The Winter School on Therapeutic Ultrasound held its biennial meeting at the Ecole de Physique des Houches in Les Houches, France from March 26-31, 2017. The program brought together a globally and scientifically diverse group of faculty, clinicians, and trainees with interest in elements of therapeutic ultrasound. The meeting agenda was composed of daily lectures on various topics of relevance, supplemented with evening seminars, excursions, and networking opportunities. In anticipation of the next edition of the Winter School expected in 2019, we are nearly reaching the half way point between offerings of this unique and specialized meeting. Thus, this meeting report offers a reflection on the 2017 Winter School with the intention of setting the stage for 2019. Reviewed within this report are the lectures, student presentation series, and evening seminars encompassed within meeting agenda. It is my hope that this resource will be utilized by investigators within the therapeutic ultrasound community considering attending the Winter School in 2019.
s from the International Society for Therapeutic Ultrasound Conference 2017 Nanjing, China. 31 May 02 June 2017 Published: 21 May 2018 Fig. 1 (abstract O1). 18FDPA714 PET scans (coregistered to MRI template) in two rats: A: Hippocampus uptake 24 hours after one sonication. B: Striatum uptake 10 days after six weekly sonications. C: Graph of % difference between sonicated ipsilateral and contralateral striatum and hippocampus regions for Groups 1, 2 and 3 Oral Presentations O1 Neuroinflammation after disrupting the blood brain barrier with pulsed focused ultrasound and microbubbles imaged by 18F-DPA714 PET and MRI Zsofia I. Kovacs, Georgios Z. Papadakis, Tsang-Wei Tu, Sanhita Sinharay, William C. Reid, Bobbi Lewis, Dima A. Hammoud, Joseph A. Frank National Institutes of Health, Bethesda, Maryland, United States Correspondence: Zsofia I. Kovacs Journal of Therapeutic Ultrasound 2018, 6(Suppl 1):O1 OBJECTIVES Blood brain barrier (BBB) disruption with MR-guided pulsed focused ultrasound (pFUS) and microbubbles (MB) has been advocated as a noninvasive adjuvant treatment for malignancies and neurodegenerative diseases. A sterile inflammatory reaction has been recently described in the brain as a result of pFUS+MB (Kovacs et al. 2016). However, one potential issue of weekly pFUS+MB treatments is the lack of data on the longterm effects on inflammation. The purpose of this study was to evaluate the effects of multiple weekly courses of pFUS+MB exposures in the rat brain using micro-Positron Emmision Tomography (PET) and 18F-DPA-714, a marker of translocator protein (TSPO) upregulation/microglial activation and an indication of neuroinflammation. METHODS Female rats were assigned to three different groups based on the number of weekly pFUS+MB: Group 1: pFUS+MB x1, PET scans performed 24 hours later (n=6) ; Group 2: pFUS +MB x2 with PET scans performed within 10 days after 2nd sonication (n=5) ; and Group 3: pFUS+MB x6 with PET scans performed 7-9 days later (n=5). The left striatum (str) and right hippocampus (hc) were targeted in all animals. 100 μl of MB (OptisonTM, GE Healthcare, Little Chalfont, UK) was administered intravenously over 1 minute starting 30 secs before pFUS. Acoustic energy was delivered to the brain using “BBB configuration function” based on algorithm reported (O’Reilly et al. 2012) to determine optimal acoustic pressure for BBB opening via 1.5f0 and 2.5f0 ultra harmonic acoustic emission detection for every single pulse (9 focal points, 120 sec/9 focal points – striatum, 120 sec/4 focal points – hippocampus) using an 825 kHz hydrophone with a single-element spherical FUS transducer (center frequency: 589.636 kHz; focal number: 0.8; aperture: 7.5 cm; RK-100, FUS Instruments, Toronto, Ontario, Canada). T2* map were created from multiecho gradient echo sequence at 3T (Achieva, Philips Healthcare, Andover, MA) through the rat brain with TE=7 msec, echo train length 5 and echo spacing 7 and Tr=1500 msec. T2* maps were created by fitting signal intensity at each voxel to a single exponential fit with in-house software and histogram analysis was performed on volume of interests (VOI). Static microPET/CT scans emission data was acquired 30-60 min after injection of 18F-DPA-714. VOIs were drawn in the targeted areas and uptake was compared to the contralateral unaffected side. Uptake values were normalized to cerebellum. © The Author(s). 2018 Open Access This artic International License (http://creativecommons reproduction in any medium, provided you g the Creative Commons license, and indicate if (http://creativecommons.org/publicdomain/ze RESULTS 18F-DPA-714 uptake was increased at the sonication sites in all locations (Fig. 1). The ratio of the percent increase in SUV between pFUS+MB treated striatum and hippocampus to contralateral side is depicted in graph (mean+/-SEM) clearly showing large increase in uptake for both regions compared to normal brain. The neuroinflammatory changes persisted for at least 14 days after 2 weekly sonications. The coefficient of variation for PET scans was <10%. This corresponded to Iba1 activation visible on histology. Figure 2 contains normalized histograms from VOI for Group 2 and Group 3 rats derived from pFUS+MB treated (ipsilateral) and contralateral brain that shows a shift to lower T2* values for sonicated regions. CONCLUSIONS Rats receiving pFUS+MB to open the BBB showed a clear upregulation of TSPO expression consistent with microglial activation/neuroinflammation, even after one sonication session. Histograms derived from T2* maps MRI clearly shows that sonication with BBB algorithm results in left shift in T2* values that would be consistent with hypointense voxels on T2*w MRI and abnormatilies on histolology. These preliminary results contradict current assumptions that the effects of pFUS+MB are confined primarily to the endothelium and vessel wall. Further assessment of the long-term effects of pFUS+MB is necessary before this approach can be widely implemented in clinical trials.
With the expanding applications of magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU), there is an urgent need for a convenient, reliable, and fast acoustic pressure field measurement method to aid treatment protocol design, ensure consistent and safe operation of the transducer, and facilitate regulatory approval of new techniques. Herein, we report a method for acoustic pressure field characterization of MR-HIFU systems with multi-element phased array transducers. This method integrates fiber-optic hydrophone measurements and electronic steering of the ultrasound beam with MRI-assisted HIFU focus alignment to the fiber tip.
To evaluate the effectiveness and feasibility of high-intensity focused ultrasound (HIFU) for the treatment of bone metastases.
BACKGROUND:Prostate cancer is frequently treated using external beam radiation therapy (EBRT). Prior to therapy, the prostate is commonly implanted with a small number of permanent fiducial markers used to monitor the position of the prostate during therapy. In the case of local cancer recurrence, high-intensity focused ultrasound (HIFU) provides a non-invasive salvage treatment option. However, the impact of the fiducial markers on HIFU treatment has not been thoroughly studied to date. The objective of this study was to experimentally investigate the effect of a single EBRT fiducial marker on the efficacy of HIFU treatment delivery using a tissue-mimicking material (TMM).METHODS:A TMM with the acoustic properties of the prostate was developed based on a polyacrylamide hydrogel containing bovine serum albumin. Each phantom was implanted with a cylindrical fiducial marker and then sonicated using a 3.3 MHz focused bowl HIFU transducer. Two sets of experiments were performed. In the first, a single lesion was created at different positions along either the anteroposterior or left-right axes relative to the marker. In the second, a larger ablation volume was created by raster scanning. The size and position of the ablated volume were assessed using a millimetre grid overlaid on the phantom.RESULTS:The impact of the marker on the position and size of the HIFU lesion was significant when the transducer focus was positioned within 7 mm anteriorly, 18 mm posteriorly or within 3 mm laterally of the marker. Beyond this, the generated lesion was not affected. When the focus was anterior to the marker, the lesion increased in size due to reflections. When the focus was posterior, the lesion decreased in size or was not present due to shadowing.CONCLUSIONS:The presence of an EBRT fiducial marker may result in an undertreated region beyond the marker due to reduced energy arriving at the focus, and an overtreated region in front of the marker due to reflections. Depending on the position of the targeted regions and the distribution of the markers, both effects may be undesirable and reduce treatment efficacy. Further work is necessary to investigate whether these results indicate the necessity to reconsider patient selection and treatment planning for prostate salvage HIFU after failed EBRT.