associations for Rheumatology (EULAR) recommendations and systematic literature reviews. Two additional topics were addressed: people at risk of RA development and RA-related interstitial lung disease (RA-ILD). Four general principles and 19 recommendations were issued. The general principles emphasize the importance of a shared decision between the rheumatologist and patient and the need for comprehensive management, both drug and non-drug, for people with RA or at risk of RA development. In terms of diagnosis, the recommendations stress the importance of clinical arthritis and in its absence, the risk factors for progression to RA. In terms of treatment, the recommendations incorporate recent data on the cardiovascular and neoplastic risk profile of Janus kinase inhibitors. With regard to RA-ILD, the recommendations highlight the importance of clinical screening and the need for high-resolution CT scan in the presence of pulmonary symptoms. RA-ILD management requires collaboration between rheumatologists and pulmonologists. The treatment strategy is based on controlling disease activity with methotrexate or targeted therapies (mainly abatacept or rituximab). The prescription for anti-fibrotic treatment should be discussed with a pulmonologist with expertise in RA-ILD.
Background Marginal bone loss has been reported as an important factor that affects the ultimate long-term outcome of a dental implant. It has been hypothesized that the design of the implant crest module (i.e. presence of retention elements, as threads) may influence the extent of periimplant marginal bone loss. However, the specific impact of implementing threads in the implant neck region on marginal bone level preservation needs to be better understood. Aim/Hypothesis To evaluate clinical, bacteriological, and biomechanical aspects of threaded (Th) and non-threaded (nTh) implant crestal module designs on marginal periimplant bone loss. Material and Methods Twelve patients received two custom made Ø 3.8 x 13 mm implants, Morse-taper Th or nTh implants, randomly placed based on a split-mouth design. Clinical parameters were evaluated at 6 sites around the implants, at a 12 month follow-up. The distance from the top of the implant to the first bone-to-implant contact – IT-FBIC was evaluated on standardized digital peri-apical radiographs acquired at 1, 3, 6, 12, 36, and 60 months follow-up. Samples of the subgingival microbiota were collected 1, 3 and 6 months after implant loading. DNA were extracted and used for the quantification of Tf, Aa, Pi and Fn. Comparison among multiple periods of observation were performed using repeated-measures Analysis of Variance (ANOVA), followed by a Tukey post-hoc test, while two-period based comparisons were made using paired t-test. Further, 36 computer-tomographic based finite element (FE) models were accomplished and relevant biomechanical aspects were interpreted by means of ANOVA. Results The variation in periimplant bone loss assessed on the periapical radiographs was significantly different between threaded and non-threaded implants (P = 0.022). Mean IT-FBIC was 0.48 ± 0.70 mm for Th and 0.99 ± 0.29 mm for nTh, after 5 years of implant loading. All assessed clinical parameters were statistically equal. No significant microbiological differences could be observed between Th and nTh implants. Most of the plaque samples had very few pathogens meaning that these regions were healthy from a microbiological point of view. In FE analysis, peaks of EQV strain were comparable between both the implant crestal module designs (mean Th 841.0 με, nTh 767.1 με). However, the nTh (mean 1.54 ± 1.25 mm3) implant presented a significantly higher (P = 0.006) bone volume affected by a shear stress above 5 MPa, comparing with Th (mean 0.2 ± 0.14 mm3). Conclusion and Clinical Implications Based on the present findings, implementing threads in the implant crestal module is beneficial for long-term periimplant bone preservation. No significant effects of such threads were seen based on the clinical or microbiological evaluated parameters. A threaded collar significantly reduced the amount of bone affected by shear stresses.
Background Bone-retention elements such as threads and rough implant surfaces have been advocated as means to reduce the amount of periimplant bone loss by increasing the contact area between the bone and implant interface, therefore reducing stress strain magnitudes at the cortical alveolar crest. However, the exact impact of either the presence of threads or the roughened surface at implant crestal module on the maintenance of marginal bone levels still needs to be better clarified. Aim/Hypothesis To evaluate the clinical, bacteriological, and biomechanical aspects of surface treatment in the threaded implant crestal module design with (MT) or without (MTwT) surface treatment, on peri-implant bone loss. Material and Methods Twelve patients received two custom made Ø 3.8 x 13 mm Morse-taper MT or MTwT implants, randomly placed based on a split-mouth design. Clinical parameters were evaluated at 6 sites around the implants, at a 12 month follow-up. The distance from the top of the implant to the first bone-to-implant contact – IT-FBIC was evaluated on standardized digital peri-apical radiographs acquired at 1, 3, 6, 12, 36, and 60 months follow-up. Samples of the subgingival microbiota were collected 1, 3 and 6 months after implant loading. DNA were extracted and used for the quantification of Tf, Aa, Pi and Fn. Comparison among multiple periods of observation were performed using repeated-measures Analysis of Variance (ANOVA), followed by a Tukey post-hoc test, while two-period based comparisons were made using paired t-test. Further, 36 computer-tomographic based finite element (FE) models were accomplished and the results for the peak EQV strain in periimplant bone were interpreted by means of ANOVA. Results Not-statistically significant differences in periimplant bone loss could be demonstrated by implementing surface treatment in threaded crestal modules (P = 0.1672). Mean IT-FBIC was 0.48 ± 0.70 mm for MT and 0.65 ± 0.57 mm for MTwT, after 5 years of implant function. Further, all assessed clinical parameters were statistically similar. In addition, no significant microbiological differences could be observed between MT and MTwT implants. Most of the evaluated sites had very few pathogens meaning that these regions were healthy from a microbiological point of view. FE analysis, however, showed a slightly higher peak of EQV strain (P < 0.001) for MTwT (mean 1,681.1 με) compared to MT (mean 840.98 με). Conclusion and Clinical Implications No additional benefit of surface treatment on periimplant bone maintenance could be found for Morse-taper implants with threaded crestal modules. However, no detrimental effects of surface treatment on clinical and bacteriological evaluations could be demonstrated. As lower strain values could be found in periimplant bone for surface treated collars in higher loading magnitudes, one can speculate this to be an advantage under more challenging clinical situations.
Background The biological width formation, the inflammatory reactions due to the implant-abutment microgap contamination, the periimplant stress strain concentration causing bone microdamage accumulation and or a foreign body response, characterized by a chronic inflammation in soft tissue, have been suggested to explain early periimplant bone loss. However, it is yet not well understood to which extent the implant-abutment connection type may influence the remodeling process around dental implants. Aim/Hypothesis to evaluate clinical, bacteriological and biomechanical parameters related to periimplant bone loss at the crestal region, comparing external hexagon (EH) and Morse-taper (MT) connections. Material and Methods Twelve patients received two custom made Ø 3.8 x 13 mm implants, EH or MT, randomly placed based on a split-mouth design. Clinical parameters were evaluated at 6 sites around the implants, at a 12 month follow-up. The distance from the top of the implant to the first bone-to-implant contact – IT-FBIC was evaluated on standardized digital peri-apical radiographs acquired at 1, 3, 6, 12, 36, and 60 months follow-up. Samples of the subgingival microbiota were collected 1, 3 and 6 months after implant loading. DNA were extracted and used for the quantification of Tf, Aa, Pi and Fn. Comparison among multiple periods of observation were performed using repeated-measures Analysis of Variance (ANOVA), followed by a Tukey post-hoc test, while two-period based comparisons were made using paired t-test. Further, 36 computer-tomographic based finite element (FE) models were accomplished and the results for the peak EQV strain in periimplant bone were interpreted by means of ANOVA. Results The variation in periimplant bone loss assessed by means of radiographs was significantly different between the connection types (P < 0.001). Mean IT-FBIC was 1.66 ± 0.83 mm for EH, and 0.48 ± 0.70 mm for MT, considering all evaluated time periods. All clinical parameters presented not significant differences. No significant microbiological differences could be observed between both connection types. Most of the collected samples had very few pathogens, meaning that these regions were healthy from a microbiological point of view. In FE analysis, a significantly higher peak of EQV strain (P = 0.005) was found for EH (mean 3,438.65 με) compared to MT (mean 840.98 με) connection. Conclusion and Clinical Implications Varying implant-abutment connection type will result in diverse periimplant bone remodeling. Clinical and microbiological conditions could not be demonstrated as responsible for marginal bone loss, after the first year of implant function. The present findings suggest that a Morse-taper connection is more efficient to prevent long-term periimplant bone loss, compared to an external hexagon connection.
Introducao: Tratamentos endodonticos insatisfatorios apresentam restos pulpares necroticos com proliferacao bacteriana causando processos inflamatorios periapicais reabsortivos. Objetivos: Este trabalho tem por objetivo apresentar a importância do correto preparo mecânico-quimico e limpeza foraminal para melhor prognostico de um retratamento endodontico. Relato de caso: Paciente do genero feminino, G.R.C.L., 37 anos, compareceu a clinica odontologica queixando dor a mastigacao no dente 46. Apos serem feitos os testes de sensibilidade pulpar, palpacao e avaliacao radiografica, foi possivel identificar que o elemento 46 apresentava tratamento endodontico insatisfatorio envolvido por imagem radiolucida correspondente a reabsorcao ossea periapical. Discussao: Apos apresentar dor na regiao inferior do lado direito ao mastigar, a paciente G.R.C.L. procurou atendimento odontologico. Apos exames para diagnosticar a causa, definiu-se uma Periodontite Apical Cronica no dente 46. A guta-percha foi removida com lima reciprocante e irrigacao abundante com hipoclorito de sodio 2,5%. A limpeza dos forames foi feita com limas manuais. Apos 30 dias com hidroxido de calcio intracanal, o dente apresentou-se assintomatico e o canal foi seco e devidamente obturado com guta-percha, oxido de zinco e eugenol. Conclusao: Controle semestral evidenciou o reparo osseo caracterizando o sucesso deste protocolo de retratamento endodontico.