Coordinates: 38°04′58″N 114°30′32″E / 38.0828°N 114.5089°E / 38.0828; 114.5089Shijiazhuang Tiedao University (abbreviated STDU, also known as Tieda and Tieyuan; Chinese: 石家庄铁道大学), is a national key university in China, specialised in transportation science, engineering and technology and information technology, etc. STDU is currently under the joint administration of the People's Government of Hebei Province, the Ministry of Education of the People's Republic of China, State Administration of Science, Technology and Industry for National Defence of the People's Republic of China and National Railway Administration of the People's Republic of China. It has been selected, with Tsinghua University, Zhejiang University, Shanghai Jiaotong University, Beijing Jiaotong University, Beijing Institute of Technology and other key universities, for the "Educating and Training Program for Outstanding Engineers" (教育部"卓越工程师教育培养计划") of the Ministry of Education. In 2016, STDU was listed as the key supporting first-class universities and first-class-discipline construction university.STDU was formerly known as the Railway Engineering Institute of the People's Liberation Army (Army), founded in 1950, and was then one of the key universities in the Army. In 1979, STDU was listed as a national key university. In 1984, it was transferred to and under the administration of the Ministry of Railways of the People's Republic of China and renamed as Shijiazhuang Railway Institute. In 2000, it was transferred to Hebei Province, implementing jointly construction by the central government and the local government. In March 2010, it was renamed as Shijiazhuang Tiedao University.As of July, 2018, STDU has nineteen schools and departments and twenty-five research institutes. There are fifty-one undergraduate majors. STDU currently has more than 1,400 staff, 23,800 full-time undergraduate students and 2,700 postgraduates at both masters and doctorals levels.Its campus is situated in the suburb of Shijiazhuang city, the provincial capital of Hebei Province..
To address the excessive pipe-soil frictional resistance in dry sandy soil during pipe jacking, this study developed axially grooved bionic pipe sections inspired by the grooved surface of pangolin scales. Taking the drag reduction rate as the optimization index, this study investigated the effects of groove width (w), depth (d) and number (n) on pipe-soil frictional resistance through orthogonal experiments. Moreover, to explore the potential drag reduction mechanisms, the relationship between the grooved area ratio and the average drag reduction rate was quantitatively analyzed, regression models were established, and semi-empirical revised equations for pipe-soil frictional resistance were proposed for axially grooved bionic pipe sections in dry sandy soil. Results showed that both bionic circular and rectangular pipe sections exhibited superior drag reduction performance compared to conventional ones. Under the dry sandy soil test conditions of this study, the order of influence of the structural parameters on pipe-soil frictional resistance was w > n > d. The optimal parameter combination for bionic circular and rectangular pipe sections (i.e., w = 20 mm, d = 2 mm, n = 12) achieved a drag reduction rate of approximately 28%. The average drag reduction rate increased with the grooved area ratio, and the semi-empirical revised equations agreed well with the experimental data. These results demonstrate the laboratory scale potential of the proposed bionic structure as a complementary drag reduction approach to conventional slurry lubrication and provide a basis for subsequent large-scale and field validation.
The energy consumption from vessel waiting and handling at ports needs to be addressed, giving rise to policies such as Shore Power Connection (SPC) and Just In Time (JIT). However, converting these policies into operational decision metrics is challenging. This study fills that gap by embedding key indicators, such as Berth Occupancy Rate (BOR), Shore Power Utilization Ratio (SPUR), Quay Crane Utilization Ratio (QCUR), and Average Vessel Completion Rate (AVCR), into a novel optimization model for the integrated Berth Allocation and Quay Crane Scheduling Problem (BAQCSP). The model incorporates a dynamic prediction mechanism to estimate quay crane handling times, accounting for real-world variables such as tidal conditions and container stowage positions. Experimental results demonstrate that the proposed model demonstrates superior performance in resource utilization compared to sequential scheduling, single-objective optimization, and fixed quay crane handling time strategies. Additional ablation studies quantify the individual impact of each sustainability indicator on scheduling outcomes. The findings provide port authorities with actionable evidence to operationalize sustainability goals into enforceable strategies.
Abstract Due to the low reactivity and poor volume stability of steel slag (SS), its application in construction materials is limited. In particular, the divalent metal oxide solid solution (RO phase), due to its poor grindability, presents significant challenges for the effective activation of SS. In this study, three types of microorganisms were selected to activate SS and RO phases with different compositions. The activation mechanisms were investigated through tests on activity index, particle size distribution, and microstructure. Results showed that, under the synergistic effects of bioacid dissolution and microbial decomposition, the particles of RO/SS became finer and their reactivity improved to varying extents. Acidithiobacillus ferrooxidans ( A. ferrooxidans ), capable of utilizing Fe 2 + as a nutrient source, exhibited the best activation effect on FeO-rich RO phases, increasing the activity index from 58% to 91%. Bacillus mucilaginosus ( B. mucilaginosus ), known for its high alkali resistance, was more effective for MgO-rich RO phases, enhancing the activity index from 74% to 98%. Further, the volume stability of SS was also improved after microbial treatment, with the expansion rate reduced by 61% in samples treated with Aspergillus niger ( A. niger ).
Bolted joints are critical load-transfer nodes in single-axis photovoltaic (SAPV) support structures, but manual corrosion inspection is inefficient, subjective, and poorly traceable. This study proposes an automated robotic vision framework for SAPV bolt corrosion inspection, quantification, and digital damage mapping. The main contributions are as follows: (1) a mobile robot acquires close-range bolt images along predefined paths; (2) SDA-YOLO detects and segments small bolts and corrosion regions under complex field conditions; (3) MACRA converts corrosion masks into area ratios, actual areas, and damage grades; and (4) component-level indexing maps local results to global damage nodes with spatial location, component affiliation, and corrosion attributes. Field experiments validate automated image acquisition, corrosion recognition, quantitative assessment, and damage map generation for SAPV support maintenance.
Abstract Experimental results of the modular frame-shear wall demonstrate that the unrestrained frame-shear wall structure is prone to out-of-plane buckling deformation at the steel plate edges, leading to tearing failure. For the concrete restraint frame-shear wall, the restraint components provide effective out-of-plane constraint, thereby enhancing the energy dissipation capacity. However, the constraint effect on the steel plate edges is still insufficient. Based on the test results, an enhanced modular frame-shear wall with stiffening frame is proposed. This structure demonstrates a more gradual stiffness degradation trend combined with favorable ductility and energy dissipation capacity. Through the buckling analysis of the substructure (corrugated steel plate and stiffening frame), it is revealed that the existence of an optimal design stiffness ratio exists between components. Furthermore, the recommended ranges of stiffening frame thickness, subplate width, and corrugation height are proposed. Moreover, the stiffness ratio between the corrugated steel plate and the stiffening frame should be, in accordance, within 0.95 ≤ ζ ≤ 5.5 . Finally, the calculation formula of substructure critical buckling stress and a design method for restraint concrete are established, which can be used for the design and application of such structures.