This study investigates the use of near-infrared (NIR) spectroscopy as a non-destructive, real-time quality control tool for 3D-printed caffeine tablets produced via direct powder extrusion (DPE). The primary objective was to evaluate whether NIR spectral data could reliably predict key quality attributes including caffeine concentration, porosity, and dissolution behavior using chemometric modeling. Caffeine-loaded hydroxypropyl cellulose (HPC) formulations ranging from 0% to 20% caffeine were prepared and printed into tablets using a DPE-equipped 3D printer. Physical characterization included rheology, differential scanning calorimetry, bulk and true density measurements, and in vitro dissolution testing. NIR spectra were collected using both a benchtop NIR system and a miniature NIR device. Partial least squares regression was employed to correlate spectral variation with tablet quality attributes, achieving strong predictive performance for caffeine content (RMSEP = 0.6%), moderate performance for porosity (RMSEP = 2.4%), and early dissolution (RMSEP = 1.1% at 15 min), and poor accuracy for later dissolution time points. The miniature NIR device yielded comparable results to the benchtop system, supporting its feasibility for point-of-care implementation. These findings highlight the potential of NIR spectroscopy, particularly when paired with chemometric modeling, to enable rapid, non-invasive quality assessment of 3D-printed pharmaceuticals. Incorporating miniature NIR devices into 3D printing workflows offers a practical and potentially automated pathway to support decentralized pharmaceutical manufacturing, enabling real-time quality assurance for each print.
This research demonstrates the application of ruggedized, field-portable, commercial off-the-shelf Fourier transform infrared (FT-IR) technology for the presumptive on-scene analysis of latent ignitable liquid vapors following a fire. These controlled fire tests represent realistic fire scenarios that incorporate semi-quantitative vapor concentration assessments to guide the on-scene decisions of fire investigators about sample collection locations. A total of 32 ignitable liquid residue samples and eight comparison samples were collected across eight controlled burns and evaluated using the method described here. The results show that the FT-IR devices used in this study can reliably detect latent ignitable liquid vapors post-flashover and post-extinguishment at approximately 50 ppm isobutylene units, as determined by a commercial photoionization detector. A unique model of the FT-IR data can discriminate the measured spectra into two distinct petroleum distillate categories that align with the American Society for Testing and Materials classification of ignitable liquids for fire debris analysis. This work has significant implications for providing fire scene investigators with presumptive evidence to indicate whether specific liquids were present at a location for comparative purposes, to expedite suspect interviews, or to determine whether a criminal search warrant may be needed.
Selecting an optimal infrared sampling approach is critical to unlock the problem-solving capabilities of Fourier transform infrared (FT-IR) spectroscopy. This work evaluates how the physical state of the sample, the internal reflection element (IRE)/sample interface as well as differences between the sample and IRE refractive indices impact the attenuated total reflection (ATR) infrared spectral quality. Anomalous dispersion within infrared absorption bands has a critical effect on the ATR infrared spectral quality relative to classical transmission preparations. Using a single-bounce ATR accessory at 45° incidence, infrared spectra were acquired with diamond and Ge IREs and compared against transmission-based measurements (capillary films for liquids; Nujol mulls and KBr discs for solids). Liquid immersion oil standards spanning refractive index values of η = 1.45–1.70 were used to systematically examine refractive index effects in the ATR infrared spectra of the samples. Water was also examined as a liquid with lower refractive index (η = 1.33) but with very large absorbance values. Commonly encountered, industrially relevant inorganics species spanning refractive indices of η ≈ 1.45–2.5 were measured to assess the additional challenges of ATR infrared measurements of solid-state materials. Characteristic spectral distortions of ATR infrared spectra include baseline offsets and slope, anomalous-dispersion-based infrared band asymmetry and broadening and in extreme cases complete loss of diagnostic infrared bands. These effects were far less pronounced in liquids than in solid materials. The advantages of using higher refractive index IREs such as Ge are illustrated with application examples including carbon black-filled rubber crumb, inorganic-containing polyolefin roofing tile, and lyophilized mining pregnant leach solution. In these cases, Ge-ATR infrared spectral measurements consistently reduce anomalous dispersion-based spectral artifacts and improve spectral information content, resulting in significantly improved interpretability and digital library spectral matching compared with diamond-ATR FT-IR measurements.
Recent research in the fields of forensic and biological anthropology reveals that much can be gleaned from the elemental analysis of skeletal remains. This is a burgeoning area of analysis, however, and foundational studies on the elemental analysis of bones require representative remains, that is, de-fleshed bones from humans or animals. While manual de-fleshing can be straightforward, the precise cleaning of tissues from the bones requires more attention or the use of a maceration aid to break down flesh. Several maceration methods have been established that use detergent, enzymatic detergent, enzyme solution, heat, or invertebrates (specifically, flesh-eating beetles or Dermestes maculatus ) to de-flesh bones. These methods must be evaluated for potential chemical interference and effects on the bone matrix before they can be applied in the elemental analysis of skeletal remains. In this study, these maceration methods, as well as a “control” method that did not include the use of a maceration technique to aid in de-fleshing, were applied to a sample set of 54 porcine ribs. The effects of each maceration method on the bones’ chemical compositions were assessed using X-ray fluorescence (XRF), laser-induced breakdown spectroscopy (LIBS), and inductively coupled plasma mass spectrometry (ICP-MS). The effects of each maceration method on the bones’ physical matrices were assessed using spectrophotometry and digital microscopy. Each maceration aid is found to result in bones that are chemically distinct from the control group, but invertebrate maceration produces bones that most resemble the control group when analyzed via LIBS or ICP-MS, while enzymatic maceration produces bones that most resemble the control group when analyzed via XRF.
Eggshell membrane (ESM) extracts are widely utilized as bioactive biomaterials and nutraceuticals due to their rich content of structural proteins and glycosaminoglycans. Ensuring the compositional purity of these materials—specifically the degree of separation between the organic membrane and the inorganic, mineralized eggshell—is critical for processing efficacy and quality control. In this study, 1064 nm near-infrared Raman spectroscopy was employed for high-fidelity, nondestructive compositional analysis. Characteristic Raman signals for carbonate (1085 cm −1 ) and Amide I (1668 cm −1 ) were utilized to differentiate the inorganic shell and organic membrane phases. A robust linear calibration model (R 2 = 0.99) was established between Raman intensity ratios and known mass ratios using laboratory-prepared reference standards. Application of this quantitative methodology to representative consumer-grade ESM powders successfully estimated residual hard-shell mass percentages, demonstrating that 1064 nm Raman spectroscopy provides a rapid, reliable analytical framework for monitoring material purity in ESM processing and manufacturing.