• 学术搜索
  • 科研智能体
    • Research Labs
    • AI 阅读
    • AI 文库
    • 深度研究
    • 学者亮点
  • 学术资源
    • AI2000
    • 期刊/会议
    • 学者库
    • 学术API
      MCP&Skill
    • 溯源树
    • 数据集
  • 知识沉淀
    • 学术空间
订阅小程序
旧版功能
aminer vip
开通会员低至0.73元/天
一次搞定AI科研
立即登录
  • English
  • 联系方式
    Indoor Environments

    Indoor Environments

    JournalISSN 2950-3620eISSN 2950-3620

    年发文量

    研究主题

    论文(194)

    排序
    1Characterization of the Impact of Gas Cooking on Indoor Air Quality in Households Across 7 European Countries
    Juana Maria Delgado-Saborit, Davide Moretti,Piet Jacobs

    Cooking with gas appliances increases NO2 levels indoors, contributing to higher risks of respiratory diseases. Additionally, ventilation, geolocation, building characteristics and sociodemographic factors of household dwellers might affect indoor air quality. However, little information is available on how these factors might affect indoor exposures and exceedances of recommended air quality guidelines and regulations in Europe according to cooking fuel. A large-scale study was carried out in 276 dwellings across 7 European countries measuring concentrations of NO2, PM2.5 and CO in the kitchen with active sensors for 2 weeks according to cooking appliance. NO2 concentrations were measured also with passive samplers in the kitchen, living room, bedroom, and outdoors at the façade of the building. Indoor to outdoor ratios were calculated. Participant information related to demographics, cooking factors, geolocation of the dwelling, building characteristics and ventilation patterns was gathered through questionnaires. NO2 concentrations indoors were higher (p-value<0.001) in gas cooking households (kitchen: 26.6 ± 13.8 µg/m3; bedroom: 17.6 ± 9.5 µg/m3; individual concentrations range: 3.5–75.8 µg/m3) than in those using electric cookers (kitchen: 13.8 ± 7.5 µg/m3; bedroom: 12.6 ± 6.5 µg/m3; concentrations range: 2.7–43.3 µg/m3). Kitchen and living room concentrations on gas appliances households were higher (p-value<0.001) than outdoor concentrations (17.9 ± 10.3 µg/m3; concentrations range 3.3–88.2 µg/m3). No differences (p-value>0.05) were observed in concentrations measured in the kitchen according to overall fuel type for PM2.5 (kitchen: 21.0 ± 20.7 µg/m3; concentrations range: 3.3–134 µg/m3) and CO (kitchen: 0.7 ± 0.8 mg/m3; concentrations range: 0.1–6.2 mg/m3). NO2 concentrations in households with gas cookers recorded a higher number of exceedances of the 24-h and 1-h WHO guidelines compared to homes using electric cookers (p-value<0.001). The main factors increasing indoor NO2 concentrations were cooking with a gas cooker, cooking more frequently and for longer durations. Geolocation factors related to traffic also increased indoor concentrations, independently of the type of cooking appliance. Effective ventilation of gas cooking NO2 emissions showed several challenges linked with the insufficient use of exhaust hoods and ingress of NO2 concentrations from outdoor sources via natural and/or mechanical ventilation. The findings of this study offer opportunities to reduce exposure to harmful pollutants and protect the health of the population.

    2026
    引用
    AI阅读
    加入学术空间
    2CO2 As a Proxy for PM and VOCs in Classrooms Across Ventilation Types and Activities
    Bowen Du,Joan F. Rey,Matias Cesari,Joëlle Goyette Pernot,Dusan Licina

    Poor indoor air quality in schools has been linked to adverse health outcomes and impaired cognitive performance in children. Carbon dioxide (CO2) has been widely used as a surrogate indicator of classroom air quality. This study assessed whether indoor CO2 can serve as a proxy for particulate matter (PM)- and volatile organic compound (VOC)-related air quality in classrooms, while accounting for ventilation type and classroom activities. Real-time measurements of CO2, PM1, PM2.5, PM10, and total VOCs (TVOCs), together with time-integrated measurements of individual VOCs, were collected during four week-long campaigns across 24 primary schools in Switzerland. Associations were assessed using linear regression and Spearman rank correlation, and activity effects using Kruskal-Wallis tests. Real-time CO2 showed weak pooled associations with PM and TVOCs across ventilation types. However, classroom-level associations strengthened in winter 2023 under reduced ventilation, with median Spearman coefficients reaching approximately 0.45 for both CO2–PM2.5 and CO2–TVOC across both ventilation types. Weekly mean CO2 showed modest correlations with TVOCs and moderate correlations with individual VOCs—strongest for acetaldehyde, followed by acetone, formaldehyde, ethanol, and toluene—although linear associations were weak. CO2-derived air change rates were more strongly associated with PM than CO2 concentration metrics. CO2 concentrations also varied significantly across classroom activities, with higher levels during singing and cognitively demanding tasks, whereas PM and TVOC showed little variation by activity type. Overall, the results indicate that CO2 is useful for assessing occupancy and ventilation adequacy, but is not a reliable proxy for PM and VOCs in classrooms.

    2026
    引用
    AI阅读
    加入学术空间
    3Interior Paint Alters the VOC Emission Behaviors in Wildfire-Smoke-contaminated Drywalls
    Rachel Hurley,Anita Avery,Manjula Canagaratna,Albert Simeoni,Shichao Liu,Chenyang Bi

    While wildfire smoke is a known health hazard, it is overlooked how indoor surfaces prolong volatile organic compound (VOC) exposure. Indoor VOCs sorb into porous building materials and emit for weeks or months, making them difficult to remove via air cleaning. Despite indoor prevalence of painted drywall, the impact of paint on smoke VOC uptake and emission remains unclear. We experimentally evaluate peak emission rate and emission timescale of VOCs in smoke-exposed drywalls, examining the influence of material porosity, with and without a paint layer, and chemical vapor pressure. Using a sandwich style rapid-emission chamber and Vocus CI-ToF with NH₄⁺ as the reagent ion, we measured the emission for 23 VOCs from smoke-contaminated aluminum, drywall, and painted drywall samples, with their porosity and layer thickness quantified by micro-computed tomography. Painted and unpainted drywall displayed large capacities to sorb and emit wildfire smoke-sourced VOCs, with peak concentrations two orders of magnitude larger than the impervious reference aluminum. By comparing smoke-exposed drywall with and without the paint layer peeled, we demonstrate that paint may act as a selective barrier: the diffusion of lower-volatility species may be more inhibited by the paint surface, while more volatile compounds diffuse into the gypsum core, with the extent of penetration exhibiting a log-linear vapor pressure dependence. Future work will further investigate this behavior during more prolonged soaking periods and uniform soaking concentrations.

    2026
    引用
    AI阅读
    加入学术空间
    4Adjoint-based Corrective Approach for Nodal Indoor Air Quality Predictions
    Nicolas Carnec, Martin Ferrand,Thierry Duforestel, Bénédicte Wall-Ribot,Marc Abadie,Karim Limam

    Indoor Air Quality (IAQ) modelling in building simulations often relies on the nodal approach to evaluate exposure to airborne pollutants. This approach assumes perfect mixing within each zone, which can lead to significant discrepancies compared to CFD predictions, especially under complex airflow configurations. To address this limitation, this study proposes a correction model that modifies the nodal scalar mass balance using a correction factor derived from CFD results. These factors are designed to recover CFD-based spatial average concentrations at steady state while preserving scalar mass conservation through consistency with steady state CFD outlet scalar mass fluxes. To limit the computational cost, an adjoint scalar transport approach is used, enabling the computation of correction factors for all possible emission positions from a number of CFD simulations only equal to twice the number of outlets, for a given geometry and airflow configuration. The method is evaluated on a multizone residential case under isothermal conditions. The results show that the proposed approach significantly improves the prediction of mean concentrations compared to the classical nodal approach, while maintaining a much lower computational cost than forward CFD simulations. Residual discrepancies are mainly associated with transient behaviour, due to the simplified dynamics of the nodal formulation. These results highlight the potential of the method for improving scalar concentration predictions in practical isothermal applications, while also emphasizing that the correction factors remain dependent on the airflow configuration.

    2026
    引用
    AI阅读
    加入学术空间
    5An Innovative Desk Push-Pull Device for Reducing Airborne Contaminant Exposure in Office Environments
    Ihab Jabbar Al-Rikabi,Jennifer Karam,Conrad Voelker,Nesreen Ghaddar,Hayder Alsaad

    Most human-centred ventilation devices aim to reduce cross-contamination by targeting the breathing zone, potentially causing contaminant accumulation and spread into the surrounding area. This study introduces a novel desk push-pull system (Desk_PPS) that aims to reduce contaminant transfer within the occupant microenvironment. The device employs two perforated plates on each side of the desk: one supplies clean air while the other extracts contaminated air, establishing a clean-air barrier that minimizes contaminant exchange between the occupant's microenvironment and surroundings. A computational fluid dynamics model was developed to predict contaminant spread, with the flow-inducing device model experimentally validated. A parametric analysis was conducted to optimize the Desk_PPS for face-to-face and side-to-side sitting configurations, focusing on operating flowrate and perforation diameter. Cross contamination was quantified using intake fraction (IF). The Desk_PPS substantially reduced exposure relative to the No Desk_PPS case. In the face-to-face setup, the lowest IF values occurred at 54 l/s: 2.56 × 10⁻⁴ and 2.41 × 10⁻⁴ for 5 mm and 10 mm perforations, corresponding to reductions of 60% and 62%, respectively. The 5 mm perforation generated a narrower, higher-momentum jet that better confined contaminants near the source and reduced downstream accumulation near the exhaust, whereas the 10 mm perforation produced a broader flow field creating a larger low-contaminant zone around the exposed occupant, particularly at 43–54 l/s. In the side-to-side configuration, IF fell from about 7.1 × 10⁻⁴ without Desk_PPS to 1.9 × 10⁻⁴ at 54 l/s for 5 mm diameter, a 73% reduction. Overall, Desk_PPS performance depends on the interaction between flowrate, perforation diameter, and room-scale contaminant transport.

    2026
    引用
    AI阅读
    加入学术空间
    立即登录,查看全部 194 篇论文

    高被引作者

    作者引用发文
    Gabriel Bekö92
    Marzenna R. Dudzinska82
    Nicola Carslaw81
    Coralie Schoemaecker81
    Xavier Querol81
    David Shaw81
    Kati Huttunen81
    P. Wiesen81
    Sascha Nehr82
    Victor G. Mihucz81

    高产作者

    作者引用发文
    Stefano Schiavon35
    Ulla Haverinen-Shaughnessy55
    Chun Chen15
    Thomas Parkinson35
    Motoya Hayashi04
    Toyinbo Oluyemi24
    William W Delp03
    Matias Cesari03
    Tunga Salthammer73
    Martin Taubel73

    相关期刊

    暂无数据
    暂无数据