
Radiology is a relatively high-cost and high-maintenance aspect of medicine. Expertise is constantly required, from acquisition to its use and quality assurance programmes. However, it is an integral part of healthcare practice, from disease diagnosis, surveillance and prevention to treatment monitoring. It is alarming that two thirds of the world is deficient in or lacks even basic diagnostic imaging. Developing and underdeveloped countries need help in improving medical imaging. Help is coming from various organisations, which are extending hands-on teaching and imparting knowledge, as well as training trainers to increase the pool of skilled practitioners in the use of imaging equipment and other aspects of radiology services. The scene for social radiology is changing and set to positively impact the world in the (near) future.
OBJECTIVES:This review was aimed at determining the imaging findings in patients with precocious puberty.RESULTS:Within a period of 8 years (from 2002 to 2010) there were 53 patients diagnosed with precocious puberty. Out of the 53 patients, 37 had undergone diagnostic imaging to detect the possible organic causes of precocious puberty. Imaging findings were positive in 31 patients and out of that, 3 patients had 2 findings each (34 abnormalities). Of the patients with positive imaging findings, central precocious puberty (gonadotrophin-dependent) was more common (81%; 25/31) and the causes included: tuber cinereum hamartoma (n = 10), glioma (n = 6), pineal gland tumour (n = 4), hydrocephalous (n = 3), arachnoid cyst (n = 2) and others (n = 3). Peripheral precocious puberty (gonadotrophin-independent) causes included: testicular adrenal rest tumour (n = 3), adrenal carcinoma (n = 1), ovarian granulosa thecal cell tumour (n = 1), and tuberous sclerosis (n = 1).CONCLUSION:Positive imaging findings were observed in 84% (31/37) of the subjects. Hypothalamic hamartoma was the most common imaging finding in central precocious puberty while testicular adrenal rest tumour was the most common imaging finding in peripheral precocious puberty.
PURPOSE:To evaluate the performance of 2D-array I'mRT MatriXX for dose verification of TomoDirect treatment plans.METHODS:In this study, a 2D-array ion chamber device - the I'mRT MatriXX and Multicube Phantom from IBA - was used for dose verification of different TomoDirect plans. Pre-treatment megavoltage computed tomography (MVCT) was performed on the phantom setup for position correction. After the irradiation of treatment plans on the I'mRT MatriXX and Multicube Phantom, the measured doses of coronal planes were compared with those from the planning calculations for verification. The results were evaluated by comparing the absolute dose difference in the high dose region as well as the gamma analysis of the 2D-dose distributions on the coronal plane. The comparison was then repeated with the measured dose corrected for angular dependence of the MatriXX.RESULTS:When angular dependence is taken into account, the passing rate of gamma analysis is over 90% for all measurements using the MatriXX. If there is no angular dependence correction, the passing rate of gamma analysis worsens for treatment plans with dose contribution from the rear. The passing rate can be as low as 53.55% in extreme cases, i.e. where all doses in the treatment plan are delivered from the rear.CONCLUSION:It is important to correct the measured dose for angular dependence when verifying TomoDirect treatment plans using the MatriXX. If left uncorrected, a large dose discrepancy may be introduced to the verification results.
To investigate whether the multislice CT scanning protocols of head, chest and abdomen are adjusted according to patient's age in paediatric patients.Multislice CT examination records of paediatric patients undergoing head, chest and abdomen scans from three public hospitals during a one-year period were retrospectively reviewed. Patients were categorised into the following age groups: under 4 years, 5-8 years, 9-12 years and 13-16 years, while the tube current was classified into the following ranges: < 49 mA, 50-99 mA, 100-149 mA, 150-199 mA, > 200 mA and unknown.A total of 4998 patient records, comprising a combination of head, chest and abdomen CT scans, were assessed, with head CT scans representing nearly half of the total scans. Age-based adjusted CT protocols were observed in most of the scans with higher tube current setting being used with increasing age. However, a high tube current (150-199 mA) was still used in younger patients (0-8 years) undergoing head CT scans. In one hospital, CT protocols remained constant across all age groups, indicating potential overexposure to the patients.This analysis shows that paediatric CT scans are adjusted according to the patient's age in most of the routine CT examinations. This indicates increased awareness regarding radiation risks associated with CT. However, high tube current settings are still used in younger patient groups, thus, optimisation of paediatric CT protocols and implementation of current guidelines, such as age-and weight-based scanning, should be recommended in daily practice.
A 69 year-old man presented with an incidental finding on radiograph of a lesion in the left upper lobe. CT indicated it was likely to be a neoplasm and CT-guided FNA was requested. The lesion was located medial to the scapula so a creative approach was utilised to gain access to the lesion. This study discusses the approach used and why it reduced patient risk compared to a more conventional procedure. The sample was positive for neoplasm and there were no complications arising from the procedure.
Fibrin sheath formation around long-term haemodialysis catheter is a common cause of failed dialysis access. Treatment options include pharmacological and mechanical methods. This paper reports a case of failed dialysis access due to fibrin sheath encasement. Pharmacologic thrombolysis, mechanical disruption using guide wire and catheter exchange had failed to address the issue. Eventually, fibrin sheath stripping using the loop snare technique was able to successfully restore the catheter function.
Diagnosing acute appendicitis in children can be difficult due to atypical presenting symptoms. While there are reported cases of acute appendicitis or appendiceal masses causing unilateral hydronephrosis, bilateral hydronephrosis as a complication of appendiceal mass is very rare. We report a case of a child who presented with cardinal symptomatology associated with the urogenital tract. Ultrasound (US) investigation showed a pelvic mass causing bilateral hydronephrosis. An initial diagnosis of a pelvic teratoma was made based on the US and computed tomography (CT) scan findings. The final diagnosis of an appendiceal mass causing bilateral hydronephrosis was established intraoperatively.
It was the aim of this work to assess and track the workload, working conditions and professional recognition of radiation oncology medical physicists (ROMPs) in the Asia Pacific region over time. In this third survey since 2008, a structured questionnaire was mailed in 2014 to 22 senior medical physicists representing 23 countries. As in previous surveys the questionnaire covered seven themes: 1 education, training and professional certification, 2 staffing, 3 typical tasks, 4 professional organisations, 5 resources, 6 research and teaching, and 7 job satisfaction. The response rate of 100 % is a result of performing a survey through a network, which allows easy follow-up. The replies cover 4841 ROMPs in 23 countries. Compared to 2008, the number of medical physicists in many countries has doubled. However, the number of experienced ROMPs compared to the overall workforce is still small, especially in low and middle income countries. The increase in staff is matched by a similar increase in the number of treatment units over the years. Furthermore, the number of countries using complex techniques (IMRT, IGRT) or installing high end equipment (tomotherapy, robotic linear accelerators) is increasing. Overall, ROMPs still feel generally overworked and the professional recognition, while varying widely, appears to be improving only slightly. Radiation oncology medical physics practice has not changed significantly over the last 6 years in the Asia Pacific Region even if the number of physicists and the number and complexity of treatment techniques and technologies have increased dramatically.
OBJECTIVE:To evaluate the patterns of pulmonary venous drainage into the left atrium and to determine the frequency of each variant of pulmonary venous anatomy.MATERIALS AND METHODS:After institutional review board approval (No. 09JUL011148), 300 studies of thoracic multidetector computed tomography were retrospectively reviewed for the anatomical features of the pulmonary vein and its drainage pattern into the left atrium. The percentage of each pattern was calculated.RESULTS:The anatomy of pulmonary venous drainage in 300 patients (150 male and 150 female, mean age 60.16 years) showed some variation. In the right pulmonary vein, the most common drainage pattern was two ostia (90.33%), followed by three to five ostia (6.33%) and a single ostium (3.33%). There were one or two separate middle lobe vein ostia in groups of more than two openings. On the left side, there were two patterns; a single venous ostium (59%) was much more common than two ostia (41%). In both right and left pulmonary veins, there were five cases (2 male, 3 female) that had a single pulmonary venous ostium, bilaterally. However, there were only 17 cases (5.67%), out of 300 enrolled in this study, that had bilateral pulmonary venous ostial variations.CONCLUSION:A classification system to succinctly describe pulmonary venous drainage patterns was developed. In left-sided drainage, a single left pulmonary ostium was the most common variation. The right-sided venous drainage varied more in both number and pattern than those of the left side; nevertheless, bilateral pulmonary venous ostial variation was not frequently found.
PURPOSE:To investigate the dosimetric accuracy of the sliding window gated IMRT compared with the static treatment, using varying dose rates.MATERIALS AND METHODS:This study measured changes in output and diode array response with changing dose rate, verified the precision of the motion table, and measured changes in dose distribution accuracy with film and diodes at two depths with changing dose rate. During 4DCT (4 Dimensional Computed Tomography), the patient's respiratory signals and target motion were recorded and imported to the XY4D simulation table of SUN NUCLEAR Corporation to simulate the patient's respiration and tumour motion. A single field of each sliding window IMRT plan with 30º wedge and one for lung cancer were used in this study. Three irradiating conditions, static and moving target with and without gating, were applied to both plans.RESULTS:The standard deviations of output, with the dose rates changing from 300-600 MU/min, were 0.065 cGy and 0.169 cGy for the ionisation chamber and diode, respectively. The verification of the motion table shows very good precision with 9.98 ± 0.02 cm (true value = 10.0 cm). The measurements by MapCheck show the gamma index of the planned absolute dose distribution in static and moving targets with gating, resulting in more than 96% passing for all dose rates. The absolute dose distribution measured by film for the static target was agreeable with the value of moving target with gating.CONCLUSION:The sliding window gated IMRT technique is able to deliver an accurate dose to a moving target with the dose rate of 300-600 MU/min that is suitable for clinical treatment.
PURPOSE:This fMRI study is about modelling the effective connectivity between Heschl's gyrus (HG) and the superior temporal gyrus (STG) in human primary auditory cortices. MATERIALS #ENTITYSTARTX00026;METHODS:Ten healthy male participants were required to listen to white noise stimuli during functional magnetic resonance imaging (fMRI) scans. Statistical parametric mapping (SPM) was used to generate individual and group brain activation maps. For input region determination, two intrinsic connectivity models comprising bilateral HG and STG were constructed using dynamic causal modelling (DCM). The models were estimated and inferred using DCM while Bayesian Model Selection (BMS) for group studies was used for model comparison and selection. Based on the winning model, six linear and six non-linear causal models were derived and were again estimated, inferred, and compared to obtain a model that best represents the effective connectivity between HG and the STG, balancing accuracy and complexity.RESULTS:Group results indicated significant asymmetrical activation (p(uncorr) < 0.001) in bilateral HG and STG. Model comparison results showed strong evidence of STG as the input centre. The winning model is preferred by 6 out of 10 participants. The results were supported by BMS results for group studies with the expected posterior probability, r = 0.7830 and exceedance probability, ϕ = 0.9823. One-sample t-tests performed on connection values obtained from the winning model indicated that the valid connections for the winning model are the unidirectional parallel connections from STG to bilateral HG (p < 0.05). Subsequent model comparison between linear and non-linear models using BMS prefers non-linear connection (r = 0.9160, ϕ = 1.000) from which the connectivity between STG and the ipsi- and contralateral HG is gated by the activity in STG itself.CONCLUSION:We are able to demonstrate that the effective connectivity between HG and STG while listening to white noise for the respective participants can be explained by a non-linear dynamic causal model with the activity in STG influencing the STG-HG connectivity non-linearly.
OBJECTIVE:To document the types of congenital renal anomalies detected in adulthood, the clinical presentation and complications of these renal anomalies, and the most useful imaging modality in detecting a renal anomaly. MATERIALS AND METHODS:This study was approved by the institutional review board and informed consent was waived. Between January 2007 and January 2011, the clinical data and imaging studies of 28 patients older than 18 years diagnosed with renal anomaly at the authors' institution were retrospectively reviewed. Renal anomalies in this study included only those with abnormality in position and in form. RESULTS:Of these 28 patients, 22 underwent imaging studies and their results constituted the material of this study. Of the 22 patients, 14 had horseshoe kidneys (HSK), four had crossed renal ectopia and four had malrotation. Sixteen patients were men and six were women. The patients ranged in age from 19 to 74 years (mean age 51.1 years). Clinical presentations were abdominal pain (13), fever (13), haematuria (4), palpable mass (2), asymptomatic (2), polyuria (1) dysuria (1), blurred vision (1), and headache with weakness of left extremities (1). Imaging studies included abdominal radiograph (15), intravenous pyelography (IVP) (8), retrograde pyelography (RP) (4), ultrasonography (US) (7), and computed tomography (CT) (9). Associated complications included urinary tract stones (17), urinary tract infection (16), hydronephrosis (12), and tumours (2). Abdominal radiograph suggested renal anomalies in nine out of 15 studies. IVP, RP, US and CT suggested anomalies in all patients who had these studies performed. However, CT was the best imaging modality to evaluate anatomy, function and complications of patients with renal anomalies. CONCLUSION:HSK was the most common renal anomaly, with abdominal pain and fever being the most common presentations. UTI and stones were the most common complications. IVP, RP, US and CT can be used to diagnose renal anomalies but CT is the best imaging modality to evaluate renal anatomy, function and its complications.
Hepatocellular carcinoma (HCC) is one of the most common cancers, which is mainly a concern in Southeast Asia. Apoptosis resistance in HCC is one of the significant factors for hepatocarcinogenesis and tumour progression. Recent advances of apoptosis resistance mechanisms in HCC could serve as potential targets for molecular imaging, which would be of considerable value to explore the molecular processes involved in HCC progression and to evaluate responses of certain anti-HCC therapies. Disruptions in the balance of anti-apoptotic and pro-apoptotic processes have been found to be involved in apoptosis resistance in HCC. Loss of response to death receptors, transformation of growth factor-β induced apoptosis, upregulation of anti-apoptotic Bcl-2 subgroup, as well as downregulation of pro-apoptotic Bax subgroup and BH3-only subgroup, are associated with apoptosis resistance in HCC. Mutation of p53 gene, dysregulation of NF-κB and survivin are also of interest because of their contribution to HCC development. In this review, the aim is to identify potential targets for molecular imaging of apoptosis resistance in HCC.
John Cameron has made significant contributions to the field of Medical Physics. His contributions encompassed research and development, technical developments and education. He had a particular interest in the education of medical physicists in developing countries. Structured clinical training is also an essential component of the professional development of a medical physicist. This paper considers aspects of the clinical training and education of medical physicists in South-East Asia and the challenges facing the profession in the region if it is to keep pace with the rapid increase in the amount and technical complexity of medical physics infrastructure in the region.