
To describe a standardised four-pillar reconstructive framework for conversion to total hip arthroplasty (THA) after failed subtrochanteric fracture fixation, and to report preliminary short- to mid-term clinical and radiological outcomes. We retrospectively reviewed patients aged > 60 years who underwent cementless conversion THA according to a four-pillar reconstructive framework for failed subtrochanteric fracture fixation between January 2017 and December 2024. All patients had previously been treated with an intramedullary nail. The framework addressed four predefined domains: distal axial and rotational fixation, joint stability, reconstruction of the trochanteric-abductor complex and preservation or restoration of medial cortical support. Clinical outcomes were assessed using the Harris Hip Score (HHS) and a visual analogue scale (VAS) for pain. Serial radiographs were reviewed for stem fixation, clinically relevant migration, healing at the subtrochanteric reconstruction site and cortical strut allograft behaviour where applicable. Fifteen patients constituted the final outcome-analysis cohort [mean age 72.7 years (SD 4.0); mean follow-up 23.7 months; median 24 months (IQR 18–30; range 12–36)]. A trochanteric grip plate was used in all patients, and a tibial cortical strut allograft was used in 9 of 15 patients in whom the operative report documented a relevant medial or anteromedial cortical deficiency. Mean operative time was 101 min (SD 30.5), and full weight-bearing was achieved at a mean of 6.8 weeks (SD 1.2). Mean HHS increased from 42 (SD 9) to 80 (SD 7), and mean VAS pain score decreased from 8.0 (SD 0.8) to 2.0 (SD 0.8). No stem showed clinically relevant subsidence (> 5 mm) or progressive radiolucent lines. One major postoperative complication, a pulmonary embolism requiring temporary intensive care unit admission, and two minor complications were documented; no patient in the final outcome cohort required reoperation or revision surgery during the available follow-up. Cementless conversion THA performed according to a four-pillar reconstructive framework was associated with favourable early clinical and radiological outcomes in this retrospective series. Larger prospective comparative studies with longer follow-up are required to determine whether this framework provides advantages over alternative reconstructive strategies. IV (retrospective case series; Oxford Centre for Evidence-Based Medicine 2011 Levels of Evidence).
Over 93 million people worldwide live with stroke sequelae. Surgery is an effective and safe approach to poststroke upper extremity spasticity, which is usually treated by botulinum toxin type A (BoNT-A) injections. Surgery is commonly restricted to the most severe patients, but no clinical trial has compared the outcomes of these procedures. A randomized, controlled, parallel-group clinical trial with 12-month follow-up was conducted in adults with poststroke upper extremity spasticity and eligibility for surgery, recruited from two third-level hospitals in southern Spain. The objective was to compare functional, hygienic, and pain outcomes and the effects on emotional status, quality of life, and care burden between surgery and BoNT-A. For continuous outcomes, mixed-effects generalized linear models were developed with fixed effects for group, time, and their interaction, adjusted for baseline, with a random intercept for each subject to account for within-patient correlation. For ordinal outcomes, mixed-effects cumulative-link models were used with a complementary log–log link function, adjusted for baseline. Significantly greater improvements in Fugl-Mayer and modified Ashworth spasticity scale scores and a significantly higher patient satisfaction rate were obtained in the surgery group (n = 21) than in the botulinum toxin (BoNT) group (n = 24). Unlike BoNT-A, surgery significantly reduced the care burden and 36-item Short Form Health Survey (SF-36)-assessed pain of patients. The treatments did not significantly differ in their impact on emotional status or overall quality of life. The postsurgery complication rate was 23.8
In vivo studies have shown that the posterior cruciate ligament (PCL) has different mechanical functions at high- and low-flexion angles. For example, native PCL fibers are under higher tension during high flexion than during low flexion. However, most studies have not focused on dividing the entire range of motion (ROM) into high- and low-flexion parts and assessed them separately. Thirty-two healthy participants (10 females and 22 males) were recruited from the local community. Magnetic resonance imaging (MRI) and computed tomography (CT) were performed to obtain the change in PCL length with the knee flexion angle (0°–130° at 10° intervals). As the knees were flexed across the full 0°–130° ROM, the end-to-end distance of the native PCL continuously increased, with no shortening. Length changes of the most isometric points (MIPs) of 0°–60° and 70°–130° were significantly smaller than those of the anatomical centers of the posteromedial bundle (PMB)/anterolateral bundle (ALB). The a-MIP-70-130/-0-60 avoids the pitfalls of both techniques: graft laxity (traditional isometry) and excessive strain (anatomical reconstruction). This dual benefit addresses a key limitation in PCL surgery: the graft's limited elastic modulus. III. Understanding the biomechanical role of native PCL can help replicate its function, thereby improving surgical outcomes (particularly for double-bundle reconstruction).
The use of distal locking screws in simple pertrochanteric fractures treated with short cephalomedullary nails is still debated. The present study aims to assess the biomechanical effect of distal locking in standardized simple two-part AO/OTA 31A1.2 pertrochanteric fracture model, focusing on construct stability and load transfer. A three-dimensional finite element model was created based on computed tomography of a fourth-generation composite femur. Five different configurations were considered: intact bone, immediate postoperative locked and unlocked constructs, and healed locked and unlocked models. The 2400-N axial force was applied to the femoral head to replicate maximum loads occurring in the single-leg stance phase. Interfragmentary angular displacement, implant micromotion, and mean and maximum non Mises stresses were measured in the fracture area, proximal metaphysis, and distal cortical region. Comparative analysis without inferential statistics was performed. Both the locked and unlocked configurations provided mechanical stability with minimal implant micromotion. In the immediate postoperative models, interfragmentary angular displacement was similar to the locked and unlocked configurations. Stress distribution in the fracture and proximal metaphyseal regions was similar for both fixation techniques. The major difference was noted in the distal diaphysis, where distal locking caused higher stress concentration at the entry and exit sites of the locking screw. In contrast, the unlocked arrangement had a more uniform load-transfer profile, similar to that of the intact femur. After fracture-healing simulation, differences between the two models attenuated, with the stress distribution gradually converging to that of the intact femur. According to a finite element analysis of a simple two-part AO/OTA 31A1.2 pertrochanteric fracture model, distal locking did not confer a significant biomechanical benefit to the stability of the construct under the applied load. However, distal locking affected the load transfer process by producing higher local stress concentrations in the distal femoral cortex. Further clinical research is needed to assess whether these biomechanical differences have clinical significance. Level V, mechanism-based reasoning (Oxford Centre for Evidence-Based Medicine 2011 Levels of Evidence).
Robotic-assisted total knee arthroplasty (TKA) has gained popularity over the last decade, with claimed advantages in implant positioning accuracy and soft-tissue balance. Whether these technical advantages translate into better clinical outcomes for patients remains debated. This investigation compared 1-year patient-reported outcomes between robotic-assisted and conventional TKA performed within the same institution but following structurally different surgical workflows. This quasi-randomised controlled trial enrolled patients who underwent primary TKA at the Department of Orthopaedic and Trauam Surgery of the Eifelklink St. Brigida (Simmerath, Germany) between 2022 and 2025. Group allocation was determined by surgeon assignment through the institutional digital scheduling system. All patients received the same implant (Smith Nephew Legion Genesis II, posterior-stabilised). Robotic-assisted procedures were performed using the CORI Robotic System (Smith Nephew, UK) following a four-dimensional personalised alignment workflow (coronal, sagittal, transversal and balancing) guided intraoperatively by the Knee Balancing Score (KBS). Conventional procedures followed a femur-first technique with adjusted mechanical alignment. Outcomes included WOMAC total and subscores, visual analogue scale (VAS), Tegner activity score and a dedicated functional questionnaire, all assessed at 1-year follow-up. A total of 845 patients were included (robotic-assisted: n = 390; conventional: n = 455). At 1-year, 383 and 445 patients completed follow-up, respectively. The two groups were comparable at baseline. The robotic-assisted cohort showed significantly better results across WOMAC and related subscales (P < 0.001), VAS (P < 0.001), Tegner (P < 0.001), functional and satisfaction items, including walking distance and knee stability. No difference was found in the use of walking aids. Robotic-assisted TKA was associated with superior functional and patient-reported outcomes at the 1-year follow-up. The clinical benefit observed is likely not attributable to robotic precision alone, but reflects the structured, personalised intraoperative workflow that robotic assistance enables. Trial Registry German Registry of Clinical Trials (ID DRKS00030614).