
Objectives To assess Intravenous Immunoglobulin (IVIG) efficacy in preventing exchange transfusion (ET) in neonates with iso-immune hemolytic disease of the newborn (HDN). Study Design A retrospective data review of 22 688 neonates admitted to the NICU of Madinah Maternity and Children’s Hospital, KSA from January 2015 to January 2025 was done. Out of them, 173 neonates ≥35 weeks with HDN at risk for ET were identified based on American Academy of Pediatrics (AAP) 2022 thresholds (74 received IVIG and 99 did not). Infants were managed according to 2004 AAP guidelines. We assessed the following outcomes: rate of ET, occurrence of rebound hyperbilirubinemia, phototherapy (PT) duration, length of hospital stay, and the need for packed red blood cells (PRBC) transfusion. The association of IVIG with outcomes was adjusted to quintiles of propensity score (PS) controlling for the likelihood of receiving IVIG. Results IVIG recipients had a greater hemolytic burden (initial hemoglobin: 14.19 vs. 16.06 g/dL, p < 0.001; reticulocyte count: 11.31% vs. 8.75%, p = 0.002; positive direct antiglobulin test: 94.6% vs. 80.8%, p = 0.008). Unadjusted analyses showed that IVIG recipients, compared to the non-IVIG group, had higher ET rates (20.27% vs. 5.05%; OR 4.78 [1.65–13.84], p = 0.002), longer PT duration, extended hospital stays, and more PRBC transfusions. However, after propensity score adjustment, no significant differences were observed for ET and PRBC transfusions. Consistent differences were retained for PT and hospital stay durations. Conclusion IVIG as an adjunct to intensive PT was not associated with a statistically significant reduction in ET rates in infants with HDN.
Background Delayed cord clamping (DCC) and umbilical cord milking (UCM) are placental transfusion techniques that improve oxygen delivery and cardiac output. UCM enhances cerebral oxygenation without delaying resuscitation. Functional closure of the ductus arteriosus (DA) usually occurs within 48 hours after birth in full-term infants, with a high incidence of persistent DA in premature infants. Objective To investigate the effects of UCM and DCC on functional ductus arteriosus closure and cerebral tissue oxygenation. Methods This randomized controlled clinical trial included 100 preterm infants who were allocated to either the UCM group ( n = 50) or the DCC group ( n = 50). crSO 2 and cfTOE were measured after resuscitation and at 12, 24, and 48 hours of life. Echocardiography was performed at 6, 12, 18, 24, and 48 hours of life to assess functional DA closure. Results Repeated-measures analysis showed no statistically significant between-group differences in changes in crSO 2 (P = 0.194), cfTOE (P = 0.140), or functional DA closure (P = 0.372). Conclusion UCM and 60-second DCC showed no statistically significant differences in cerebral tissue oxygenation improvement or functional ductus arteriosus closure during the first 48 hours of life.
Objectives To evaluate the relationship between early speckle-tracking echocardiography (STE)-derived longitudinal strain and conventional measures of ventricular systolic function in extremely preterm infants and assess their association with mortality before hospital discharge. Methods This retrospective cohort study included inborn infants born at less than 29 weeks of gestation admitted to a tertiary neonatal intensive care unit between October 2023 and December 2025. Standardised targeted neonatal echocardiography was performed within 72 hours of birth. Left ventricular (LV) and right ventricular (RV) longitudinal strain and conventional measures of ventricular function were evaluated in relation to mortality. Each measure was entered separately into multivariable models adjusted for gestational age and 5-min Apgar score, with bootstrap internal validation. Results Among 144 infants, 32 (22.2%) died before hospital discharge. Infants who died had less negative LV and RV longitudinal strain and lower conventional measures of LV and RV systolic function than survivors (all p < 0.001). LV strain correlated strongly with LV ejection fraction (r = −0.811) and fractional shortening (r = −0.868), while RV strain correlated strongly with RV fractional area change (r = −0.898) and RV output (r = −0.780) (all p < 0.001). All evaluated echocardiographic measures showed high apparent discrimination for mortality (AUC 0.910 to 0.955; all p < 0.001), without significant differences between strain and conventional measures, and remained associated with mortality after adjustment (optimism-corrected c-statistics 0.915 to 0.964). Conclusions STE-derived longitudinal strain was closely associated with conventional measures of ventricular systolic function, while both deformation-based and conventional measures were associated with mortality; these exploratory findings require external validation. STE may provide a complementary component of early neonatal haemodynamic assessment in extremely preterm infants.
Introduction Neonatal hypoxic-ischemic encephalopathy (HIE) is a major cause of neonatal morbidity and mortality. Therapeutic hypothermia (TH) is the standard neuroprotective intervention; however, it significantly influences cardiovascular function, necessitating careful hemodynamic monitoring. Aim To evaluate hemodynamic changes in term neonates with HIE during therapeutic hypothermia and the subsequent rewarming phase using serial echocardiographic assessment. Materials and methods This prospective observational study included 32 term neonates with suspected perinatal or intrapartum hypoxia admitted within 6 hours of birth. All patients underwent whole-body TH followed by controlled rewarming. Hemodynamic evaluation was performed using serial echocardiography at predefined time points during cooling and after rewarming. Cardiac troponin I levels were measured at admission, during cooling, and after rewarming, and compared with levels in healthy neonates. Results Serial echocardiography demonstrated significant changes in cardiovascular function across the cooling and rewarming phases. Cardiac output, left ventricular output, fractional shortening, right ventricular output, and tricuspid annular plane systolic excursion showed significant changes over time, with several measures of ventricular systolic function improving after rewarming. Myocardial performance indices also decreased over time, indicating changes in global ventricular performance. Superior vena cava flow and pulmonary artery pressure increased during cooling and remained elevated during the early post-rewarming period. Inferior vena cava collapsibility and right ventricular systolic/diastolic indices also showed significant changes across the study period. Cardiac troponin I levels did not differ significantly between the cooling and post-rewarming measurements (0.19 ± 0.02 vs. 0.20 ± 0.02 ng/mL, P = 0.825). Correlations between echocardiographic parameters and clinical severity markers, including pH, Apgar score, and Sarnat stage, were variable. Conclusion TH induces significant but reversible alterations in cardiac function in neonates with HIE. Serial echocardiographic assessment provides valuable insights into these dynamic changes and may support individualized cardiovascular management during both cooling and rewarming phases. Larger multicenter studies with longer follow-up are needed to determine their clinical significance and relationship with neonatal outcomes.
BackgroundNon-invasive positive pressure support (NPPS) can contribute to excessive gastrointestinal air accumulation in preterm infants, resulting in gaseous abdominal distension and gastrointestinal (GI) dysmotility. Evidence supporting interventions to manage these effects is limited. This study explored GI and safety outcomes associated with an external abdominal support intervention (ASI) in preterm infants receiving NPPS.MethodsThis retrospective, pre-post case series included 16 infants receiving ASI while on NPPS between June 2024 and February 2025. GI outcomes included daily frequency of emesis, glycerin administration, and abdominal radiographs obtained for abdominal concerns before and during ASI. Abdominal radiographs were also classified descriptively as Normal, CPAP Belly, or Other. Safety outcomes included necrotizing enterocolitis (NEC) and skin breakdown.ResultsFollowing ASI initiation, median daily emesis frequency decreased from 0.42 to 0.08 episodes/day (p = .04), glycerin administration from 0.02 to 0 administrations/day (p = .04), and abdominal radiographs obtained for abdominal concerns from 0.06 to 0 radiographs/day (p = .02). Among infants with available radiographs, a CPAP Belly pattern was present in 10/14 (71.4%) before ASI and 5/12 (41.7%) during ASI. No infants developed NEC during the intervention. One infant experienced transient skin breakdown associated with incorrect device application. The event resolved within 48 hours, and ASI was subsequently resumed.ConclusionExternal abdominal support was feasible to implement in this small cohort of preterm infants receiving NPPS. Lower frequencies of emesis, glycerin administration, and abdominal radiographs for abdominal concerns were observed during ASI use. Prospective controlled studies are needed to evaluate the safety and effectiveness of external abdominal support.