• 学术搜索
  • 科研智能体
    • Research Labs
    • AI 阅读
    • AI 文库
    • 深度研究
    • 学者亮点
  • 学术资源
    • AI2000
    • 期刊/会议
    • 学者库
    • 学术API
      MCP&Skill
    • 溯源树
    • 数据集
  • 知识沉淀
    • 学术空间
订阅小程序
旧版功能
aminer vip
开通会员低至0.73元/天
一次搞定AI科研
立即登录
  • English
  • 联系方式
    Biomedical engineering online

    Biomedical engineering online

    JournalISSN 1475-925XeISSN 1475-925X中科院 医学 4区

    年发文量

    研究主题

    论文(2622)

    排序
    1Evaluation of Bone-Conducted Sound During Ear Surgery: an in Vivo Pilot Study
    Katarina Gille,Mario Fleischer,Marcus Neudert,Thomas Zahnert,Matthias Bornitz

    The impact of noise induced by drilling on hearing during ear operations has been discussed several times in the past. However, direct measurements of the equivalent sound pressure level in patients undergoing ear surgery have not previously been reported. This pilot study presents an easy-to-use method based on a calibrated accelerometer to determine the equivalent sound pressure level potentially applicable in the clinical routine. During seven monitored cochlear implant surgeries, the equivalent A-weighted sound pressure level LAF ranged from 111 to 126 dB(A)eqSPL at its maximum, whereas C-weighted peak levels LCpeak showed peaks up to 140 dB(C)eqSPL. The recommended daily noise exposure limit was exceeded for three of the seven patients, suggesting the potential for drilling-induced temporal shifts in hearing threshold. Based on these findings, standardized noise monitoring is recommended as a quality assurance measure during otological surgery.

    2026
    引用
    AI阅读
    加入学术空间
    2Design of Flexible Wideband Wearable Antenna Integrated with Textile FSS for ISM and 5G Biomedical Applications
    A. L. Sharon Giftsy,Usha Kiran Kommuri

    The biomedical technology requires compact and wideband wearable antennas to ensure reliable wireless transmission of physiological large data for continuous health monitoring and biomedical telemetry. To meet these requirements, a unique modified hexagonal radiator incorporated with slots and stub which perturb the current paths to offer multiple resonances. Together, these frequencies combined to form wideband behavior from 1.95 to 7.45 GHz that includes 5G band and ISM band range which is appropriate for biomedical applications. EVA foam is utilized as the substrate in the proposed antenna for wearer comfort and flexibility, which has an antenna dimension of 48 × 36 × 1.7 mm3. The wideband operation over the frequency achieves a fractional bandwidth of 117

    2026
    引用
    AI阅读
    加入学术空间
    3Safety and Feasibility of Transvascular Pulsedfield Ablation for Orthotopic Liver Tumor in a Rabbit Model
    Linbiao Xiang, Xi Zhang,Shuqin Xu,Minge Wu,Jiawei Yu, Zhenwei Yang,Hu Chen,Qiang Lu, Ju Zhang, Guantong Fang,Yi Lyu,Nana Zhang

    Local ablation is a cornerstone of hepatocellular carcinoma management. However, thermal techniques are unsuitable for perivascular tumors due to the heat-sink effect and risk of injury to adjacent critical structures. While non-thermal pulsedfield ablation (PFA) overcomes these limitations, its percutaneous needle-based delivery risks tract seeding and potential vascular injury. This study evaluates a novel transvascular PFA approach using intravascularly delivered electrodes. By circumventing percutaneous needle-based electrode insertion, this strategy may reduce puncture-related complications and enable the ablation of tumors adjacent to major vessels. A custom endovascular PFA electrode was developed. Candidate treatment parameters were selected based on computational modeling. Subsequent transvascular PFA was performed in healthy rabbits with electrodes in the portal vein and inferior vena cava, assessing safety and histology over 28 days. The feasibility of tumor ablation was then evaluated in a rabbit VX2 orthotopic liver tumor model. Based on simulations, a protocol of 800 V (corresponding to an electric field strength of 1000 V/cm across the 8-mm electrode gap) and 80 pulses was selected, at which the modeled field between electrodes exceeded a conservative irreversible electroporation threshold (600 V/cm) without predictive thermal injury. In vivo, the procedure caused no persistent alterations in vital signs. Histopathological analysis showed coagulative necrosis of the targeted liver parenchyma and extensive necrosis of VX2 tumor tissue within the ablation zone, followed by a characteristic inflammatory and fibrotic repair response. Although the perivascular parenchyma was ablated, the structural architecture of the portal vein and inferior vena cava was preserved. Re-endothelialization was evident by day 21. Apart from a transient surgery-related fibrinogen elevation, coagulation parameters showed no PFA-specific changes under perioperative anticoagulant and postoperative antiplatelet therapy. No vascular perforation, acute occlusion, or ablation-related hemorrhage occurred in any animal. Transvascular PFA achieved effective ablation of liver tissue and transplanted VX2 liver tumors adjacent to major vessels while preserving vascular architecture, without evidence of significant thermal injury and major vascular injury-related complication. These preliminary findings suggest that transvascular PFA is promising and innovative, yet further investigation is warranted for high-risk anatomical tumors.

    2026
    引用
    AI阅读
    加入学术空间
    4Electron Microscopy Characterization of Ultrastructural Alterations Induced by Reversible and Irreversible Electroporation
    Wenyuan Ma, Lei Xu, Chengyue Zhang, Fan Xu,Wenjing Lou, Haoyu Liu,Liting Xie,Tian’an Jiang

    Electroporation produces reversible or irreversible plasma membrane permeabilization depending on pulse parameters and biological context. However, direct comparisons of membrane and organelle ultrastructure after reversible electroporation (RE) and irreversible electroporation (IRE) remain limited. This study characterized their multilevel structural effects in tumor cells and porcine tissues. KPC pancreatic cancer cells and Hepa1-6 hepatocellular carcinoma cells were treated with 60 pulses of 90 μs at 750 V/cm (operational RE) or 1,250 V/cm (operational IRE). Transmission electron microscopy (TEM) was used to examine mitochondrial and endoplasmic reticulum morphology, whereas scanning electron microscopy (SEM) and free-fluorescein isothiocyanate uptake were used to assess cell surface morphology and membrane permeability. Candidate nanopores were operationally identified using control-derived diameter thresholds and analyzed by Gaussian mixture modeling. Porcine liver and pancreas from animals were examined 24 h after IRE. RE was associated with mitochondrial contraction, increased matrix density, reduced cristae, and limited endoplasmic reticulum dilation. IRE caused extensive mitochondrial and endoplasmic reticulum swelling, cristae disruption, membrane fragmentation, increased FITC uptake, and numerous membrane surface depressions. IRE shifted the median depression diameter from 28 to 48 nm in KPC cells and from 30 to 111 nm in Hepa1-6 cells (Holm-adjusted P < 0.001). Candidate-nanopore diameters showed cell line-specific non-unimodal distributions, with fitted components centered at approximately 91 and 262 nm in KPC cells and 101, 199, and 369 nm in Hepa1-6 cells. Related tissue surface alterations and pore-like erythrocyte membrane discontinuities were observed in porcine liver and pancreas. Microsecond electroporation produced a graded ultrastructural response, ranging from limited organelle alterations after RE to extensive membrane and organelle disruption after IRE. These findings establish a structural framework for future mechanistic studies and pulse-parameter optimization.

    2026
    引用
    AI阅读
    加入学术空间
    5Prescription-aware Diffusion Transformer for Esophageal VMAT Dose Prediction: a Retrospective Dual-Center Validation and Target-Level Analysis
    Jiacheng Guo, Yue Wang, Xiaoyun Huang, Liu Wang, Qinmei Liao, Jinwei Hu, Xihao Hu, Xiaojia Yu,Qiang Yuan,Wenjing He,Yuanzhong Zhu, Hong Deng

    Deep learning-based radiotherapy dose prediction has the potential to support automated treatment planning and plan-quality assessment; however, simultaneous integrated boost (SIB) volumetric modulated arc therapy (VMAT) for esophageal cancer remains challenging because multiple target levels are associated with different prescription doses and complex spatial relationships. We developed a prescription-aware diffusion Transformer framework for esophageal VMAT dose prediction and evaluated voxel-wise prediction accuracy, prescription-specific target behavior, and target-integrity sensitivity in a dual-center cohort. The global MAE within the body/union PTV MAE of DoseDiT was 3.15/4.79 Gy in the validation set, 3.07/4.99 Gy in the internal test set, and 4.25/7.47 Gy in the external test set. Target-level analysis revealed a systematic prescription-dependent bias, characterized primarily by persistent underestimation of D95/Rx for Boost targets in both the internal and external cohorts. After RxMap ablation, the PTV MAE increased to 5.35 Gy internally and 8.17 Gy externally, supporting the value of voxel-wise prescription representation for modeling complex target-dose distributions. GlobalPSDM provided no additional accuracy gain, whereas the MMFNet baseline under matched settings achieved lower errors. These findings indicate that the principal value of this study lies in prescription-aware representation and target-level error characterization. The voxel-wise RxMap provides local prescription-level information for SIB treatment plans, with its contribution concentrated primarily within target regions. Target-level analysis further demonstrated a systematic prescription-dependent coverage bias, with underestimation of Boost coverage showing good reproducibility in both the internal and external cohorts. GlobalPSDM did not provide an additional prediction-accuracy gain in the current implementation, whereas the matched MMFNet baseline achieved lower values for the major error metrics. These findings indicate that heterogeneous-prescription dose prediction should consider local prescription representation, target-level evaluation, and cross-center model robustness simultaneously. The current DoseDiT can serve as a research-oriented dose prior and analytical framework; further clinical translation will require three-dimensional or physics-aware modeling and prospective multicenter validation.

    2026
    引用
    AI阅读
    加入学术空间
    立即登录,查看全部 2622 篇论文

    高被引作者

    作者引用发文
    Thomas A. Pologruto15891
    Karel Svoboda15891
    Bernardo Sabatini15891
    Maureen Clerc14983
    Alexandre Gramfort14761
    Emmanuel Olivi14761
    Théo Papadopoulo14761
    J. Geoffrey Chase129231
    Damijan Miklavčič124915
    Robert Koprowski115930

    高产作者

    作者引用发文
    J. Geoffrey Chase129231
    Robert Koprowski115930
    Thomas Desaive113324
    Geoff Shaw94818
    Max E Valentinuzzi50716
    Edward J. Ciaccio39215
    Damijan Miklavčič124915
    Zygmunt Wrobel43914
    Milos Popovic34213
    Yuanyuan Wang23413

    相关期刊

    Medical & Biological Engineering & Computing
    Medical Engineering & Physics
    Biomedical Engineering Letters
    Biomedical physics & engineering express
    Bioengineering (Basel, Switzerland)
    Annals of Biomedical Engineering
    Journal of Medical and Biological Engineering
    Biomedizinische Technik
    Technology and Health Care
    Medicine in Novel Technology and Devices