Rising outdoor temperatures degrade the performance of vapour-compression air-conditioning (VCAC) systems in tropical cities. This study quantifies the energy and exergy penalties for a 1.5 HP (1.12 kW) residential split unit in Lagos and Abuja, Nigeria, between 2001–2012 and 2013–2023, using hourly ERA5 dry-bulb temperature and relative humidity (201,600 hours per station). A real-fluid (CoolProp) cycle model with a pressure-ratio-dependent compressor efficiency, motor efficiency and fan power was applied to R22 and R410A, in both representative-equipment and controlled equal-parameter configurations. Component exergy destruction was obtained from closed exergy balances with the hourly ambient as dead state, and humidity was represented through an outdoor-air latent-load model. Statistical inference used years as replicates. In Lagos, annual-mean compressor COP fell by 0.90% (R22) and 1.01% (R410A) (Mann–Whitney p = 0.018; Mann–Kendall p < 0.005), and system COP including fans fell by 0.66–0.72%. In Abuja the declines (1.27–1.45%, or 0.91–1.00% for the system) were not statistically significant because of larger interannual variability. The largest monthly decline was in Lagos in March (2.85–3.24%). Including outdoor-air loads, annual electricity use rose by 20.0–21.0 kWh per unit in Lagos, 35.8–38.1% of it due to humidity, compared with 15.5–17.0% in Abuja. The evaporator accounted for 37–40% of exergy destruction, the condenser for 26–28%, the compressor for 24–26% and the expansion valve for 7–10%. Under identical operating conditions R410A had a COP about 5% lower than R22, so its in-service advantage arises from equipment design. The Heat Index is used as a climate-stress indicator, while dry-bulb temperature and humidity ratio are treated as the thermodynamic boundary conditions. These findings support climate-aware sizing and efficiency standards for cooling equipment in Nigerian cities.
This study experimentally investigates a water-to-water heat pump operating with pure R744 and R744/R290 mixtures (0-20% propane) for low-to-medium ΔT applications, corresponding to water temperature increases of 5–20 K at the gas cooler. COP, heating capacity, and optimal gas cooler pressure are evaluated with and without internal heat exchanger (IHX). Three approaches are adopted: in the first, the refrigerant charge is fixed at the R744 reference value with the IHX active; in the second, the same charge is used with the IHX bypassed, which limits tests to propane fractions ≤ 10% due to superheat constraints; in the third, the charge is optimized for the 85/15% and 80/20% w mixtures to match the superheat of the pure R744 baseline. With the IHX active, high R290 fractions (15-20%) increase COP by up to 21.6% compared to pure R744. Without IHX and with R290 up to 10%, COP gains reach 7%, while under optimized charge the 85/15% mixture provides no significant improvement, whereas the 80/20% mixture improves COP. COP is consistently higher with the IHX, confirming its beneficial role. Heating capacity decreases with increasing propane content, by up to 12% at fixed charge and up to 26% when the charge is adjusted to maintain comparable superheat. In transcritical conditions the optimal gas cooler pressure decreases with increasing R290 fraction: up to 10% it follows a nearly linear trend related to the reduction in mixture critical pressure, whereas at higher fractions it approaches the mixture critical pressure, allowing subcritical or near-critical operation.
The influence of sintering temperature on the structural, microstructural, magnetic, and magnetocaloric properties of La0.75Dy0.05Sr0.1Ba0.1MnO3 has been systematically investigated. Three samples were prepared via sol–gel route and subsequently sintered at 800 °C, 1000 °C, and 1200 °C. X–ray diffraction analysis revealed the coexistence of both rhombohedral R3¯c and orthorhombic Pnma phases in all investigated samples. The concentration of the coexisting structural phases seems to be highly dependent on sintering temperature. Sintering at 800 °C yields nanosized particles with an average particle size around 48 nm. The Curie temperature seems to decrease with increasing sintering temperature. Hysteresis loop at 4 K displays exchange bias effect for the nanosized specimen (sintered at 800 °C). Magnetocaloric measurements demonstrate a peculiar behavior for the nanosized sample, where the magnetic entropy change curve shows a broad plateau–like shape, extending over a wide temperature range and encompassing room temperature. This distinctive behavior is ascribed to its intrinsic magnetic nature, arising from the coexistence of two Curie temperatures, approximately at 220 and 305 K. Under an applied magnetic field of 2 T, this sample exhibits the highest relative cooling power (RCP), reaching approximately 107.64 J kg⁻¹. The broad temperature span of its magnetocaloric response, together with its high RCP value, highlights the potential of this specimen as a promising material for magnetic refrigeration applications near room temperature. Furthermore, theoretical composite calculations were performed to further promote the magnetocaloric response.
The output power of gas turbines (GT) is greatly affected by the ambient temperature, and inlet air cooling can improve thermal efficiency and output power. A numerical simulation of the heat and mass transfer in the air inlet spray precooling outside the GT air inlet filter was carried out. Based on the characteristics of the gas-liquid two-phase flow and thermal field, the influence of spray configurations on the cooling effect is comparatively analyzed. The results show that the flow straightening device effectively optimizes inlet flow uniformity. Compared with the co-flow spray mode, counter-flow arrangement provides wider droplet coverage and better heat and mass transfer. Nozzle number significantly affects droplet distribution: insufficient nozzles cause uneven coverage, while excessive nozzles trigger jet interference and reduce cooling efficiency. As spray distance increases, the cooling temperature drop rises rapidly at first and stabilizes beyond 2 m. Higher relative humidity weakens cooling capacity but hardly changes droplet spatial distribution. A preferable spray configuration including a flow straightening device, counter-flow spray, 42-nozzle array and 3 m spray distance is obtained in this work. This configuration achieves a maximum temperature drop of 9.53 °C under high-temperature conditions and 5.81 °C at conventional ambient temperatures (25–35 °C). Ambient temperature variation has negligible effects on droplet distribution, proving the proposed layout has good environmental adaptability. This study reveals the parameter coupling mechanism of GT inlet spray cooling, providing potential engineering design references.
A novel cooling cycle and its prototype structure were presented for a miniature open-cycle two-stage Joule-Thomson (JT) cryocooler. Meanwhile, a one-dimensional transient numerical model, covering full-process modules (i.e., gas sources, multi-stage heat exchangers, JT elements, and thermal load), was developed and validated against experimental results. Transient flow and heat transfer characteristics of the cryocooler were simulated and analyzed. Simulation results indicate that the main-stage heat transfer within the precooling-stage evaporator is relatively inefficient, and the cooling capacity transferred to the main stage is also relatively small. Furthermore, the outlet parameters of the gas sources significantly affect heat transfer efficiency and pressure distribution of the cryocooler. Consequently, key strategies for performance improvement are proposed, including enhancing heat transfer in the precooling-stage evaporator, and optimizing the flow rate ratio between stages and gas source parameters. Besides, the analyses of single-gas and dual-gas working fluids were also carried out. The simulated and experimental results indicate that the proposed two-stage JT cooler exhibits superior adaptability for rapid-cooling applications, which can meet the cooling requirements of mid-wave infrared detectors at 100 K and mid-to-long-wave infrared detectors at 80 K, respectively.