The National Laboratory Accelerator Study Group (NLASG) was established to assess the accelerator research and development required to advance a future high-energy Muon Collider, with particular emphasis on opportunities for coordinated contributions from U.S. national laboratories. This report examines the principal accelerator subsystems, their technical maturity, and the critical challenges that must be addressed before proceeding to a technical design. Topics include the proton driver, target and capture system, muon cooling, acceleration, collider ring, and machine-detector interface. The study identifies priority R D activities, evaluates opportunities to leverage existing laboratory capabilities and accelerator infrastructure, and outlines a staged approach to technology demonstrations and integrated system validation. Particular emphasis is placed on developing a coordinated national research strategy that complements international efforts and establishes a technically credible path toward a future Muon Collider.
Abstract Thermoplastic polymers are increasingly adopted in automotive applications due to their compatibility with high-volume manufacturing, reduced weight, and improved processing efficiency. However, their mechanical response at intermediate strain rates (1–100 s−1), representative of crash conditions, remains insufficiently understood. In particular, large pre-yield deformations and post-yield instabilities limit the applicability of conventional test methods, resulting in a lack of reliable tensile data and constitutive models for accurate impact simulations. To address this gap, a symmetric, double-acting drop-weight impact apparatus was employed to characterize the intermediate strain-rate tensile behavior of five automotive-grade thermoplastics. Baseline rate sensitivity was established through quasi-static testing at four strain rates, followed by dynamic tests conducted at drop heights of 10, 20, and 25 in. Drop height was selected as the control parameter, as the achieved strain rate varied with polymer morphology. Digital image correlation confirmed a homogeneous strain field across the gauge length for all materials, demonstrating the reliability of the test configuration. The results indicate increasing tensile strength and decreasing failure strain with increasing strain rate, with material-specific trends governed by microstructural differences. Strain-rate sensitivity was quantified using strain-averaged power-law relationships calibrated directly from experimental data. Together, the experimental methodology and constitutive modeling provide a robust framework for incorporating intermediate strain-rate effects of thermoplastics into impact-critical design and simulation tools.
PyARC is a user-friendly fast reactor analysis tool that automates multiphysics workflows using the "extended suite" of Argonne Reactor Computation (ARC) codes by providing a single common input for model definition, code execution, and output post-processing. A lead fast reactor (LFR) benchmark model is used to perform depletion calculations using the newly integrated OpenMC depletion capability in PyARC, building on previous analysis using the ARC codes through PyARC and Serpent. Results for core lifetime k-effective, shutdown decay heat, and end-of-life heavy-metal inventory are compared to verify the PyARC/OpenMC integration against the PyARC/ARC workflow and Serpent for depletion analysis of LFR designs. The results show satisfactory agreement among all three methods, with remaining discrepancies largely attributable to differences in nuclear data libraries and decay-chain modeling detail rather than to fundamental modeling limitations.
Effective clinical and public health decision-making during a pandemic depends on reliable and interoperable clinical diagnostic test results. To ensure trustworthy outcomes, we need widely available calibration standards harmonized to a shared scale. We present a “playbook” for an interlaboratory harmonization study that calibrates any available standards against a limited-availability standard issued by a global authority like the World Health Organization (WHO).
The Jezebel plutonium critical assembly, operated from 1954 to 1977, has been a benchmark for validating nuclear data, particularly for fast 239Pu fission, over the past 70 years. However, since its disassembly decades ago, there have been issues with Jezebel's legacy, including incomplete documentation, limited opportunities for long-term system parameter observations, and a lack of means to test new advancements using the same assembly.Given these challenges, there is a pressing need for a new, enduring benchmark plutonium critical assembly capable of providing ongoing validation and data collection. Such an assembly would assist in nuclear data validation, reactor kinetics, dosimetry, and many other areas of nuclear research while helping maintain U.S. leadership in plutonium research.The concept of Lilith, a new enduring plutonium assembly currently under development, is introduced as a potential solution to address these needs. The design of Lilith focuses on a simple geometry, low uncertainties, and a planned lifetime of 100 years. Lilith will use a cylindrical design, which will allow for easier manufacturing and greater flexibility in adjusting its components over time.The enduring nature of the system will enable ongoing validation of nuclear data, analytical methods, dosimetry, reactor kinetics, and material properties across decades. This would also provide the opportunity for new measurements of reactor kinetics parameters using neutron noise methods, and long-term criticality studies, while tracking changes in the plutonium system over time. This work highlights the importance of such a system for future advancements in nuclear technology and the need to ensure the continued availability of such research capabilities.