
ABSTRACT Coupled heat transfer processes play a crucial role in a wide range of engineering applications, particularly in heat exchange systems where thermal interactions between solid and fluid media significantly influence overall heat transfer performance. In the present study, a numerical investigation of conjugate heat transfer in a square inclined enclosure separated by a finite‐thickness heat‐conducting baffle was performed. Special attention was given to the influence of the enclosure inclination angle on the heat transfer intensity between cavities filled with hot and cold fluids. The inclination angle of the enclosure was varied from 0° to 360°. The governing Navier–Stokes and energy equations were discretized using the finite volume method. Natural convection within the fluid domains was modeled under the Boussinesq approximation. The numerical results revealed a pronounced dependence of the heat transfer characteristics on the inclination angle. The maximum average Nusselt number along the hot wall was observed at inclination angles of 30° and 180°. Enhanced convective circulation and increased flow velocities were identified for inclination angles of 30°, 45°, 60°, 120°, 135°, and 150°. In contrast, the variation of the average Nusselt number along the hot wall with inclination angle was less significant than that observed for the cold wall. For the cold wall, the minimum and maximum average Nusselt numbers were obtained at inclination angles of 330° and 270°, respectively. For the hot wall, the average Nusselt number ranged from 29.8 to 77.2, with the minimum and maximum values occurring at inclination angles of 300° and 90°, respectively. Differences between the maximum and minimum local Nusselt numbers on the hot and cold walls were attributed to variations in the thermal boundary layer thicknesses adjacent to the corresponding surfaces. Furthermore, the highest local Nusselt number on the hot wall was consistently observed in the upper region of the enclosure, indicating intensified convective heat transfer in this area.
We present a distributed-memory finite-element framework for large-scale incompressible fluid-structure interaction (FSI) based on a monolithic one-field fictitious-domain formulation. The velocity and pressure are defined on a fixed Eulerian background mesh and discretized using Taylor-Hood finite elements with quadratic velocity and linear pressure approximation, while the immersed solid is represented by an updated Lagrangian mesh. The resulting saddle-point systems are solved by preconditioned MINRES with a symmetric split preconditioner, which takes a block-Jacobi form in parallel. The method is assessed using two- and three-dimensional lid-driven-cavity benchmarks involving deformable discs, slabs, spheres, and cylinders. Serial-parallel comparisons, temporal and background-mesh refinement studies, and quantitative solid-motion measures support the numerical consistency of the implementation. Strong-scaling results are reported up to 256 MPI ranks in two dimensions and 512 MPI ranks in three dimensions. Matrix assembly scales well, whereas degradation of the block-Jacobi preconditioner is the main factor limiting linear-solver efficiency. Nevertheless, the parallel implementation substantially reduces wall-clock time and enables large three-dimensional monolithic FSI simulations that would be prohibitively expensive in serial.
This article develops seven- and eight-point low-dissipation nonlinear schemes within the weighted compact nonlinear scheme (WCNS) framework. The schemes incorporate an ENO-like (Essentially Non-Oscillatory) stencil-selection technique from TENO (Targeted ENO) schemes for midpoint variable interpolation. The smoothness measurement, serving as an explicit discontinuity detector, operates on only three-point substencils and avoids complex high-order local or global smoothness indicators. The high-order interpolation polynomial is constructed through an extension strategy: using a standard five-point scheme as the base, additional endpoints are incorporated in smooth regions, while the reconstruction reverts to the five-point scheme near discontinuities to promote nonlinear robustness. The eight-point scheme extends the seven-point formulation by introducing controlled downwind blending, further reducing dissipation in the high-wavenumber range at minimal additional computational cost. Benchmark tests involving strong shocks, fine-scale wave structures, and broadband turbulence demonstrate robust discontinuity-capturing behavior and improved high-wavenumber resolution relative to the WCNS-7 and WCNS-T5 baselines considered in this study.
Several 2D compressible vortex models, proposed in the literature to investigate vorticity dynamics or to assess the accuracy of numerical methods, are reviewed and reformulated with a common non-dimensional notation. Two vortex types may be distinguished, namely the zero-global circulation vortex and the finite-global circulation vortex, where the global circulation amounts to the circulation value around a far-field path enclosing the vortex core. Numerical experiments carried out on the convected and stationary vortex benchmark tests are analyzed to clarify the error dynamics during the flow evolution in time. It is shown that both classes of compressible vortex models are affected, on the long term, by a flow instability of acoustic type. It is then concluded that this classical problem may be used to assess the spatial accuracy of a numerical scheme, through a standard h-refinement approach, only with the necessary caution.
This paper develops a two-relaxation-time lattice Boltzmann method (TRT-LBM) framework for simulating electro-thermo-convection (ETC) driven by conduction-based charge transport in a two-dimensional sidewall-heated square cavity. The coupled flow, temperature, and charge density fields are resolved using the TRT-LBM, while the electric potential is computed via a fast Fourier transform (FFT) based Poisson solver with domain extension. Numerical validations under hydrostatic and convective conditions demonstrate strong agreement with analytical and literature results. Parametric studies on the conduction number (), Rayleigh number (), and ion mobility ratio () reveal that the electric field suppresses natural convection by modifying the structure and thickness of heterogeneous charge layers. In the ohmic regime, a lower leads to stronger suppression of flow and heat transfer. At low Rayleigh numbers, the coupling between the electric body force and buoyancy within the charge layer can even induce symmetric secondary vortices. Furthermore, heat transfer suppression initially becomes more pronounced but gradually stabilizes as increases, as indicated by the decreasing relative Nusselt number . Within the investigated parameter range, the strongest suppression occurs at and , where . When the ion mobility ratio deviates from unity, the asymmetry introduced by unequal ion mobilities significantly alters the flow structure and heat transfer performance. As increases from 0.5 to 2.0, the average Nusselt number decreases from 2.49 to 2.21, corresponding to a reduction of approximately .