朗盛集团是一家德国特殊化学品集团,总部及主要业务运营位于科隆。2004年,拜耳集团进行战略重整分拆,将其化学品业务和部分聚合物业务进行了剥离,朗盛随之诞生。 按销售额计算,朗盛是德国第四大化学品集团。公司的产品主要集中在特殊化学品、基础化学品、精细化学品、橡胶和塑料等领域。
This study presents a comprehensive assessment of 36 commercially available generic glutaraldehyde products used in oil and gas microbial control programs, benchmarked against a high-purity industrial reference. Multi-tiered evaluation including titrimetric, chromatographic, and thermal stability analyses revealed significant quality discrepancies. While 53% of the products passed titrimetric assay for total aldehyde content, only 18% met both active ingredient and purity requirements upon HPLC and GC-MS evaluation. Formaldehyde and glyoxal adulterants were detected in 31% and 11% of the samples, respectively, raising concerns over toxicity, efficacy, and regulatory compliance. Physicochemical analysis showed that only 25% of products met the optimal pH window (3.1–4.5), and 28% adhered to acceptable methanol limits (≤0.5%). Thermal aging further revealed active ingredient degradation up to 12.9%, accompanied by discoloration, monomer release, and post-dilution polymerization in over 89% of samples. Microbiological performance, assessed through log reduction assays before and after heat aging, confirmed that adulterated or unstable formulations lost up to 70% of their antimicrobial efficacy post-aging. In contrast, the control product remained chemically stable and biologically effective throughout. These results underscore the critical importance of sourcing glutaraldehyde from reliable and validated suppliers. Poor-quality formulations not only compromise microbial control but also pose serious risks to health, safety, equipment integrity, and reservoir sustainability, reinforcing the need for stringent procurement and quality assurance protocols in oilfield operations.
Oil and gas seawater injection facilities present complex microbiological environments where harmful microorganisms can proliferate, leading to issues such as biofouling, corrosion, and reservoir souring. This study presents a comprehensive microbiological audit of the largest seawater treatment facility in the Middle East for oil reservoir injection with a capacity of 14 million barrels per day (BPD}. The seawater is treated from the Arabian Gulf and transport across the giant Ghawar and Khurais fields for water injection facilities. During the study, an integrated approach was employed using ATP measurements, bug bottles, qPCR, and NGS to characterize the microbial communities throughout the system. The results demonstrate the value of combining multiple methodologies to obtain a detailed understanding of microbial diversity and activity. ATP provided rapid assessments of overall biomass, bug bottles enabled the isolation and identification of culturable species. qPCR targeted specific functional genes associated with detrimental microbial groups, such as sulfate-reducing bacteria and Archaea. NGS sequencing provided the most comprehensive view of microbial community composition, including unculturable organisms. Importantly, we observed significant shifts in the microflora before and after biocide addition. This integrated approach revealed changes in microbial populations along the seawater injection system and highlighted the biocide's efficacy in targeting specific organisms.
Die Konzeption des „Evergreen Automatisierungssystems“ zielt darauf ab, in der Prozessautomatisierung Innovation und effektives Lebenszyklusmanagement zu integrieren. Die Einführung und Beherrschung solcher Systeme sind mit einer Reihe von Herausforderungen verbunden, die dieser Beitrag detailliert aufzeigt. Die Vision besteht in der Schaffung nachhaltiger und widerstandsfähiger Automatisierungssysteme, die Effizienzsteigerungen ermöglichen und gleichzeitig den komplexen Anforderungen moderner Automatisierungsumgebungen entsprechen.
Summary To ensure a sustainable energy transition from fossil fuels, hydrogen (H2), a universal energy carrier, is playing a significant role during this process. To sustain H2 for industrial applications, large-scale storage systems are required to guarantee a secure and continuous supply of H2. Given H2's volatility and volumetric needs, underground storage emerges as the preferred mid- to long-term option. Underground hydrogen storage (UHS) within porous media, aquifers, and caverns have been proposed to be optimal options for intermittent H2 storage. However, the heterogeneity between the different geological formations, parameters, and conditions will yield distinct microbial communities, which will compromise the H2 storage life cycle. Studies have shown that microorganisms are highly active within potential UHS sites using H2 as an electron donor and mineral components such as sulfates, carbonates, as electron acceptors. As an emerging technology, there is little to no knowledge existing on microbial mitigation of UHS. Our project aims to bridge the pre-existing knowledge obtained from the oil and gas industry on biocide and natural inhibitor applications to UHS operations. By defining a versatile strategy for the different types of UHS, we aim to standardize a sustainable mitigation approach to ensure the success implementation of UHS.