Abstract Unicuspid aortic valve (UAV) is a rare congenital anomaly, frequently associated with early progression to severe aortic stenosis and aortopathy. We report the case of a 38-year-old woman who presented with difficult-to-control hypertension and progressive exertional dyspnea. Transthoracic echocardiography revealed critical aortic stenosis (peak gradient of 183 mmHg, mean gradient of 125 mmHg, and valve area of 0.59 cm2), associated with mild aortic regurgitation and ascending aortic dilation (45–46 mm). Three-dimensional transesophageal echocardiography confirmed a unicommissural UAV, as well as an ostium secundum atrial septal defect with a left-to-right shunt (Qp/Qs = 2.3). Given the significant hemodynamic impact, aortic valve replacement with a bioprosthetic valve was performed. The patient developed a conduction disturbance during the postoperative period, requiring permanent pacemaker implantation. At the 6-month follow-up, she was asymptomatic, and the prosthetic valve was functioning normally. This case illustrates the importance of advanced echocardiography in identifying rare valvular anomalies and highlights the uncommon association between UAV, aortopathy, and atrial septal defect in a young woman, with relevant implications for clinical and surgical management.
Resumo A válvula aórtica unicúspide (VAU) é uma anomalia congênita rara, frequentemente associada à evolução precoce para estenose aórtica grave e aortopatia. Relata-se o caso de paciente feminina, 38 anos, com hipertensão arterial sistêmica de difícil controle e dispneia progressiva aos esforços. O ecocardiograma transtorácico evidenciou estenose aórtica crítica (gradiente máximo de 183 mmHg, médio de 125 mmHg e área valvar de 0,59 cm2), associada à regurgitação aórtica discreta e dilatação da aorta ascendente (45–46 mm). O ecocardiograma transesofágico tridimensional confirmou VAU do tipo unicomissural, além de comunicação interatrial tipo ostium secundum com shunt esquerda-direita (Qp/Qs = 2,3). Devido à repercussão hemodinâmica significativa, foi realizada substituição valvar aórtica com prótese biológica. Evoluiu com distúrbio de condução no pós-operatório, necessitando implante de marcapasso definitivo. No seguimento de 6 meses, apresentava-se assintomática, com prótese normofuncionante. Este caso ilustra a importância da ecocardiografia avançada na identificação de anomalias valvares raras e destaca a associação incomum entre VAU, aortopatia e comunicação interatrial em paciente adulta jovem, com implicações relevantes para o manejo clínico e cirúrgico.
Abstract Mitral regurgitation (MR) with multiple jets is a highly complex diagnostic scenario, frequently encountered in Barlow disease and functional phenotypes associated with ventricular remodeling. Conventional two-dimensional methods (e.g., vena contracta width, color jet area, and hemispheric proximal isovelocity surface area) have important limitations in the presence of multiple regurgitant orifices, eccentric jets, the Coanda effect, overlap of flow convergence zones, or noncircular annular geometry, which may lead to underestimation of volume overload. Three-dimensional echocardiography overcomes part of these limitations by enabling en face characterization of the mitral valve, planimetric measurement of the vena contracta area using multiplanar reconstruction, and the application of volumetric methods based on directly measured anatomical areas. The three-dimensional continuity equation (3D-CE), particularly in mitral valve prolapse and Barlow disease, has demonstrated promising agreement with the regurgitant volume measured using cardiac magnetic resonance (CMR); however, the available evidence should still be interpreted in the context of recent studies and patient populations. CMR remains the reference standard for volumetric assessment when echocardiographic findings discord with the clinical presentation, acoustic windows are suboptimal, or pre-interventional decision-making involves borderline parameters. This review proposes a hierarchical, multiparametric, and technically reproducible approach for assessing MR with multiple jets.
Resumo A insuficiência mitral (IM) com múltiplos jatos representa um cenário de alta complexidade diagnóstica, frequente na doença de Barlow e em fenótipos funcionais por remodelamento ventricular. Os métodos bidimensionais convencionais, incluindo largura da vena contracta (VCW), área do jato colorido e PISA hemisférico, apresentam limitações relevantes quando há orifícios múltiplos, jatos excêntricos, efeito Coanda, zonas de convergência sobrepostas ou geometria anular não circular, com possível subestimação da sobrecarga volumétrica. A ecocardiografia tridimensional (eco 3D) reduz parte dessas limitações ao permitir caracterização en face da valva, planimetria da área da vena contracta (VCA) por reconstrução multiplanar (MPR) e aplicação de métodos volumétricos com áreas anatômicas diretamente medidas. A equação de continuidade 3D (3D-CE), especialmente em prolapso mitral/Barlow, mostrou concordância promissora com o volume regurgitante (VR) por ressonância magnética cardíaca (CMR), embora sua evidência ainda deva ser interpretada no contexto de estudos recentes e amostras selecionadas. A CMR permanece referência volumétrica quando há discordância eco-clínica, janela acústica limitada ou decisão pré-intervenção com parâmetros limítrofes. Esta revisão propõe uma abordagem hierarquizada, multiparamétrica e tecnicamente reprodutível para avaliação da IM com múltiplos jatos.
Abstract Point-of-care ultrasound (POCUS) is one of the most significant innovations in contemporary cardiovascular clinical practice, serving as an extension of the bedside physical examination. This executive summary outlines the Position Statement from the Department of Cardiovascular Imaging of the Brazilian Society of Cardiology (DIC-SBC), published in 2026, covering the key domains of cardiovascular POCUS application: cardiac assessment, lung ultrasound, assessment of systemic venous congestion (VExUS), screening for deep vein thrombosis, management of circulatory shock, short-term mechanical circulatory support, emergency medicine applications, cardiorespiratory arrest, and ultrasound-guided procedures. Fundamental concepts regarding training, certification, and ethical and legal aspects relevant to the Brazilian context are discussed. This document emphasizes that POCUS does not replace a comprehensive diagnostic echocardiogram, but rather adds substantial clinical value when performed by properly trained professionals within structured protocols.