• 学术搜索
  • 科研智能体
    • Research Labs
    • AI 阅读
    • AI 文库
    • 深度研究
    • 学者亮点
  • 学术资源
    • AI2000
    • 期刊/会议
    • 学者库
    • 学术API
      MCP&Skill
    • 溯源树
    • 数据集
  • 知识沉淀
    • 学术空间
订阅小程序
旧版功能
aminer vip
开通会员低至0.73元/天
一次搞定AI科研
立即登录
  • English
  • 联系方式
    Journal of Digital Imaging

    Journal of Digital Imaging

    JournalISSN 0897-1889eISSN 1618-727X中科院 工程技术 3区

    年发文量

    研究主题

    论文(4565)

    排序
    1Artificial Intelligence in Orthopedic Image Analysis: A Systematic Review and Unified Taxonomy of Bone Age Assessment and Fracture Detection
    Sumyia Sabrin Liza, Md Arham Tabib,Md. Hasan Imam Bijoy,Md. Zahid Hasan, Mohammad Rafiqul Islam Khan,Md Abdus Samad, Ohidujjaman

    Bone age assessment (BAA) and fracture detection are essential tasks in orthopedic radiography, since they aid diagnosis and clinical decision-making in trauma treatment. Recent technologies in artificial intelligence (AI), particularly deep learning (DL), have enhanced the ability to analyze radiological images with greater accuracy and consistency. However, current studies are incomplete, with inconsistent evaluation methodologies, limited external validation, and insufficient interpretability, limiting clinical implementation. This study provides a systematic PRISMA-based review of 116 studies (2017–2025) that analyze imaging modalities, datasets, model architectures, evaluation techniques, and clinical relevance. A uniform taxonomy is introduced to define techniques based on task, modality, and learning paradigm, along with a comparative methodology to address inconsistencies across studies. The findings indicate that CNN and transformer-based models achieve MAE as low as 0.4–0.7 years and accuracy exceeding 95

    2026
    引用
    AI阅读
    加入学术空间
    2Evaluation Design and Model Selection Stability in Medical Image Classification Benchmarks: A Multi-dataset Study
    Feng Shi, Qiang Li, Jiansheng Qi, Pei Xu

    Medical image classification benchmarks inform model selection. We assessed how data splits, training seeds, and evaluation conditions affect selection stability and whether repeated evaluation budgets support reproducible rankings. The original study comprised 800 runs on OrganAMNIST and SIPaKMeD, using four ImageNet-initialized convolutional neural networks (CNNs), ten splits, five seeds, and two checkpoint selection and stopping procedures. The 300-run extension evaluated the International Skin Imaging Collaboration (ISIC) 2019 challenge dataset and MURA (musculoskeletal radiographs) using four CNNs, ten splits, and three seeds under procedure A; paired Swin Transformer-Tiny (Swin-T) analyses used five splits and three seeds. Balanced accuracy (BA) defined rankings. Paired resampling quantified selection frequencies and uncertainty; budget analyses compared discovery subsets with held-out splits. Single-context agreement with the full repeated evaluation reference was 44–62

    2026
    引用
    AI阅读
    加入学术空间
    3EDGE-Net: Enhanced Distribution Gated Eye-Vessel Network for Ophthalmic Vascular Segmentation with Topological Constraints
    Xuesheng Bian, Sihao Wang, Leyi Mei, Chaoshen Xiao, Fan Yang,Hong Jia,Weiquan Liu

    Ophthalmic vascular segmentation supports quantitative analysis of the retinal vasculature, yet thin vessels, low contrast, and complex vascular topology remain challenging. We propose EDGE-Net (Enhanced Distribution Gated Eye-vessel Network), which combines the CLARITY preprocessing pipeline, a Dynamic Dual-Stream Attention Block (DDSAB), Multi-Stream Gated Feature Fusion (MSGFF), and topology-aware loss terms based on persistent homology and connectivity regularization. The framework is evaluated on three retinal vessel datasets (DRIVE, CHASE_DB1, and STARE) and two coronary angiography datasets (DCA1 and CHUAC); all hyperparameters are selected on a DRIVE validation split and then fixed for every dataset. EDGE-Net obtains the highest F1 score on all five datasets, ranging from 0.8394 to 0.8456 on the retinal datasets and from 0.7421 to 0.7518 on the coronary datasets, although it does not achieve the highest accuracy or specificity on every dataset. When the same dual-threshold iterative (DTI) post-processing is applied to every method on DRIVE, EDGE-Net obtains the lowest Vessel Connectivity Assessment score (3.31 versus 3.58 for the strongest competitor) and the highest Junction Preservation Rate (0.842 versus 0.812); both differences are significant after Holm correction (paired Wilcoxon signed-rank test, p<0.01 ). A controlled ablation attributes most of the pixel-level gain to DDSAB and MSGFF and most of the junction-preservation gain to the topology loss. Potential downstream uses include anatomically plausible vascular-network analysis; direct clinical benefit is not evaluated in this study.

    2026
    引用
    AI阅读
    加入学术空间
    4An Interpretable Multimodal Deep Learning Framework Integrating MRI and Clinical Data Via Bidirectional Cross-Modal Attention for Improved Cardiac Disease Detection
    Monerah Abdulrahman M. Almohideb, Faten Almohideb, Basmah Altuwayjiri, Rani Ahmad,Mozdalifah Elnaeem, Muhannad Faleh Alanazi, Sameer Ali Bafaqeeh,Bandar Saad Alshreef

    Cardiovascular diseases continue to be the primary cause of mortality worldwide; however, precise diagnosis is often limited by dependence on individual data modalities and the unclear nature of traditional deep learning models. In this study, we introduce an explainable multimodal deep learning framework that simultaneously analyzes cardiac magnetic resonance imaging (MRI) and structured clinical variables through a bidirectional cross-modal attention mechanism that operates on token sequences. The architecture utilizes modality-specific encoders ResNet-50 for imaging and a multilayer perceptron for clinical data interconnected through attention that dynamically aligns complementary information, reducing feature dilution and modal dominance. A multitask objective that includes classification, contrastive alignment (InfoNCE), and regularization further reinforces semantic consistency across modalities. Integrated post hoc explainability modules, such as Gradient-weighted Class Activation Mapping for spatial localization and SHapley Additive exPlanations for clinical feature attribution, offer transparent decision support. Tested on a cohort of 12,847 patients using fivefold cross-validation, the framework achieved an accuracy of 94.2

    2026
    引用
    AI阅读
    加入学术空间
    5CASSFormer: A Lightweight CNN-Transformer Hybrid Network for Real-Time Coronary Artery Stenosis Detection and Localization
    Pengju Wang, Junqi Jiang, Shuangqingyue Zhang,Shuhuan Wang, Ya Zhang, Zhijian Qi,Shuang Liu,He Ma

    Coronary angiography (CAG) is the clinical gold standard for assessing coronary artery stenosis. However, its two-dimensional projection nature often causes vessel overlap and limited contrast, making subtle or complex stenotic regions difficult to detect and localize, thereby increasing reliance on experienced cardiologists. Existing deep learning methods face a practical trade-off: CNN-based models struggle with low-contrast or small-scale lesions, while Transformer-based models incur high computational cost, limiting real-time applicability. To address these challenges, we propose Coronary Angiography Structure-aware Stenosis Transformer (CASSFormer), a lightweight CNN-Transformer hybrid network for real-time coronary artery stenosis detection and localization. Specifically, CASSFormer integrates three key components: (i) a multi-stage spatial feature downsampling module (MSFD) to preserve fine-grained vascular textures during early feature extraction; (ii) a multi-scale mixed-topology block (MMTB) to model elongated vessel structures and multi-scale stenotic patterns; (iii) a dual-attention cross-scale adaptive fusion module (DCAF) that jointly exploits local directional attention and global channel attention to enhance sensitivity to low-contrast and small-scale stenotic regions. Experiments on a large private clinical dataset and two public datasets (ARCADE, ADSD) show that CASSFormer achieves favorable detection and localization performance compared with mainstream detection models, while maintaining low computational overhead (27.1 GFLOPs, 11.9M parameters) and an average inference time of 8.0 ms per image. Visualization results further suggest its robustness under challenging angiographic conditions, including vessel overlap, distal small vessels, and severe stenosis or vessel interruption associated with myocardial infarction. These results support CASSFormer as an efficient assistive tool for stenosis detection and localization in complex CAG scenarios.

    2026
    引用
    AI阅读
    加入学术空间
    立即登录,查看全部 4565 篇论文

    高被引作者

    作者引用发文
    Fred W. Prior634512
    Justin S Kirby61882
    John Freymann61882
    Paul Koppel61774
    Kenneth W. Clark61637
    Stephen M. Moore61626
    David R. Maffitt61523
    Vendt Bruce A61413
    Lawrence Tarbox61293
    Kirk Smith61041

    高产作者

    作者引用发文
    Bruce I. Reiner129476
    Erickson Bradley J302773
    Eliot Siegel119057
    Steve Langer72245
    Katherine P. Andriole103941
    Elizabeth Krupinski98740
    Paul Nagy71138
    Tessa S. Cook56729
    Charles E. Kahn46829
    Kwang Gi Kim26726

    相关期刊

    BMC Medical Imaging
    Computerized Medical Imaging and Graphics
    International Journal Of Imaging Systems And Technology
    Medical Image Analysis
    Radiology. Artificial intelligence
    Current medical imaging
    Medical Physics
    Journal of X-Ray Science and Technology
    Physical and Engineering Sciences in Medicine
    Radiology: Artificial Intelligence