• 学术搜索
  • 科研智能体
    • Research Labs
    • AI 阅读
    • AI 文库
    • 深度研究
    • 学者亮点
  • 学术资源
    • AI2000
    • 期刊/会议
    • 学者库
    • 学术API
      MCP&Skill
    • 溯源树
    • 数据集
  • 知识沉淀
    • 学术空间
订阅小程序
旧版功能
aminer vip
开通会员低至0.73元/天
一次搞定AI科研
立即登录
  • English
  • 联系方式
    npj Biosensing

    npj Biosensing

    JournalISSN 3004-8656eISSN 3004-8656

    年发文量

    研究主题

    论文(118)

    排序
    1Sensor-skin Contact Pressure As a Hidden Confounder in Wearable Photoplethysmography Biosensing
    Mohamed Elgendi, Azza Elkhalifa, Anood Alali, Sara Alameri, Shahad Alzaabi, Najoud Alhammadi,John Allen,Richard Ribon Fletcher

    Photoplethysmography (PPG) is increasingly used for cuffless blood pressure (BP) monitoring and wearable cardiovascular sensing. However, the reliability of PPG-derived digital biomarkers is highly sensitive to sensor–skin contact pressure, which influences optical coupling, vascular compression, and motion susceptibility. Despite its importance, contact pressure is often poorly controlled or insufficiently reported, introducing a hidden source of variability that can compromise signal integrity, downstream model performance, and the reproducibility of wearable BP systems. Here, we systematically review experimental evidence on the influence of contact pressure in PPG-based cuffless BP estimation. Across 29 studies of PPG acquisition, BP estimation, and related pulse sensing, those that examined contact loading reported the following qualitative patterns: insufficient pressure reduced optical stability and increased motion artefacts, whereas excessive pressure compressed superficial vasculature, attenuated systolic peaks, and suppressed the dicrotic notch. Within studies that varied contact loading, favourable conditions depended on the anatomical site, sensor, and outcome; better waveform quality did not by itself establish lower BP-estimation error or a universal pressure target. Low, moderate, and high loading conditions are therefore used only as study-defined descriptions of signal-level effects. Because reported performance metrics represented different statistical constructs, outcomes were summarized separately for signal quality, waveform morphology, timing features, and BP-estimation error; the evidence does not support quantitative ranking of classical signal-processing, statistical, and machine-learning approaches. We further identify substantial methodological inconsistency in pressure measurement, control, and reporting, and propose standardized pressure-aware practices to improve reproducibility, benchmarking, device design, and the clinical translation of cuffless BP monitoring.

    2026
    引用
    AI阅读
    加入学术空间
    2Localized Ph Modulation by Palladium Electrochemistry for Reagent-Free Regeneration of Biosensing Systems
    Christopher T. Sharkey, I. Mohamed Irfan, Martin Rubio, Bill W. Rierson, Rajendra P. Shukla, Jack S. Twiddy,Stefano Menegatti,Michael A. Daniele

    Localized electrochemical control of pH could enable reagent-free regeneration, conditioning, and actuation of biosensing systems, but practical design rules for integrating solid-state pH modulators with biointerfaces remain poorly defined. Here, we systematically characterized electrochemical pH modulation by palladium electrodes in an integrated microfluidic platform, examining how electrode morphology, applied potential, buffering capacity, and diffusion restrictions govern the rate, magnitude, and spatial propagation of pH changes. In 0.1× PBS, local pH was modulated from 7.4 to 4.6 under anodic bias and 11.6 under cathodic bias within 20–30 min (at a distance of 1 mm from the palladium electrode), while in 1× PBS the same biases produced attenuated but still substantial shifts from 7.4 to 4.6 and 10.8 over 60 min. Increasing the Pd electrode’s electrochemical surface area primarily accelerated pH modulation, while buffer strength and restricted transport suppressed both its magnitude and spatial propagation. We then evaluated the ability of palladium-driven pH modulation to perturb the response of electrochemical aptamer biosensors and regenerate peptide-mediated affinity capture. Cathodic operation, i.e., alkalinization, qualitatively reproduced the expected pH-dependent behavior of methylene blue-labeled aptamer electrodes, but anodic operation, i.e., acidification, caused rapid signal degradation, including elevated background current and loss of a resolvable redox peak over time. In contrast, palladium-driven acidification proved sufficient to trigger release of IgG2 from immobilized peptide receptors over three binding-regeneration cycles. These results establish palladium electrochemical pH modulation as a practical strategy for localized control of pH-sensitive biorecognition, while identifying important constraints for operation near redox-active electrochemical biosensors.

    2026
    引用
    AI阅读
    加入学术空间
    3A Lipoprotein-Specific Aptamer Biosensor for the Detection of Mycoplasma-Contamination in T Cell Culture
    Michael Shola David,Jann Harberts,Raquel Sánchez-Salcedo,Victor J. Cadarso,Muamer Dervisevic,Nicolas H. Voelcker

    Mycoplasma contamination remains a leading cause of insidious cell culture failure, altering cellular physiology while evading standard antibiotic treatments due to the lack of a cell wall. Current electrochemical detection strategies rely mainly on DNA-based assays that require cell lysis and DNA extraction, thereby increasing assay complexity and time. Here we report an electrochemical aptamer biosensor for the direct detection of Mycoplasma hyorhinis (MHO) through specific recognition of its high-affinity transport protein (p37). This strategy enables label-free detection of Mycoplasma and secreted p37 protein with minimal sample processing. The biosensor detected MHO in buffer and in a co-culture medium with human T cells, with a detection limit of ~2 cells/mL, a quantification limit of ~7 cells/mL, and a sensitivity of 16.9 ± 0.7%∆Rct/cells/mL. Additionally, the biosensor response in MHO sample supernatants was investigated to assess its sensitivity to the MHO lipoproteins (p37) released into the extracellular medium during growth and lysis. The results confirmed that the biosensor response originates from the released p37 protein even in the absence of MHO cells, with a consistently lower response compared to samples containing MHO cells. This study lays the foundation for a non-invasive, electrochemical Mycoplasma monitoring tool to track contamination in human T-cell cultures, supporting quality control in high-value cell therapy manufacturing workflows.

    2026
    引用
    AI阅读
    加入学术空间
    4Limited Utility of Consumer Wearable APIs for Predicting Substance Use and Craving, Despite Model Personalization
    Ali Kargarandehkordi, Agnik Banerjee, Yinan Sun, Christopher R. Slade, Yang Qian, Aditi Jaiswal, Tanvir Islam, Hiwot Belay Tadesse, Alexander Kostrinsky-Thomas, Chanhyun Park,Nhung Nguyen, Xuhai “Orson” Xu,

    We explored the feasibility of predicting, using individually-tailored artificial intelligence (AI) models, substance use and craving from Fitbit data collected in free-living conditions. Most substances examined acutely raise heart rate, and craving is known to often involve autonomic arousal. Because heart rate responds to stress, exertion, and substance use differently between individuals, we sought to study in an exploratory experiment whether individualized artificial intelligence (AI) models could learn person-specific patterns that distinguish substance-related heart rate changes from other arousal when conditioned on current activity level. We also examined whether per-participant data coverage and participant adherence to the data collection protocol could explain gaps in performance. Sixteen participants contributed 47 participant–substance–task prediction scenarios (25 substance use, 22 craving) spanning six substances. For each scenario, we trained a model to predict ecological momentary assessment responses, comparing global supervised, global self-supervised, and personalized self-supervised modeling approaches. Discrimination was modest (mean AUROC 0.569–0.617) for all substances and for both craving and use prediction, and differences in data coverage and participant adherence did not explain performance gaps. These findings suggest that heart rate and step count from a consumer wristband carry limited substance-specific signal in isolation, and thus digital intervention research may gain more traction from targeting better-characterized antecedents such as stress than from predicting use or craving directly.

    2026
    引用
    AI阅读
    加入学术空间
    5Biofluid-compatible Assay for Cytokine Tracking (BIOACT) Towards Point-of-care Diagnostics
    Sasya Madhurantakam, Georgeena Mathew, Bianca Elizabeth David, Aditya Mittal Desai, Jayanth Babu Karnam, Vikram Narayana Dhamu,Sriram Muthukumar,Shalini Prasad

    Point-of-care diagnostics are essential for managing diseases and disorders in resource-limited settings; however, their translation is limited by analytical performance in complex biofluids, particularly whole blood. Electrochemical immunosensors offer a solution for affordable, portable, quantitative PoC testing. Yet their accuracy is compromised by matrix-dependent distortions arising from viscosity, cellular interference, and endogenous electroactive species. Immunoprofiling of cytokine signatures is crucial for distinguishing latent and active tuberculosis (TB), particularly in high-burden, decentralized settings. We present BIOACT (Biofluid-Compatible Assay for Cytokine Tracking), an electrochemical biosensor platform engineered to concurrently quantify IL-10 and TNF-α, two immunologically antagonistic cytokines implicated in TB progression. This platform enables multiplex cytokine detection in whole blood (WB) and plasma, utilizing a calibration model applicable to both fluids, while demonstrating sensitivity across a detection range, with recovery rates conforming to CLSI standards. By providing robust, reproducible cytokine detection across relevant biofluids, BIOACT offers a scalable solution for point-of-care applications. With potential for multiplexed cytokine panels and integration with portable electronics, BIOACT is a point-of-care tool in resource-limited settings. It achieves plasma-level accuracy in whole blood, facilitating testing in resource-constrained environments. Results establish a framework for compensating matrix effects in biosensing and enabling multiplexed PoC platforms across settings.

    2026
    引用
    AI阅读
    加入学术空间
    立即登录,查看全部 118 篇论文

    高被引作者

    作者引用发文
    Sang-Hyun Oh145
    Mohamed Elgendi148
    Peter A. Larsen133
    Peter R. Christenson133
    Gage Rowden132
    Nathan Lindquist101
    Tsu-Te Judith Su102
    Dong Jun Lee101
    Geidy Serrano82
    Carlo Menon82

    高产作者

    作者引用发文
    Mohamed Elgendi148
    Sang-Hyun Oh145
    Reuven Gordon55
    Carlo Menon54
    Peter Zijlstra03
    Peter R. Christenson133
    Peter A. Larsen133
    Hirotsugu Ogi33
    Shalini Prasad02
    Arif E. Cetin12

    相关期刊

    暂无数据
    暂无数据