
Imidacloprid, metalaxyl, myclobutanil, propham, and thiabendazole have been simultaneously determined in strawberries, oranges, potatoes, pears, and melons by matrix solid-phase dispersion (MSPD) followed by liquid chromatography–atmospheric pressure chemical ionization–mass spectrometry (LC–APCI–MS) in positive-ion mode. The samples were homogenized with C8 bonded silica as MSPD sorbent, placed in a glass column, and eluted with dichloromethane. Chromatographic separation of the compounds was achieved on a reversed-phase LC column using a methanol–ammonium formate (50 mmol L–1) gradient as a mobile phase. Samples were screened by monitoring the protonated molecular ion at m/z 256 for imidacloprid, 280 for metalaxyl, 289 for myclobutanil, and 202 for thiabendazole, and the main fragment at m/z 138 for propham. Positive samples were confirmed by multiple-ion monitoring. The repeatability (<20%) and recovery (>57%) of the method were good, and limits of detection (<0.05 mg kg–1) were adequate.
The emission of M2X+ cluster ions in thermal ionization mass spectrometry when graphite is loaded on the heating filaments was studied. The emission model of non-reductive thermal ionization of graphite was preliminarily discussed and factors influencing the thermal emission of M2X+ ions were investigated. The results show that the intensities of M2X+ cluster ions are related to ionic radius and crystal lattice energy, and possibly also to the solvation energies of ions. The intensities of M2Cl+ (M stands for K, Rb, and Cs) cluster ions, the M2Cl+/M+ ratios, and the 37Cl/35Cl ratios determined from M2Cl+ ion measurement usually increase with measurement time. The variation of the 37Cl/35Cl ratios determined from Cs2Cl+ ion measurement is lower than those based on K2Cl+ and Rb2Cl+ ion measurement, indicating the lowest isotopic fractionation.
The fabrication of microarrays containing PCR-amplified genomic DNA extracts from mice tumors on a Zetaprobe membrane using a modified thermal ink-jet printer is described. A simple and cost-effective procedure for the fabrication of microarrays containing biological samples using a modified bubble-jet printing system is presented. Because of their mass-produced design, ink-jet printers are a much cheaper alternative to conventional spotting techniques. The usefulness of the biochip microarray platform is illustrated by the detection of human fragile histidine triad (FHIT), a tumor suppressor gene. Subcutaneous carcinomas were induced with MKN/FHIT and MKN/E4 cell lines in immunodeficient mice. Several weeks into their development, the tumors from both groups of mice were removed and subjected to DNA extraction by lysis of tissue samples. The extracted DNA samples were amplified by PCR (30 cycles) using the primers corresponding to nucleotides 2 to 18 of the FHIT sequence. The resulting solution was transferred to the individual reservoirs of a three-color cartridge from a conventional thermal ink-jet printer (HP 694C), and arrays were printed on to a Zetaprobe membrane. After spotting, these membranes were used in a hybridization assay, using fluorescent probes, and detected with a biochip.
Micro flow modules with optical detection have been fabricated in a way which enables optical waveguiding inside and a defined interaction length along the fluid channel. Because of the usually lower refractive index of the solution compared with that of the substrate, so-called "leaky" optical wave-guiding must be employed. The combination of the fluid flow channel function with that of the optical waveguide has advantages for all miniaturized optical detection cells. It has been shown for hyper Rayleigh scattering (HRS) that improvement of the analytical principle is inherent in the miniaturization. The detection limit can be enhanced by at least a factor of 20. The applied HRS measurement procedure also enables simultaneous detection of two photon absorption (TPA) fluorescence. The severe boundary conditions of capillary electrophoresis were used as micro flow module design constraints to enable the transfer of the approach to other types of analysis.
Fundamentals of derivative hydride-generation atomic absorption spectrometry (DHGAAS) are described. A linear relationship was obtained between the derivative absorbance and the concentration of analysis in a sample. The new DHGAAS method was applied to the determination of traces of lead in water. The conditions affecting the derivative absorbance of lead were evaluated and optimized. The detection limit and sensitivity of the proposed method were 26 times and 8.8 times better, respectively, than those of conventional hydride-genera-tion atomic absorption spectrometry. The characteristic concentration (for a derivative absorbance of 0.0044) and detection limit (3sigma) for lead were 0.017 and 0.096 ng mL(-1), respectively, for a 2 mV min(-1) sensitivity range setting. The recovery range was 92.5-103%.
Five modifiers were tested for the direct determination of cobalt in coal fly ash and slag by ultrasonic slurry-sampling electrothermal atomic absorption spectrometry (USS–ETAAS).The furnace temperature programs and the appropriate amount for each modifier were optimized to get the highest signal and the best separation between the atomic and background signals. Nitric acid (0.5% v/v) was the most adequate chemical modifier for cobalt determination, selecting 1450 °C and 2100 °C as pyrolysis and atomization temperatures, respectively. This modifier also acts as liquid medium for the slurry simplifying the procedure. The remaining modifiers enhanced the background signal, totally overlapped with cobalt peak. The method optimized gave a limit of detection of 0.36 µg g–1, a characteristic mass of 13±1 pg and an overall-method precision which is highly satisfactory (<7%, RSD). The method was validated by analyzing two certified coal fly ash materials, and satisfactory recoveries were obtained (83–90%) and no statistical differences were observed between the experimental and the certified cobalt concentrations. Additionally, certified sediment, soil and urban particulate matter were assayed; again good results were obtained. The developed methodology was used to determine cobalt in several coal combustion residues from five Spanish power plants.
Disposable electrochemical DNA-based biosensors are reviewed; they have been used for the determination of low-molecular weight compounds with affinity for nucleic acids and for the detection of the hybridisation reaction. The first application is related to the molecular interaction between surface-linked DNA and the target pollutants or drugs, in order to develop a simple device for rapid screening of toxic or similar compounds. The determination of such compounds was measured by their effect on the oxidation signal of the guanine peak of calf thymus DNA immobilised on the electrode surface and investigated by chronopotentiometric analysis. The DNA biosensor is able to detect known intercalating compounds, such as daunomycin, polychlorinated biphenyls (PCBs), aflatoxin B1, and aromatic amines. Applicability to river and waste water samples is also demonstrated. Disposable electrochemical sensors for the detection of a specific sequence of DNA were realised by immobilising synthetic single-stranded oligonucleotides onto a graphite screen-printed electrode. The probes became hybridised with different concentrations of complementary sequences present in the sample. The hybrids formed on the electrode surface were evaluated by chronopotentiometric analysis using daunomycin as indicator of the hybridisation reaction. The hybridisation was also performed using real samples. Application to apolipoprotein E (ApoE) is described, in this case samples have to be amplified by PCR and then analysed by DNA biosensor. The extension of such procedures to samples of environmental interest or to contamination of food is discussed.
Capillary electrophoresis (CE) can be a valuable tool for on-line monitoring of bioprocesses. Production of organic acids by phosphorus-solubilizing bacteria and fermentation of UHT milk were monitored and controlled by use of a membrane-interfaced dialysis device and a home-made microsampler for a capillary electrophoresis unit. Use of this specially designed sampling device enabled rapid consecutive injections without interruption of the high voltage. No additional sample preparation was required. The time resolution of monitoring in this particular work was approximately 2 h, but could be reduced to 2 min. Analytes were detected at low µg mL–1 levels with a reproducibility of approximately 10%. To demonstrate the potential of CE in processes of biotechnological interest, results from monitoring phosphate solubilization by bacteria were submitted to qualitative and quantitative analysis. Fermentation experiments on UHT milk showed that monitoring of the processes by CE can provide good resolution of complex mixtures, although for more specific, detailed characterization the identification of individual substances is needed.
Human urine samples after fish consumption have been investigated by low-temperature gas chromatography with inductively coupled plasma mass spectrometric detection after sample derivatization by hydride generation (HG/LT-GC/ICP-MS). This analytical technique enabled the identification of organometal(loid) compounds in human urine; species of the six elements germanium, arsenic, selenium, tin, antimony, and mercury were determined. Three different organic selenium species, two germanium species, seven arsenic species, four tin species, five antimony species, and one species of mercury were found; 18 of the 22 species detected could be identified. The relative detection limits ranged between 2 and 12 pg x L(-1) (x=element). These organometal(loid) compounds probably build up in the human body under the influence of micro-organisms, in the presence of hydrogen sulfide and methane, in the human intestine.
Linear alkylbenzene sulfonates (LAS) have been determined in samples of the influent and the effluent, and in the sludge, from sewage-treatment plants (STP). LAS and sulfophenyl carboxylate compounds (SPC) were isolated by solid-phase extraction (SPE) with the polymeric phase Isolute ENV, then determined by liquid chromatography–electrospray mass spectrometry (LC–ESI–MS). The method enabled unequivocal identification of C10–C13 LAS by monitoring the ion at m/z 183 and the base peak corresponding to the [M–H]– ion. Average recoveries varied from 77–93% and the linear range of the method varied from 0.2 to 10 µg L–1, with a limit of detection ranging from 10 ng L–1 to 1.5 µg L–1 when 200 mL waste water were preconcentrated. For sewage sludge, recoveries varied from 58 to 90% and the linear range was between 0.2 and 100 µg L–1, with a detection limit ranging from 0.4 to 120 µg kg–1 when 2.5 g sewage sludge was extracted. Unequivocal identification and determination of some metabolites of the LAS, the sulfophenyl carboxylate compounds (SPC), was achieved by monitoring [M–H]– ions.
A chemical solution-deposited multilayer system of SrTiO3 ("STO")/La0.5Sr0.5CoO3 ("LSCO") on a platinized wafer with a layer sequence Pt/TiO2/SiO2/Si(bulk) has been investigated by dynamic SIMS (secondary ion mass spectroscopy) and TEM (transmission electron microscopy); element determination was performed with EELS (electron energy-loss spectroscopy). The STO layer is intended to serve as a dielectric layer for a microelectronic capacitor; the conducting LSCO layer is a buffer layer intended to eliminate fatigue effects which usually occur at the STO/Pt interface. The SIMS depth profiles obtained for the main components revealed intense diffusion processes which must have occurred during the deposition/crystallization processes. Ti is found to diffuse from the (insulating) STO layer into the conductive LSCO layer where a region of constant concentration is observable. TEM–EELS experiments showed that these Ti plateaus are caused by precipitates approximately 20–80 nm in diameter.
To investigate probable health benefits of flavonoids and stilbenes in red wine a new reversed-phase (RP) high-performance liquid-chromatographic (HPLC) method with enhanced separation efficiency and improved selectivity, sensitivity, and speed has been established for determination of the flavonoids quercetin, myricetin and kaempferol and the stilbenes cis- and trans-resveratrol, in a single run . UV-absorbance, fluorescence (FLD), and mass-spectrometric (MS) detection were also evaluated. UV-absorbance detection at 320 nm for stilbenes and 377 nm for flavonoids enables their determination up to the nanogram range with a linearity of R2>0.9999 (linear range 50 ng mL–1–50 µg mL–1). Calculated values of average recoveries were between 95 and 105% for all analytes. For resveratrol, fluorescence detection was highly selective and twice as sensitive as UV detection, and linearity was satisfactory (R2>0.9996; linear range see UV detection). For the detection of the hydrophilic glycosidic compounds piceid and rutin, which are coeluted with other hydrophilic ingredients, the validated RP HPLC system was coupled to a quadrupole ion-trap mass-spectrometer (MS) via an electrospray interface (ESI) with 25% ammonia solution as sheath liquid. MS detection was, highly linear (R2>0.9878; linear range 50 ng mL–1–50 µg mL–1) for all investigated analytes and the limits of detection were in the low nanogram range. Compared with UV detection MS detection resulted in a 200% increase in signal intensity for myricetin and 400% increases for quercetin and kaempferol, but equal signal intensity for resveratrol. Calculated values of average recoveries were 102% for myricetin and 79% for piceid. Collision induced dissociation (CID) was also used to obtain characteristic fragmentation fingerprints to facilitate qualitative and quantitative analysis even in complex matrices. Finally, this hyphenated HPLC–ESI–MS method was highly suitable and an essential improvement compared with UV- and fluorescence detection.
The analysis of seized nuclear material aims at identifying the origin of the material. Determination of the n(18O)/n(16O) ratio for the uranium oxide adds another characteristic property to the pattern which enables location of the production area of the material. A method has been developed for n(18O)/n(16O) ratio measurement which uses thermal ionization mass spectrometric (TIMS) analysis of the 238UO+ species. It has been shown that uranium oxides of different geographic origin have significantly different n(18O)/n(16O) ratios, whereas different samples of the same origin have constant oxygen isotopes ratios.
An enzymatic assay has been developed for the quantitative detection of alkyl polyglycosides after enzymatic hydrolysis with different carbohydrolases. A three-step enzymatic method was used for the quantification of alkyl polyglycosides. In the first step the enzymatic hydrolysis of alkyl polyglycosides was performed with different carbohydrolases, or an acid hydrolysis was used. The second step was quantification of free glucose with an enzyme electrode, which was covered with an immobilized glucose oxidase membrane; glucose was used as standard. The last step was the enzymatic quantification of fatty alcohols, which are the second substrate after enzymatic hydrolysis of alkyl polyglycosides. Surprisingly, the enzyme alcohol dehydrogenase ADH (E.C. 1.1.1.1) from bakers' yeast could efficiently oxidize a wide variety of aliphatic alcohols and had the highest catalytic specificity with short and medium fatty alcohol substrates, including octanol and decanol.
The sulfur compounds of refractory organic substances (ROS) of different origin have been characterized. Total organic sulfur was determined by elemental analysis. Sulfur-containing amino acids methionine and cystine were analyzed chromatographically after hydrolysis with HCl or by proteolytic digestion using enzymes. The results obtained from elemental analysis show that the total amount of sulfur is strongly dependent on the origin of the samples, because of different environmental factors during the formation of ROS. For naturally occurring samples isolated from soil seepage water, bog lake water and ground water the carbon-to-sulfur atomic ratios (C/S) decrease with the stage of humification, because of preferential loss of carbon. In humic acids (HA) isolated from secondary effluent the high value of the nitrogen-to-sulfur ratio (N/S) was indicative of a large amount of protein-derived nitrogen and sulfur compounds. In the solutions from acid hydrolysis the total amount of amino acid carbon related to the dissolved organic carbon (DOC) was generally less than 5%. Percentages of cystine related to all the amino acids detected were in the range 4 to 16%; methionine was below the detection limit for most samples. The results show that cystine is very important among the amino acids released. Enzymatic release generally resulted in smaller amounts of amino acids, indicating that these molecules are not only present in bioavailable protein-like structures. The data were compared with those from other approaches reported in the literature for the speciation of sulfur forms in ROS, including potentiometric titration, differential reduction methods, and spectroscopic investigations.
Synchronized cyclic capillary electrophoresis (SCCE) makes use of a closed loop separation channel by which the same sample can be separated during many cycles. This enables the repeated use of the same voltage for separations such that a high total voltage, and thus high efficiency, is obtained for the synchronized components. This can be accomplished by using any type of polygon geometry for the separation channel; and calculations of the available field and number of connections needed for polygons from 3 to 5 sides are presented. Triangular designs have the advantage of using the lowest number of wells. Such designs are described, with two additional features compared to that of earlier work: 1. voltage connections that are much shallower than the separation channel, to reduce losses and dispersion at the intersections; and 2. corners that are narrower than the separation channels to reduce dispersion in the turns.Experimental data is presented for the separation of a mixture of amino acids, and for a DNA separation in a polymeric sieving matrix. The DNA separation is most sensitive to the corner dispersion problem, which reduces the observed efficiency for that separation.
Conductivity detection is one of the most often employed means of detection in isotachophoresis. In microanalytical devices, thin-film platinum electrodes can be used for conductivity detection and for other electrochemical methods of detection. The design and the performance of different electrode geometries for on-column contact conductivity detection with thin-film platinum electrodes integrated on an isotachophoresis PMMA-microchip is described. Three different electrode geometries for direct conductivity detection were used for the investigation of isotachophoretic separations. The influence of the width of the electrodes and their positioning relative to the separation channel was investigated. The performance of the different detectors is compared for the analysis of organic carboxylic acid anions.
The aim of this review is to describe the state-of-the-art in the analysis of A- and B-trichothecene mycotoxins in cereals and to support knowledge and experience exchange between laboratories in the field of Fusarium mycotoxin analysis. Current screening tests and quantitative methods for the most prevalent type-A and -B trichothecenes, HT-2 and T-2-toxin, and deoxynivalenol (DON) are reviewed. This includes the extraction and clean-up procedures and chromatographic methods (TLC, HPLC, GC) applied and the immunochemical methods, especially enzyme-linked immunosorbent assay (ELISA), employed for the determination of these mycotoxins. Results from recent intercomparison studies of the determination of DON are also discussed. Experience gained during these intercomparisons clearly shows the need for further improvement in the determination of trichothecenes, to obtain more accurate and comparable results. This also indicates there is a strong need for the development of further certified reference materials (CRM) which would enable comparison of measurement results between different European laboratories for several A- and B-trichothecenes. For both A- and B-trichothecenes there is still a lack of simple and reliable screening methods enabling the rapid detection of these mycotoxins at low cost.