This work throws light on the reflection and transmission phenomenon due to incident plane longitudinal wave at a plane interface between inviscid fluid half-space and a nonlocal bio-thennoelastic diffusive half-space. The governing equations are formulated by adopting nonlocal heat conduction and mass diffusion along with dual phase lag (DPL) model. The amplitude ratios are obtained analytically and these amplitude ratios are used to drive energy ratios. The distribution of energy of incident wave among reflected and transmitted waves are obtained. The obtained ratios are impacted by angle of incidence, frequency and different properties of media involved. Numerically examined energy ratios are displayed in the form of graphs to know the effect of nonlocal parameters, lagging times, stiffness and blood perfusion rate.
This study contains a comparative analysis of two polymers: PEEK and UHMWPE. A stress distribution pattern in a knee joint endoprosthesis insert was determined for both materials. A numerical model of the insert generated by means of the SOLIDWORKS software was used in calculations. For the purpose of the calculations it was assumed that the insert is loaded consistently and symmetrically, and the value of the load applied was determined for a person of a total weight of 120 kg.
Femoral stems with proximal metaphyseal involvement are commonly used total hip replacement components with very good results. In this study, total hip arthroplasty (THA) application was analyzed using a three-dimensionally modeled human hip joint by finiite element method. The aim of the study is to investigate the effects of changes in the direction of the femoral stem on these complications. Finite element analysis is performed on a model of femur bone by varying the femur angles. Finite element models were prepared for three different positions (5 degrees varus, neutral, 5 degrees valgus) on the femur without cement during walking motions. A sinusoid dynamic load with amplitude between 300 N and 1700 N and with a frequency of 1 Hz was applied. The stresses, strains and deformations that occurred on the femur and stems were determined at the end of the finite element analysis and compared to each other. Considering the results of strain, strain and deformation in the study, it is seen that the closest results to the natural load bearing of the femur are in the valgus position. The results obtained in the neutral position are also close to these results. In the metaphyseal points involving the femur stem, the highest values were found in the varus position. In all three positions, the femoral stem provides the transfer of the load from the proximal femur. The lowest stress, strain and deformation results were obtained in the valgus position, especially in the metaphyseal where the prosthesis is involved. It is seen that there are values close to this in the neutral position. This situation may be thought to result in a decrease in the proximal stress shield, an increase in bone protection compared to the varus position, a long-term loosening and a decrease in periprosthetic fracture.
Total hip prosthesis is used for the patients who have hip fracture and are unable to recover naturally. To de-sign highly durable prostheses one has to take into account the natural processes occurring in the bone. Finite element analysis is a computer based numerical analysis method which can be used to calculate the response of a model to a set of well-defined boundary conditions. In this paper, the static load analysis is based, by se-lecting the peak load during the stumbling activity. Two different implant materials have been selected to study appropriate material. The results showed the difference of maximum von Misses stress and detected the fracture of the femur shaft for different model (Chamley and Osteal) implant with the extended finite element method (XFEM), and after the results of the numerical simulation of XFEM for different was used in deter-mining the stress intensity factors (SIF) to identify the crack behavior implant materials for different crack length. It has been shown that the maximum stress intensity factors were observed in the model of Chamley.
This paper investigated vibrational behavior of the osteon as bone unit in the different situations. This study can lead to increase our knowledge of our body. In this paper free vibration of the osteon with considering it as composite material has been studied. The effect of numbers of lamellae and radius of those on natural frequency of osteon are subtle; while thickness of lamellae have decreasing trend on natural frequency of osteon. The presence of nerve and blood in haversian canal change trend of natural frequency, absolutely. Using the nonlocal strain gradient theory (NSGT) leads to effectiveness of scale parameter on equations of motion and the obtained results. The governing equations are derived by Hamilton's principles. A parametric study is presented to examine the effect of various parameters on vibrational behaviour of osteon. The results can also be regarded as a benchmark in vibration analysis behavior of osteon as bone unite.
In this study, the mathematical model that describes blood cell development in the bone marrow (i.e., hematopoiesis) has been studied via the Homotopy Perturbation Method (HPM). The results from the present work compared very well with the numerical solutions from published literature. This work has shown that the HPM is viable for solving delay differential equations born from hematopoiesis problem. The influence of the proliferating cells loss rate, time delay rate and the phase re-entry rate on the population densities of both the proliferating and resting cells were also determined through the underlined procedure.
As conventional drug delivery system is being improved rapidly by target-based drug delivery system, finding suitable Drug Delivery System (DDS) for new drugs remains a challenge. Although there are many drug delivery vehicles in existence, a significant improvement is required to some DDS such as for local, implant-based treatments used for musculoskeletal infections. Many polymers have been considered for providing the improvement in DDS. Synthetic polymer, for example, has gained popularity for broad-spectrum physicochemical and mechanical properties. This article reviews the biomedical applications of poly(TriMethylene Carbonate-co-Caprolactone) (PTMCC), which has attracted attention due to its biocompatibility, biodegradability and rubber-like properties. Its synthesis, physical properties, and degradation are also discussed here. Although it is relatively new in biomedical applications, it is readily usable for the fabrication of differing format of DDS of superior mechanical strength and degradation properties. The use of PTMCC is expected to increase in coming years as more is revealed about its potentials.
We cany the knowledge that the skeleton bones of the human body are not always without defects and some various defects could occur in them. In the present paper, as the first endeavor, flee vibration and buckling analysis of femur bones with femoral defects are investigated. A major strength of this study is the modeling of defects in femur bones. Materialise Mimics software is adopted to model the bone geometry and the SOLIDWORKS software is used to generate the defects in bones. Next, the ABAQUS software is employed to study the behaviors of bones with defects.
Development of lightweight implant plates are important to reduce the stress shielding effect for a prosthesis of femur bone fractures. Stainless steel (SS-316L) is a widely used material for making implants. Stress shielding effect and other issues arise due to the difference in mechanical properties of stainless steel when compared with bone. To overcome these issues, composite materials seem to be a better alternative solution. The comparison is made between two biocompatible composite materials, namely Ti-hydroxyapatite and Ti-polypropylene.
Eggshell is a waste material after the usage of egg. In this work, biowaste chicken eggshells were used for preparing carbonated hydroxyapatite (HA) nanoparticles of high purity through aqueous precipitation method at room temperature. The eggshell-derived HA will be a cost-effective bioceramics for biomedical applications and an effective material-recycling technology. Additionally, mulberry leaf extract was used as a template to regulate the morphology, size and crystallinity of HA, and the effects of pH value were also examined. Characterization of the samples was performed by X-ray diffraction (XRD) and Fourier transform infrared (FT-IR) spectroscopy. Scanning electron microscopy (SEM) was used to determine the size, shape and morphology of HA. The results indicate that only one phase of HA were synthesized in the both absence and presence of mulberry leaf extract at pH of 7 and above, while DCPD or DCPA/DCPD phase was observed at pH 4 condition. The crystallite sizes of the HA samples obviously decreased when adding mulberry leaf extract as a template, while they decreased gradually as the solution pH levels increased. With increasing pH level from 7 to 14, the rod-like HA nanoparticles gradually changed to spherical shape at pH 14. Note that, the obtained product is Mg and Sr containing A- and B-type carbonate HA at alkaline pH and it can be a potential material for biomedical applications.
In the present article, the general wave propagation behavior of a single lamellae biological system was analyzed. The Lamellae is the main component of cortical bone. Its shape can be approximated by a cylindrical shell; so with using shell theories as displacement relations and the nonlocal strain gradient them , (NSGT) as constitutive relation was obtained the equation of motion. Using the NSGT leads to the effectiveness of scale parameter on equations of motion and the obtained results. The governing equations are derived by Hamilton's principles. The results are showing the variations of the overall trend of wave velocity toward wave vector have descending scheme and wave frequency against wave vector have ascending scheme; also were investigated effects of size and geometrical parameters on wave velocity and wave frequency. It was shown uptrend of types of wave velocities for wave vectors greater than 10(5).
The aim of this study was to investigate the effect of total polymer concentration on the chemical structure, morphology of pores, porosity, swelling ratio, degradation of gelatin-poly (vinyl alcohol) (Gel-PVA) cryogel scaffolds. Porous cryogels were prepared with cryogelation technique by using glutaraldehyde as a crosslinker. Functional group composition of cryogels after crosslinking was investigated by Fourier Transform Infrared (FTIR). The morphology of cryogels was characterized via scanning electron microscopy (SEM) and porosity analysis. All of the cryogels had a porous structure with an average pore size between 45.58 +/- 14.28 and 50.14 +/- 4.26 mu m. The cryogels were biodegradable and started to degrade in 14 days. As the polymer concentration increased the swelling ratio, the porosity and the degradation rate decreased. Spongy and mechanically stable Gel-PVA cryogels, with tunable properties, can be potential candidates as scaffolds for tissue engineering applications.
Living beings are formed of advanced biological and mechanical systems which exist for millions of years. It is known that various animals and insects right from small ants to huge whales have different weight carrying capacities, which is generally expressed as a ratio of their own bodyweights i.e., Strength to Bodyweight Ratio (SBR). The puzzle is that when a rhinoceros beetle (scientific name: Dynastinae) can carry 850 times its own bodyweight, why a man cannot accomplish the same feat. There are intrinsic biological and mechanical reasons related to their capacities, as per biomechanics. Yet, there are underlining principles of engineering and structural mechanics which tend to solve this puzzle. The paper attempts to give a plausible answer for this puzzle through structural mechanics and experimental modeling techniques. It is based on the fact that smaller an animal or creature, it has larger value of weight lifting by self-weight ratio. The simple example of steel prism model discussed in this paper, show that smaller the physical model size, larger is its SBR value. To normalize this, the basic length of the model need to be considered and when multiplied with SBR, a constant is arrived. Hence, the aim of the research presented is to derive this constant on a pan-living being spectrum through size/scaling effect.
This paper presents a novel structural composition for artificial bone scaffolds with an appropriate biocompatibility and biodegradability capability. To achieve this aim, carbon nanotubes, due to their prominent mechanical properties, high biocompatibility with the body and its structural similarities with the natural bone structure are selected in component of the artificial bone structure. Also, according to the piezoelectric properties of natural bone tissue, the barium titanate, which is one of the biocompatible material with body and has piezoelectric property, is used to create self-healing ability. Furthermore, due to the fact that, most of the bone tissue is consists of hydroxyapatite, this material is also added to the artificial bone structure. Finally, polycaprolactone is used in synthetic bone composition as a proper substrate for bone growth and repair. To demonstrate, performance of the presented composition, the mechanical behaviour of the bone scaffold is simulated using ANSYS Workbench software and three dimensional finite element modelling. The obtained results are compared with mechanical behaviour of the natural bone and the previous bone scaffold compositions. The results indicated that, the modulus of elasticity, strength and toughness of the proposed composition of bone scaffold is very close to the natural bone behaviour with respect to the previous bone scaffold compositions and this composition can be employed as an appropriate replacement for bone implants.
Results from multiple high profile experiments on the parameters influencing the impacts that cause skull fractures to the frontal, temporal, and parietal bones were gathered and analyzed. The location of the impact as a binary function of frontal or lateral strike, the velocity, the striking area of the impactor, and the force needed to cause skull fracture in each experiment were subjected to statistical analysis using the JMP statistical software pack. A novel neural network model predicting skull fracture threshold was developed with a high statistical correlation ($R^2=0.978$) and presented in this text. Despite variation within individual studies, the equation herein proposes a 3 kN greater resistance to fracture for the frontal bone when compared to the temporoparietal bones. Additionally, impacts with low velocities (<4.1 m/s) were more prone to cause fracture in the lateral regions of the skull when compared to similar velocity frontal impacts. Conversely, higher velocity impacts (>4.1 m/s) showed a greater frontal sensitivity.
To maintain activity in a coenzyme/enzyme mixture system, such as beta-nicotinamide adenine dinucleotide (NADH)/dehydrogenase, the water-soluble 2-methacryloyloxyethyl phosphorylcholine (MPC) polymers as an additive were synthesized and investigated for their stabilizing function. The inhibitor for the NADH/dehydrogenase reaction was spontaneously formed when the NADH was stored in the dehydrogenase solution. Therefore, we hypothesized that if the additive polymer could interact with an inhibitor without any adverse effect on the dehydrogenase, the activity in the NADH/dehydrogenase mixture could be maintained. We selected lactose dehydrogenase (LDH) as the enzyme, and the NADH was dissolved and incubated at 37 degrees C in the LDH solution containing the polymers. The phospholipid polymers used in this study were poly(MPC) (PMPC), poly(MPC-co-3-trimethylammonium-2-hydroxypropyl methacrylate chloride) (PMQ) and poly(MPC-co-potassium 3-methacryloyloxypropyl sulfonate (MSO3)] (PMMSO3). The poly(MSO3) was used as a reference. For the PMQ and PMSO3 aqueous solutions, the activity of the NADH/LDH mixture system decreased with incubation time as the same level or lower than that in the Tris buffered solution in the absence of the polymers. However, for the poly(MPC-co-MSO3) (PMMSO3) aqueous solution, the activity of the NADH/LDH mixed system was six times higher than that in the buffered solution even after a 3-days incubation. The LDH activity was 1.5-1.8 times higher in the presence of the PMMSO3 compared with that in the PMSO3 solution. The mixture of two polymers, poly(MPC) and poly(MSO3), did not produce any stabilization. Thus, both the MPC and MSO3 units in the polymer chain had important and cooperative effects for stabilizing the NADH/LDH mixture.
The finite element method is wide used in simulation in the biomechanical structures, but a lack of studies concerning finite element mesh quality in biomechanics is a reality. The present study intends to analyze the importance of the mesh quality in the finite element model results from humeral structure. A sensitivity analysis of finite element models (FEM) is presented for the humeral bone and cartilage structures. The geometry of bone and cartilage was acquired from CT scan and geometry reconstructed. The study includes 54 models from same bone geometry, with different mesh densities, constructed with tetrahedral linear elements. A finite element simulation representing the glenohumeral-joint reaction force applied on the humerus during 90 degrees abduction, with external load as the critical condition. Results from the finite element models suggest a mesh with 1.5 mm, 0.8 mm and 0.6 mm as suitable mesh sizes for cortical bone, trabecular bone and humeral cartilage, respectively. Relatively to the higher minimum principal strains are located at the proximal humerus diaphysis, and its highest value is found at the trabecular bone neck. The present study indicates the minimum mesh size in the finite element analyses in humeral structure. The cortical and trabecular bone, as well as cartilage, may not be correctly represented by meshes of the same size. The strain results presented the critical regions during the 90 degrees abduction.
This article reports the development of biodegradable photoluminescent polymer (BPLP)-based nanoparticles (NPs) incorporating either magnetic nanoparticles (BPLP-MNPs) or gadopentate dimeglumine (BPLP-Gd NPs), for cancer diagnosis and treatment. The aim of the study is to compare these nanoparticles in terms of their surface properties, fluorescence intensities, MR imaging capabilities, and in vitro characteristics to choose the most promising dual-imaging nanoprobe. Results indicate that BPLP-MNPs and BPLP-Gd NPs had a size of 195 +/- 43 nm and 161 +/- 55 nm, respectively and showed good stability in DI water and 10% serum for 5 days. BPLP-Gd NPs showed similar fluorescence as the original BPLP materials under UV light, whereas BPLP-MNPs showed comparatively less fluorescence. VSM and MRI confirmed that the NPs retained their magnetic properties following encapsulation within BPLP. Further, in vitro studies using HPV-7 immortalized prostate epithelial cells and human dermal fibroblasts (HDFs) showed > 70% cell viability up to 100 mu g/ml NP concentration. Dose-dependent uptake of both types of NPs by PC3 and LNCaP prostate cancer cells was also observed. Thus, our results indicate that BPLP-Gd NPs would be more appropriate for use as a dual-imaging probe as the contrast agent does not mask the fluorescence of the polymer. Future studies would involve in vivo imaging following administration of BPLP-Gd NPs for biomedical applications including cancer detection.
Stability and loosening of implanted femoral stems in Total Hip Replacement have been well established as barriers to the primary concerns of osseointegration and long term implant survival. In-vitro experiments and finite element modeling have for years been used as a primary tool to assess the bone stem interface with variable methodologies leading to a wide range of micromotion, interference fit and stress shielding values in the literature. The current study aims to provide a comprehensive review of currently utilized methodologies for in-vitro mechanical testing as well as finite element modeling of both micromotion and interference of implanted femoral stems. A total of 12 studies detailed in 33 articles were selected for inclusion. Experimental values of micromotion ranged from 12 to 182 mu m while finite element analysis reported a wider range from 2.74 to 1,277 mu m. Only two studies were found that modeled bone/implant contact with consideration for interference fit. In studies evaluating stem micromotion in THA, the reference surface at the bone/stem interface should be well defined. Additionally, the amount of penetration considered should be disclosed and associated with bone density and roughness.
Well-ordered porous materials are very promising in orthopedics since they allow tailoring the mechanical properties. Finite element (FE) analysis is commonly used to evaluate the mechanical behavior of well-ordered porous materials. However, FE results generally differ importantly from experimental data. In the present article, three types of manufacturing irregularities were characterized on an additive manufactured porous titanium sample having a simple cubic unit-cell: strut diameter variation, strut inclination and fractured struts. These were included in a beam FE model. Results were compared with experimental data in terms of the apparent elastic modulus (Eap) and apparent yield strength (SY,ap). The combination of manufacturing irregularities that yielded the closest results to experimental data was determined. The idealized FE model resulted in an Eap one order of magnitude larger than experimental data and a SY,ap almost twice the experimental values. The strut inclination and fractured struts showed the strongest effects on Eap and SY,ap, respectively. Combining the three manufacturing irregularities produced the closest results to experimental data. The model also performed well when applied to samples having different structural dimensions. We recommend including the three proposed manufacturing irregularities in the FE models to predict the mechanical behavior of such porous structures.