Objective To correct the counting loss of 37 Ar below the activity threshold during the measurement of the absolute activity of the inert radioactive gas 37 Ar using the proportional counter filled with gas. Methods Monte Carlo simulation with Geant4 was performed to establish a proportional counter model and output the energy deposition spectrum of 37 Ar, which were used to simulate and analyze the causes and correction of counting loss. Results The photon detection efficiency was only 38.7% at 60 kPa. The counting loss was mainly caused by the wall effect produced by the photons, which could be reduced by increasing the gas pressure and corrected by extrapolation. The influence of wall effect at 100 kPa was 4.4%, and the deviation between simulation and experiment was < 0.6%. Conclusion A factor could be calculated by Geant4 simulation for the correction of counting loss, thus achieving the accurate measurement of 37 Ar activity by proportional counter.
本论文提出了一种基于物联网技术的核辐射环境监测方案,主要采用ZigBee无线通信协议标准、专线联网拓扑结构和云端处理等技术,实现从核辐射监测现场X射线、γ射线、α射线、β射线、中子等放射性数据的采集、定位、传输、追踪、监测和管理的全过程.经初步应用,该系统具有移植性好、扩展性强、信息传输安全及数据信息深度挖掘等特点.
目的 调查青岛市介入放射诊疗资源及防护用品和个人剂量计佩戴情况,为加强介入放射学工作人员辐射防护和健康管理提供数据支持.方法 对全市范围内所有开展介入放射诊疗活动的医疗机构进行问卷调查并进行汇总分析,数据统计时间为2020年4月1日-2021年3月31日.结果 青岛市共有31家医疗机构开展了放射介入诊疗.其中三级医院23家(74.20%),二级医院8家(25.80%).全市共有介入放射诊疗设备88台,89.77%的设备位于三级医院.介入诊疗专业人员921人,其中三级医院865人(93.92%),二级医院56人(6.08%).平均每年每千人口介入诊疗人次为5.72.个人防护用品配置率最高的为铅橡胶围裙(铅衣)、铅橡胶帽子和铅橡胶颈套,配置率均为100%.介入防护手套配置率最低,仅为51.61%.辅助防护用品配置平均每台设备均不足1件.介入放射工作人员双剂量计的佩戴率84.36%.结论 青岛市开展介入放射诊疗业务的医疗机构以三级医院为主.配备的个人防护用品最多的是铅橡胶围裙、铅橡胶帽子和铅橡胶颈套,介入铅防护手套以及辅助防护设施和双剂量计的配置率偏低.
目的 计算人员受3种X射线机和2种γ放射源误照射情况下的器官剂量及其剂量转换系数,为事故剂量快速估算提供简便方法.方法 在FLUKA模拟软件中构建X射线机和2种γ放射源的辐射源模型并导入中国参考人体素模型,模拟计算人员在距源项1 m处受由前向后照射时的器官吸收剂量、器官吸收剂量与空气比释动能的剂量转换系数和器官吸收剂量与辐射源的转换系数.结果 对肺、心脏、肌肉和软组织、肝脏、皮肤和大脑的吸收剂量与空气比释动能的转换系数范围为0.30~1.19(Gy/Gy);对X射线机,这6个器官的吸收剂量与输出量的转换系数范围为6.12 × 10-3~2.90 × 10-2 Gy·m2/(mA·min);对γ放射源,6个器官吸收剂量与活度的转换系数范围为1.12 × 10-8~7.01 × 10-8 Gy·m2/(GBq·s).结论 器官吸收剂量与空气比释动能的转换系数和器官吸收剂量与探伤机输出量或活度的转换系数可为快速评估类似辐射事故提供重要的剂量学参数.
目的 保证实验室γ能谱仪对样品中放射性核素测定的准确度,提高实验室人员放射性核素分析检测能力.方法 连续参加由中国疾病预防控制中心组织的全国放射性核素γ能谱分析能力考核,利用GEM-MX7080P4型高纯锗γ能谱仪对样品进行测量,对2014-2021年的γ能谱分析能力考核结果进行分析.结果 本实验室2014-2021年γ能谱分析能力考核结果总体合格率为100%(8/8),总体优秀率为39%(3/8),涉及208Tl、228Ac、232Th、40K、238U和137Cs放射性核素28个测量结果的RD)、Z、U和Urel的分布范围分别为-1 1.82%~5.97%,-0.59~0.30,0.02~0.92和4.33%~10.49%.结论 本实验室利用γ能谱分析放射性核素方法正确,出具的检测报告准确可靠.
目的 了解石岛湾核电站运行前饮用水中总α、总β放射性水平.方法 在石岛湾核电站周围30km内设置10个采样点,2018-2021年间每年分别于枯、丰水期进行采样,依据《生活饮用水标准检验方法放射性指标》(GB/T 5750.13-2006)进行实验室检测.结果 2018-2021年间石岛湾核电站周围30 km内饮用水中的总α放射性范围约为0.004~0.420 Bq/L,未超出国家标准规定的总α指导值要求;2018-2021年总β放射性水平约为0.008~1.050 Bq/L,2018年距核电站4.7 km处的采样点中总β超过国家标准《生活饮用水卫生标准》(GB 5749-2006)指导值,扣除40K对总β放射性水平的影响,经实验室复测后在国家标准指导值以内.结论 石岛湾核电站周围30km内饮用水中排除40K对总β的影响,总α、总β放射性水平均在国家标准指导值以下.
目的 分析2018-2022年全国放射诊疗设备质量控制检测技术培训情况,总结培训效果.方法 收集整理中国疾病预防控制中心辐射防护与核安全医学所2018-2022年举办的"全国放射诊疗设备质量控制检测技术培训班"资料,分析培训执行情况.结果 2018-2022年共举办5期"全国放射诊疗设备质量控制检测技术培训班";培训天数均为4天;授课教师中具有正高级职称的比例为87.5%(35/40);共培训放射卫生专业技术人员1045人次,其中87.1%(910/1045)具有本科及以上学历,75.1%(785/1045)为中级及以下职称;培训合格率为97.7%(905/926);在培训关键环节如授课内容、教学安排等方面,学员满意度均高于96.0%.结论 全国放射诊疗设备质量控制检测技术培训工作执行情况良好,培训合格率和满意率均达到95.0%以上,培训效果良好,有助于专业人员更好地了解和掌握放射诊疗相关设备的质量控制检测技术,促进放射卫生继续医学教育高质量发展.
目的 构建快速预测系统,提高场区尺度核事故后果评价计算精度和效率.方法 开展场区尺度范围内复杂下垫面周围风场和污染物扩散的快速预测方法研究,采用风场诊断模型和拉格朗日粒子扩散方法,以显式分辨建筑物和植被分布的方式,建立场区尺度快速预测系统;通过数值模拟理想和真实城市场区算例,并与风洞实验测量数据和计算流体力学数值结果进行比较,研究复杂下垫面对局地风场和污染物输运的影响.结果 快速预测系统能在约5 min时间内清晰的模拟出局地高分辨率风场以及污染物浓度分布信息,建立与地理信息软件的接口,并可以实现与中尺度气象预报模式的耦合;从计算准确性上看,系统对风场模拟效果良好,风速和风向的分数偏差分别为0.33和-0.08,模拟的浓度场的范围受风场影响较大,除个别低浓度点外,模拟和观测的浓度比值在0.05~3.40之间.结论 快速预测系统可以在保证计算精度的基础上,有效模拟出流场分布特征,提高计算效率,为核事故应急响应提供重要参考和依据.
职业卫生管理是评价用人单位职业病防治状况的最主要指标之一,但目前国内尚缺职业卫生管理评价标准或规范.分析评价用人单位职业卫生管理存在问题,要求技术人员必须掌握国家相关法律法规标准规范,技术要求高,现实中职业卫生管理评价方式不一,内容相差大,分析不透,存在问题多,没有达到实际效果.2016年职业病防治法修订取消了建设项目职业病危害评价机构资质许可、评价技术人员个人资质许可,评价报告撰写人数量增加,水平有待提高;2018年职业卫生监督职责由安监系统划转卫生系统,职业卫生监督员水平也亟待提升.本文主要分析讨论职业卫生管理评价内容及方法、存在的问题与建议,为进一步完善职业卫生管理提供参考.
目的 初步调查银川市城乡住宅室内氡浓度水平及估算有效剂量.方法 采用固体核迹径法,选择银川市城市49户、农村18户,共计67间居室累积测量3个月以上.结果 银川市城乡室内氡浓度算术平均值为64 Bq/m3,几何均值为59 Bq/m3,中位数为57 Bq/m3,范围为25~172 Bq/m3,室内氡浓度大于100 Bq/m3的测量点占7.5%.农村室内氡浓度高于城市.室内氡浓度呈冬季最高,夏季最低的特点.室内氡所致银川市居民有效剂量为1.86mSv/a.结论 本次银川市室内氡浓度调查结果比上世纪九十年代测量结果有显著上升,年有效剂量高于世界及全国平均水平.
目的 分析2021-2022年北京市60台牙科口外X射线设备的验收检测结果,了解北京市临床新安装牙科口外X射线设备主要类型和各生产厂家安装调试整机水平,总结检测中发现的问题,提高设备检测水平.方法 按照卫生行业标准《医用X射线诊断设备质量控制检测规范》(WS 76-2020)进行现场验收检测和评价.结果 60台牙科口外X射线设备总体合格率为98.33%;同一台口外机,全景扫描与头颅摄影两种模式时,在相同管电压条件下,两种模式管电压指示的偏离最大相差5.5%,有用线束半值层最大相差1.22 mm Al,管电压指示的偏离和有用线束半值层两个指标相应的检测结果并不一致;两种模式时,曝光时间指示的偏离检测结果也存在一定的差异,最大相差75.51%.结论 加强设备出厂设备质量控制和安装调试环节,新安装设备的性能基本是有保障的.检测中,保证剂量仪探头的有效测量点位于主射线束中心轴上非常重要.
目的 为了提高参比单位环境实验室对气溶胶样品中134Cs、137Cs和60Co分析水平.方法 组织参比单位环境实验室依据GB/T 16145-1995《生物样品中放射性核素的γ能谱分析方法》国家标准开展气溶胶样品中134Cs、137Cs和60Co标准样品的比对测量,比对结果采用标准值偏差进行判定.结果 气溶胶样品中134Cs、137Cs和60Co比对参加单位6 家.134Cs:相对偏差小于 10%,占 50%;10%~20%,50%;137Cs:相对偏差小于 10%,占 33.3%;10%~20%,76.7%;60Co:相对偏差小于10%,占100%.整体比对结果可以接受.结论 参加本次比对的实验室,整体比对结果良好.
目的 了解南阳市医疗机构放射卫生管理现状,分析存在问题并提出改进措施,提高医疗机构放射诊疗工作管理水平.方法 按照河南省职业病防治项目工作方案,选取不同级别的66家从事放射诊疗工作的医疗机构进行问卷调查,并结合现场查验、询问、查阅相关资料等方法.结果 66家医疗机构持有放射诊疗许可证65家,持证率98.5%;"新建、改建、扩建"建设项目17个,评价率94.1%.本次调查放射诊疗设备共391台,开展设备状态检测387台,检测率99.0%,合格367台,合格率94.8%;稳定性检测55台,检测率14.1%;工作场所防护检测率99.0%,合格率100%;66家医疗机构有放射工作人员1809人,职业健康体检率97.8%;培训1262人,培训率95.7%;个人剂量监测1773人,监测率98.0%.结论 医疗机构应在许可变更、建设项目评价、设备稳定性监测等方面进一步加强管理,提高放射卫生管理水平.
随着核能的开发利用,核设施的安全运行已成为公众共同关注的社会问题之一,国家高度重视核应急的预案和法制、体制和机制建设.其中,核应急航空监测的应急准备与响应是国家核应急体系的重要组成部分之一,核应急航空监测技术体系中正在建设有人机和无人机航空监测优势互补的技术体系.近几年来,不同载荷、不同类型的无人机应运而生,搭载的探测器尺寸、种类也趋于多样化,无人机用于核事故应急航空监测的技术研究不断取得深入和提高,核事故应急航空监测技术体系同时得到发展.针对无人机核事故应急航空监测,本文从监测装备与技术、应急预案、应急监测与评价、监测标准、应急人员、应急保障、培训与演练几个方面的视角,对无人机核事故应急航空监测技术体系的构建进行探讨.无人机是一个正在飞速发展的航空器,随着其性能的不断改进和核应急航空监测新技术的不断革新和发展,无人机核应急航空监测技术体系将会不断得到完善和发展,逐步走向网络化、智能化、标准化.
回顾一起医疗机构为儿童受检者进行放射检查时照射野过大且未使用防护用品案件的查处过程,为今后同类案件的查处提供借鉴.通过对该案件取证方式、法律适用等方面进行分析,提出要完善放射相关法律法规标准,改进防护设施、规范执法程序、加强放射卫生宣传培训等建议,切实保障受检者的健康权益.
目的 调查四川省地表水体中Th的含量,评价居民摄入地表水体中的Th导致的健康风险.方法 在四川省主要地表水体中设置23个监测断面,于2016-2021年期间,在枯水期和平水期分别检测水体中Th的放射性水平,通过计算摄入地表水体中的放射性Th,结合健康风险评价模型对居民的健康风险进行评价.结果 四川省地表水体中Th的放射性含量为0.02~0.67 μg/L;不同年度、不同地表水体中Th的放射性水平间比较,差异均无统计学意义(P>0.05);不同水期Th的放射性水平间的差异有统计学意义(P<0.05).通过饮水、水体浸没途径摄入Th而所致各年龄组的总年均待积有效剂量范围为3.14 × 10-8~8.75 × 10-7 Sv,均低于世界卫生组织(WHO)的推荐参考水平(即0.1 mSv),对各年龄段居民所致的总致癌风险处于3.93 × 10-10~1.09 × 10-8,均低于WHO和国际放射防护委员会(ICRP)发布的最严格控制限值.结论 四川省主要地表水体中的Th经直接饮水、水体浸没途径摄入所致健康风险处于可接受水平,全省主要地表水体中的Th对各年龄组都是安全的.
目的 分析质子固定束治疗室内感生放射性剂量分布及屏蔽材料的影响.为质子治疗辐射防护及屏蔽材料选择提供依据.方法 利用FLUKA模拟质子固定束治疗室内感生放射性剂量分布、剂量随时间的变化情况及不同混凝土材料的影响.结果 质子治疗室内感生放射性剂量分布主要集中于靶周边,且冷却3~5 min后剂量迅速降为停止照射时刻的5~10倍.混凝土中感生放射性会在主射束末端靠近屏蔽体内侧形成剂量略高区域,混凝土中Fe、O、H、等元素含量对治疗室内感生放射性剂量有显著影响(P<0.01),且治疗室内感生放射性剂量与Fe元素含量呈负相关.结论 质子治疗室内治疗后的患者、空气和屏蔽材料的感生放射性均是工作人员外照射剂量的主要来源,采取时间的防护方式最为有效.在不考虑施工难度等因素,从外照射防护效果和感生放射性剂量贡献的影响上分析,在质子治疗室的屏蔽材料选择上含Fe较多的重混凝土为最优选择.
目的 为了解重庆市食品中放射性核素含量水平,开展重庆市食品放射性调查.方法 采集重庆市蔬菜、粮食、奶粉和茶叶共计114份,干燥,粉碎,制成粉末,装入马林杯,用GEM40P4-765高纯锗γ谱仪进行核素测量.结果 重庆市食品中天然放射性核素238U、232Th、226Ra、40K活度浓度平均值为(0.396±0.510)、(0.199±0.296)、(0.140± 0.209)、(119.250±105.470)Bq/kg,不同食物中放射性核素含量差异有统计学意义(P<0.05).人工放射性核素137Cs活度浓度平均值为(0.091±0.308)Bq/kg,对9份茶叶进行了90Sr测量,活度浓度平均值为(1.243±0.860)Bq/kg.结论 重庆市食品中放射性核素含量水平低于国家标准限值,但食品放射性安全仍需重视,需进一步长期进行放射性食品监测.
目的 探究小檗碱(BBR)对电离辐射损伤大鼠的保护作用及机制.方法 把SD大鼠分为7组:正常对照组、1 Gy组、1 Gy低、高剂量BBR组(50,150 mg/kg)、3 Gy组、3 Gy低、高剂量BBR组(50,150 mg/kg).除正常对照组外,各组大鼠进行医用电子直线加速器外照射,照后BBR灌胃给药,连续10 d.微量法测定大鼠血清超氧化物歧化酶(SOD)、还原型谷胱甘肽(GSH)和丙二醛(MDA)水平,HE染色法观察骨髓、小肠病理变化.结果 与正常对照组比较,辐射组大鼠血清MDA明显升高(P<0.05),SOD、GSH明显降低(P<0.05),骨髓、小肠病理损伤加重.与辐射组比较,BBR组大鼠MDA血清水平明显下降(P<0.05),SOD、GSH明显升高(P<0.05),骨髓、小肠病理损伤减轻,高剂量组更为明显.结论 小檗碱对辐射损伤大鼠具有一定的保护作用,机制可能是提高抗氧化物质的活性,增强对自由基的清除能力,从而减轻自由基造成的氧化损伤.
目的 评估钚气溶胶α反冲导致的迁移能力.方法 本文用蒙特卡罗方法对含钚纳米气溶胶的反冲沉降和布朗运动进行了模拟.首先抽样了反冲角度和沉降过程中的布朗运动纵向落地首达时,然后抽样出横向布朗运动位移来确定气溶胶最终沉降位置.结果 对于粒径10-50 nm的气溶胶单次反冲沉降作用最大的迁移距离为1.39μm,布朗运动会使其迁移能力增大,大概率沉降至100μm以内,仍有小概率长时间滞空悬浮.结论 α反冲是钚气溶胶迁移的机制之一.纳米气溶胶长距离迁移的重要机制是反冲后的布朗运动可能使其长时间悬浮.