
This study used a combination of zonal elution and frontal affinity chromatography on immobilized human serum albumin (HSA) high-performance affinity chromatography (HPAC) column to examine the association constants of various compounds that have been studied by equilibrium dialysis or ultra filtration. A standard plot was generated from retention factors of reference compounds using zonal elution chromatography against association constants of reference compounds using frontal affinity chromatography. The linear relationship was established (r2=0.9993) between retention factors and association constants of reference compounds. This standard plot was later used for rapid determination of association constants of various drugs which show low to medium binding affinity to HSA. Association constants of those drugs from this study were compared to that of more generally used methods (i.e., equilibrium dialysis or ultra filtration) from literature and resulted in a relatively high correlation (r2=0.945) value. This combination of zonal elution and frontal affinity chromatography method for determining association constants showed several advantages against traditional methods. Depending on drugs of interest, an association constant of drug to HSA can be measured as fast as 1.5 min. Other notable advantages include an ease of automation and its ability to distinguish association constants of chiral compounds at the same time. The same approach could be used for studying interaction of other drugs and proteins and should further improve overall drug screening process.
A liquid chromatographic (LC) method for determining 14 sulfonamide (SA) (sulfanilamide, sulfadiazine (SDZ), sulfathiazole, sulfapyridine, sulfamerazine (SMR), sulfamethazine (SMZ), sulfamethizole, sulfamethoxypyridazine, sulfachloropyridazine (SCP), sulfamonomethoxine, sulfadoxine, sulfamethoxazole, sulfadimethoxine (SDM), and sulfaquinoxaline (SQX)) residues in edible catfish, shrimp and salmon tissues was developed and validated at 5, 10 or 20 ng g(-1). The method was then used to determine residues in tissues of catfish, shrimp and salmon dosed with six selected sulfonamides (sulfadiazine, sulfamerazine, sulfamethazine, sulfachloropyridazine, sulfadimethoxine and sulfaquinoxaline). All assays were within U.S. Food and Drug Administration guidelines for recovery and intra-assay variability. The method was developed to determine possible sulfonamide residues in aquacultured catfish, shrimp and salmon produced for food.
We propose a method for the simultaneous determination of hippuric acid (HA) and creatinine based on capillary micellar electrokinetic chromatography. Experimental conditions were 20 mM sodium phosphate, pH 7.20, 25 mM sodium dodecyl sulfate, 5% (v/v) acetonitrile. Electropherograms evidenced HA and creatinine peaks in less than 12 min. The method showed good linearity for both analytes and satisfactory within-day precision. The present method, which is accurate, sensitive, rapid and simple, may be applied to single-spot urine samples.
Zilpaterol is an adrenergic drug currently licensed in Mexico and South Africa as a feed additive for cattle close to consignment. In this study an analytical method to detect zilpaterol in commercial feeds was set up. The influence of extraction solvent and matrix was evaluated. The drug as a trimethylsilyl derivative was characterized by GC–MS, on a quadrupole detector, in the electron impact mode. Acidic extraction, solid-phase extraction C18 non-endcapped clean-up and mass characterization on ions m/z 308, 291, 405, 390 provided zilpaterol recoveries >75.3% and repeatability <3.3% in feeds spiked in the range 30.0–120.0 ng/g. The limits of detection and quantification were 7.5 and 25.0 ng/g, respectively. Such limits are well below the dose of 5.0–20.0 μg/g proposed as effective.
A validated method for the quantification of Δ9-tetrahydrocannabinol (THC) and its main metabolites 11-hydroxy-tetrahydrocannabinol (OH-THC) and 11-nor-9-carboxy-tetrahydrocannabinol (THC-COOH) in serum is presented. The substances were isolated by solid-phase extraction, derivatised by methylation, and analysed by means of GC–MS in the selected ion monitoring mode. Quantitation was achieved by the addition of deuterated analogues as internal standards. The method was linear up to 10 ng/ml for THC and OH-THC, and up to 50 ng/ml for THC-COOH. The limits of quantification were 0.62 ng/ml for THC, 0.68 ng/ml for OH-THC and 3.35 ng/ml for THC-COOH. The limits of detection for the least intensive ions were 0.52 ng/ml for THC, 0.49 ng/ml for OH-THC and 0.65 ng/ml for THC-COOH. The method was validated according to the requirements of the Journal of Chromatography B. The method has been routinely used on samples from drivers suspected of “driving under the influence”. In addition to the forensic application, a cross-validation was carried out by applying the method developed for serum to human liver microsomal preparation samples.
Cyanide (CN), a chemical asphyxiant, is a rapidly acting and powerful poison. We have developed a sensitive, rapid, simple, and fully automated method for measuring CN in whole blood. The assay is based on the use of gas chromatography (GC) with nitrogen-phosphorus detection and acetonitrile as an internal reference. Following the automated addition of phosphoric acid to the blood sample, the released hydrogen cyanide is analyzed using a fully automated headspace GC system. The assay, validated on human blood samples spiked with potassium cyanide and on clinical samples from fire victims who had smoke inhalation injury, can detect CN at a wide range of concentrations (30-6000 microg/l) in about 17 min (including incubation and GC run time, and <2 min for manual sample preparation). This automated, high-throughput, simple, and sensitive method is suitable for the rapid diagnosis of CN in clinical and forensic specimens.
This paper reviews several procedures for determination of mercapturic acids in urine. Special attention was paid to methods useful in relation to human exposure to industrial pollutants, without any description for less sensitive methods used in animal research. Gas chromatographic and liquid chromatographic procedures were considered together with the little information available about thin layer chromatography and immunochemical techniques. After a description of the main industrial pollutants which lead to synthesis of their specific mercapturic acids, the methods for analysing these products are synthetically reported. The comparison among difficulties in sample preparation, complexity of instrumentation and their cost/benefit ratio are discussed.
A polyvalent, lytic phage display system (T7Select415-1b) displaying a random peptide library has been investigated for its ability to discover novel mimotopes reactive with the therapeutic monoclonal antibody C595. Sequence analysis of enriched phage lead to the identification of a predominant sequence RNREAPRGKICS, and two other consensus sequences RXXP and RXP. The novel synthetic peptide RNREAPRGKICS was linked to beaded agarose and the performance as a mimotope affinity chromatography matrix evaluated. Antibody purified using the novel matrix was found to be of higher specific reactivity than antibody purified using the conventional epitope matrix (peptide APDTRPAPG). The RNREAPRGKICS peptide binding to C595 demonstrated a higher equilibrium association constant (KA=0.75×106) than the epitope peptide (KA=0.16×106). Circular dichroism showed that the novel peptide had a more highly ordered structure at 4°C and room temperature, than the epitope peptide.
A reversed-phase HPLC method with diode-array detection was used to simultaneously determine retinol, α-tocopherol and β-carotene in human plasma and low-density lipoproteins. An aliquot of sample was de-proteinized with ethanol containing α-tocopherol acetate as internal standard, and the analytes were extracted twice with hexane. The solvent was evaporated to dryness under a stream of nitrogen and the residue was redissolved in methanol to be injected directly into the HPLC system. A multiple solvent system based on methanol, butanol and water at a flow-rate of 2 ml/min and held at 45°C provided clear separation of these compounds in only 8 min. The method showed good linearity, precision and accuracy for all compounds. Owing to its simplicity, this method may be useful in routine clinical and epidemiological work.
A sensitive and selective assay for the determination of N-[1(R)-[(1,2-dihydro-1-methylsulfonylspiro[3H-indole-3,4'-piperidin]-1'-yl)carbonyl]-2-(phenylmethoxy)-ethyl]-2-hydroxyamino-2-methylpropanamide (I), a hydroxyl amine metabolite of a novel growth hormone secretagouge (II) has been developed utilizing high-performance liquid chromatography with ion spray tandem mass spectrometric detection (HPLC-MS-MS). The analyte and an internal standard (III) were isolated from the basified biological matrix using a liquid-liquid extraction with methyl tert.-butyl ether (MTBE). The organic extract was evaporated to dryness at room temperature. The residue was reconstituted in the mobile phase and injected into the HPLC-MS-MS system. Multiple reaction monitoring using the precursor-->product ion combinations of m/z 545-->267 and 543-->267 was used to quantify I and III, respectively, after chromatographic separation under isocratic conditions. The assay was validated in the concentration range of 0.5 to 500 ng/0.1 ml in both human and dog plasma. The precision of the assay, expressed as relative standard deviation, was less than 10% over the entire concentration range with the exception of the low concentration of 0.5 ng/0.1 ml which was 14.0% for human plasma. The HPLC-MS-MS method provided sufficient sensitivity to completely map the pharmacokinetic time course of I following a single 5 mg dose of II to human subjects and a 0.5 mg/kg dose to beagle dogs.
A liquid chromatographic-tandem mass spectrometric (LC-MS-MS) method with a rapid and simple sample preparation was developed for the determination of scopolamine in biological fluids. Scopolamine and the internal standard atropine in serum samples were extracted and cleaned up by using an automated solid phase extraction method. Microdialysis samples were directly injected into the LC-MS system. The mass spectrometer was operated in the multi reaction monitoring mode. A good linear response over the range of 20 pg/ml to 5 ng/ml was demonstrated. The accuracy for added scopolamine ranged from 95.0 to 104.0%. The lower limit of quantification was 20 pg/ml. This method is suitable for pharmacokinetic studies.
A HPLC-based method for quantifying glutathione, cysteine and cysteine-containing peptide is described. N-(2,4-Dinitrophenylaminoethyl)maleimide was synthesized from ethylenediamine, 2,4-dinitrochlorobenzene and maleic anhydride. The maleimide was reacted at 40 degrees C and pH 5.8 for 10 min with thiol compounds such as glutathione or cysteine. An aliquot of the reaction mixtures was applied to a reversed-phase column (4.6 x 150 mm) of HPLC. When glutathione and cysteine were simultaneously assayed, the column was eluted with a gradient of acetonitrile in potassium phosphate (pH 7.0). The derivatives were monitored at 350 nm. Good liner relationships existed between peak area and concentration of glutathione or cysteine from 10 pmol to 2 nmol. The recovery tests from rat liver homogenate were 99.7+/-2.2% for glutathione and 104.9+/-3.8% for cysteine. By this method gamma-glutamylcysteine, cysteinylglycine, and homocysteine could be also quantified. The determination limits of glutathione, cysteine and other thiol compounds were 5 pmol. The method is simple: a sample solution is mixed with the labelling reagent and an aliquot of the reaction mixture is applied to a standard HPLC. The hepatic levels of cysteine and glutathione in pre-cancerous rats were determined by this method. The cysteine level in pre-cancerous livers was extremely elevated in comparison to that of the control groups, while no difference was observed in the glutathione contents between the pre-cancerous and control groups.
Celecoxib is a cyclooxygenase-2 specific inhibitor, that has been recently and intensively prescribed as an anti-inflammatory drug in rheumatic osteoarthritis. A robust, highly reliable and reproducible liquid chromatographic-mass spectrometric assay is developed for the determination of celecoxib in human plasma using sulindac as an internal standard. The run cycle-time is <4 min. The assay method involved extraction of the analytes from plasma samples at pH 5 with ethyl acetate and evaporation of the organic layer. The reconstituted solution of the residue was injected onto a Shim Pack GLC-CN, C18 column and chromatographed with a mobile phase comprised of acetonitrile-1% acetic acid solution (4:1) at a flow-rate of 1 ml/min. The mass spectrometer (LCQ Finnigan Mat) was programmed in the positive single-ion monitoring mode to permit the detection and quantitation of the molecular ions of celecoxib and sulindac at m/z 382 and 357, respectively. The peak area ratio of celecoxib/sulindac and concentration are linear (r2>0.994) over the concentration range 50-1000 ng/ml with a lowest detection limit of 20 ng/ml of celecoxib. Within- and between-day precision are within 1.58-4.0% relative standard deviation and the accuracy is 99.4-107.3% deviation of the nominal concentrations. The relative recoveries of celecoxib from human plasma ranged from 102.4 to 103.3% indicating the suitability of the method for the extraction of celecoxib and I.S. from plasma samples. The validated LC-MS method has been utilized to establish various pharmacokinetic parameters of celecoxib following a single oral dose administration of celecoxib capsules in two selected volunteers.
Methods for the determination of 3,4-dichloroaniline (3,4-DCA) and 3,5-dichloroaniline (3,5-DCA) as common markers of eight non-persistent pesticides in human urine are presented. 3,5-DCA is a marker for the exposure to the fungicides vinclozolin, procymidone, iprodione, and chlozolinate. Furthermore the herbicides diuron, linuron, neburon, and propanil are covered using their common marker 3,4-DCA. The urine samples were treated by basic hydrolysis to degrade all pesticides, metabolites, and their conjugates containing the intact moieties completely to the corresponding dichloroanilines. After addition of the internal standard 4-chloro-2-methylaniline, simultaneous steam distillation extraction (SDE) followed by liquid-liquid extraction (LLE) was carried out to produce, concentrate and purify the dichloroaniline moieties. Gas chromatography (GC) with mass spectrometric (MS) and tandem mass spectrometric (MS-MS) detection and also detection with an electron-capture detector (ECD) after derivatisation with heptafluorobutyric anhydride (HFBA) were employed for separation, detection, and identification. Limit of detection of the GC-MS-MS and the GC-ECD methods was 0.03 and 0.05 microg/l, respectively. Absolute recoveries obtained from a urine sample spiked with the internal standard, 3,5-, and 3,4-DCA, ranged from 93 to 103% with 9-18% coefficient of variation. The three detection techniques were compared concerning their performance, expenditure and suitability for their application in human biomonitoring studies. The described procedure has been successfully applied for the determination of 3,4- and 3,5-DCA in the urine of nonoccupationally exposed volunteers. The 3,4-DCA levels in these urine samples ranged between 0.13 and 0.34 microg/g creatinine or 0.11 and 0.56 microg/l, while those for 3,5-DCA were between 0.39 and 3.33 microg/g creatinine or 0.17 and 1.17 microg/l.
Hepatitis B virus core protein (HBc) is an important serology marker of hepatitis B infection and patient follow-up. It is an M, 21,000 protein, which has the intrinsic capacity to self-assemble as a capsid-like particle. The hepatitis B core protein has been expressed in Escherichia coli and Pichia pastoris (three different constructions) in order to select a HBc recombinant antigen suitable for serodiagnosis requirements with a cost effective downstream strategy. The expression and purification of the different forms of recombinant HBc have been described. For the last step, ultracentrifugation and size-exclusion chromatography were compared. The morphology of these capsids was observed using an electron microscope. Our data shows that HBc antigen is produced in large quantities in E. coli but some contaminants remained which were associated with the E. coli HBc protein after ultracentrifugation or size-exclusion chromatography. The ultracentrifugation enables a higher purity of HBc antigen to be obtained than size-exclusion chromatography but the latter enables a higher recovery rate. P. pastoris enables the expression and extraction of a highly purified HBc antigen suitable for diagnostic purposes.
The main oral drug absorption barriers are fluid cell membranes and generally drugs are absorbed by a passive diffusion mechanism. Biopartitioning micellar chromatography (BMC) is a mode of micellar liquid chromatography that uses micellar mobile phases of Brij35 under adequate experimental conditions and can be useful to mimic the drug partitioning process in biological systems. In this paper the usefulness of BMC for predicting oral drug absorption in humans is demonstrated. A hyperbolic model has been obtained using the retention data of a heterogeneous set of 74 compounds, which shows predictive ability for drugs absorbed by passive diffusion. The model obtained in BMC is compared with those obtained using the well-known systems (Caco-2 and TC-7) that use intestinal epithelium cell lines. The use of BMC is simple, reproducible and can provide key information about the transport properties of new compounds during the drug discovery process.
A single HPLC assay was developed for therapeutic drug monitoring of 5 HIV protease inhibitors (indinavir, amprenavir, saquinavir, ritonavir, nelfinavir) and a non-nucleoside reverse transcriptase inhibitor (nevirapine) in human plasma. After liquid–liquid extraction in a mixture ethyl acetate–hexane, compounds are separated on a C18 column with a gradient elution of solvent A [acetonitrile and 0.025 M tetramethylammonium perchlorate in 0.2% aqueous trifluoroacetic acid (55:45 (v/v))] and solvent B [methanol and 0.025 M tetramethylammonium perchlorate in 0.2% aqueous trifluoroacetic acid (55:45 (v/v))]. The compounds are detected at various wavelengths: 320 nm (nevirapine), 259 nm (indinavir), 254 nm (amprenavir, nelfinavir, saquinavir) and 239 nm (ritonavir). The intra-day and inter-day precision and accuracy are lower than 15%. The limits of quantitation are 0.05 mg/l (amprenavir), 0.2 mg/l (indinavir, saquinavir, nelfinavir) and 0.4 mg/l (ritonavir, nevirapine). This method which allows to estimate simultaneously plasma levels of protease inhibitors and nevirapine can be used for therapeutic drug monitoring.
A narrow-bore normal-phase high-performance liquid chromatography (HPLC) method was developed for separation of phospholipid classes in human blood. The separation was obtained using an HPLC diol column and a gradient of chloroform and methanol with 0.1% formic acid, titrated to pH 5.3 with ammonia and added 0.05% triethylamine. The HPLC system was coupled on-line with an electrospray ionisation ion-trap mass spectrometer. Chromatographic baseline separation was obtained between phosphatidylglycerol, phosphatidylcholine, phosphatidylethanolamine, lyso-phosphatidylcholine, phosphatidylinositol and phosphatidylserine, eluting in that order. The total run time was 30 min. Plasmalogen phosphatidylethanolamine and sphingomyelin, which both are substances with structural similarities to the glycerophospholipids, had similar retention time as phosphatidylethanolamine, but were well separated from the other glycerophospholipid classes. The species from each class were identified using MS2 or MS3, which forms characteristic lyso-fragments. The combination of lyso-fragment mass, molecular ion and chromatographic retention time was used to identify each species, including 20 species of phosphatidylglycerol. The mass spectra obtained for the phospholipid classes are presented. Using this system 17 disaturated phospholipid species not earlier described to be present in blood were identified. The limit of detection varied between different phospholipid classes and was in the range 0.1–5 ng of injected substance.
In order to clarify arginine (Arg) metabolism by rumen microorganisms and by the tissues of ruminant animals, a convenient method for the simultaneous determination of Arg, citrulline (Cit), ornithine (Orn), proline (Pro) and 5-aminovaleric acid (5AV), and 4-aminobutyric acid (4AB) and lysine (Lys), incidentally, in goat rumen fluid was established by reversed-phase high-performance liquid chromatography (RP-HPLC). The separation was carried out by stepwise isocratic elution with two mobile phases (solvent A and solvent B) on a LiChrospher 100 RP-18 column (150x4.6 mm I.D., 5 microm particle size) equipped with a guard column (4.0x4 mm, 5 microm particle size). Solvent A is composed of acetonitrile-sodium citrate buffer (pH 7.2) (15:85, v/v) containing tetrahydrofuran (5 ml/100 ml), with solvent B comprising acetonitrile-sodium citrate buffer (pH 5.4) (40:60, v/v). Five compounds (Cit, Arg, Pro, 4AB and 5AV) were separated within 33 min in solvent A and the other two (Orn and Lys) in solvent B. Solvent A was automatically switched to solvent B with the help of a valve controller. Complete separation needs 62 min after sample injection in a single chromatogram. Samples were derivatized with 9-fluorenylmethyloxycarbonyl chloride (FMOC-Cl) and detected on a fluorescence detector at excitation and emission wavelengths of 263 and 611 nm, respectively. The minimum detectable concentrations (microM) (signal-to-noise ratio, S/N 3:1) of these compounds were: 0.65 for Cit, 0.65 for Arg, 1.9 for Pro, 1.3 for 4AB, 1.9 for 5AV, 0.12 for Orn and 0.48 for Lys. When applied to rumen fluid from goats, recoveries of all compounds added to the rumen fluid were 96.6-100.6% for an intra-day study and 93.9-99.4% for inter-day (5 days) studies. The average contents of Orn, 5AV and Lys in the rumen fluid of three goats before morning feeding were 7.3, 13.5 and 3.6 microM, but Cit, Arg, Pro, and 4AB were not found, although all these four compounds were detected 1 h after feeding. Pro (390 microM) and 5AV (497.6 microM) were highest 1 h after feeding and then decreased. Orn levels before morning feeding were most similar to those after feeding.
A selective and sensitive high-performance liquid chromatography (HPLC) method with fluorescence derivatization for the assay of guanylate cyclase (GC) activity is described. GTP and cGMP, which are the substrate and the product of GC, respectively, and other guanine-containing compounds are selectively converted by the reaction with (3,4-dimethoxyphenyl)glyoxal to the fluorescent derivatives. The derivatives were separated by reversed-phase HPLC. The limit of detection at a signal-to-noise ratio of 3 for cGMP was 10 fmol on the column. The sensitivity of this method was less than that of the conventional radioisotopic method, but this method is simple and convenient. Human platelet GC activity was measured, and the effects of some compounds were investigated.