• 学术搜索
  • 科研智能体
    • Research Labs
    • AI 阅读
    • AI 文库
    • 深度研究
    • 学者亮点
  • 学术资源
    • AI2000
    • 期刊/会议
    • 学者库
    • 学术API
      MCP&Skill
    • 溯源树
    • 数据集
  • 知识沉淀
    • 学术空间
订阅小程序
旧版功能
aminer vip
开通会员低至0.73元/天
一次搞定AI科研
立即登录
  • English
  • 联系方式
    BIOMATERIALS and BIOMECHANICS in BIOENGinEERinG

    BIOMATERIALS and BIOMECHANICS in BIOENGinEERinG

    JournalISSN 2465-9835eISSN 2465-9959

    年发文量

    研究主题

    论文(55)

    排序
    1Wave Behavior at the Interface of Inviscid Fluid and NL Bio-Thermoelastic Diffusive Media
    Rajneesh Kumar,Suniti Ghangas,Anil K. Vashishth

    This work throws light on the reflection and transmission phenomenon due to incident plane longitudinal wave at a plane interface between inviscid fluid half-space and a nonlocal bio-thennoelastic diffusive half-space. The governing equations are formulated by adopting nonlocal heat conduction and mass diffusion along with dual phase lag (DPL) model. The amplitude ratios are obtained analytically and these amplitude ratios are used to drive energy ratios. The distribution of energy of incident wave among reflected and transmitted waves are obtained. The obtained ratios are impacted by angle of incidence, frequency and different properties of media involved. Numerically examined energy ratios are displayed in the form of graphs to know the effect of nonlocal parameters, lagging times, stiffness and blood perfusion rate.

    2022引用:9
    引用
    AI阅读
    加入学术空间
    2Evaluation of the Use of PEEK Material in a Knee Joint Endoprosthesis Insert by FEM Analysis
    Wiktoria M. Wojnarowska,Slawomir Miechowicz,Tomasz Kudasik

    This study contains a comparative analysis of two polymers: PEEK and UHMWPE. A stress distribution pattern in a knee joint endoprosthesis insert was determined for both materials. A numerical model of the insert generated by means of the SOLIDWORKS software was used in calculations. For the purpose of the calculations it was assumed that the insert is loaded consistently and symmetrically, and the value of the load applied was determined for a person of a total weight of 120 kg.

    2022
    引用
    AI阅读
    加入学术空间
    3Finite Element Analysis of the Mechanical Behavior of the Different Angle Hip Femoral Stem
    Yilmaz Guvercin,Murat Yaylaci,Hasan Olmez,Ecren Uzun Yaylaci,Mehmet Emin Ozdemir,Ayberk Dizdar

    Femoral stems with proximal metaphyseal involvement are commonly used total hip replacement components with very good results. In this study, total hip arthroplasty (THA) application was analyzed using a three-dimensionally modeled human hip joint by finiite element method. The aim of the study is to investigate the effects of changes in the direction of the femoral stem on these complications. Finite element analysis is performed on a model of femur bone by varying the femur angles. Finite element models were prepared for three different positions (5 degrees varus, neutral, 5 degrees valgus) on the femur without cement during walking motions. A sinusoid dynamic load with amplitude between 300 N and 1700 N and with a frequency of 1 Hz was applied. The stresses, strains and deformations that occurred on the femur and stems were determined at the end of the finite element analysis and compared to each other. Considering the results of strain, strain and deformation in the study, it is seen that the closest results to the natural load bearing of the femur are in the valgus position. The results obtained in the neutral position are also close to these results. In the metaphyseal points involving the femur stem, the highest values were found in the varus position. In all three positions, the femoral stem provides the transfer of the load from the proximal femur. The lowest stress, strain and deformation results were obtained in the valgus position, especially in the metaphyseal where the prosthesis is involved. It is seen that there are values close to this in the neutral position. This situation may be thought to result in a decrease in the proximal stress shield, an increase in bone protection compared to the varus position, a long-term loosening and a decrease in periprosthetic fracture.

    2022引用:23
    引用
    AI阅读
    加入学术空间
    4Effect of Force During Stumbling of the Femur Fracture with a Different Ce-Mented Total Hip Prosthesis
    Zagane Mohammed El Sallah,Benouis Ali,Sahli Abderahmen

    Total hip prosthesis is used for the patients who have hip fracture and are unable to recover naturally. To de-sign highly durable prostheses one has to take into account the natural processes occurring in the bone. Finite element analysis is a computer based numerical analysis method which can be used to calculate the response of a model to a set of well-defined boundary conditions. In this paper, the static load analysis is based, by se-lecting the peak load during the stumbling activity. Two different implant materials have been selected to study appropriate material. The results showed the difference of maximum von Misses stress and detected the fracture of the femur shaft for different model (Chamley and Osteal) implant with the extended finite element method (XFEM), and after the results of the numerical simulation of XFEM for different was used in deter-mining the stress intensity factors (SIF) to identify the crack behavior implant materials for different crack length. It has been shown that the maximum stress intensity factors were observed in the model of Chamley.

    2020引用:8
    引用
    AI阅读
    加入学术空间
    5Modeling Free Vibration Analysis of Osteon As Bone Unite
    Farzad Ebrahimi,Farin Zokaee

    This paper investigated vibrational behavior of the osteon as bone unit in the different situations. This study can lead to increase our knowledge of our body. In this paper free vibration of the osteon with considering it as composite material has been studied. The effect of numbers of lamellae and radius of those on natural frequency of osteon are subtle; while thickness of lamellae have decreasing trend on natural frequency of osteon. The presence of nerve and blood in haversian canal change trend of natural frequency, absolutely. Using the nonlocal strain gradient theory (NSGT) leads to effectiveness of scale parameter on equations of motion and the obtained results. The governing equations are derived by Hamilton's principles. A parametric study is presented to examine the effect of various parameters on vibrational behaviour of osteon. The results can also be regarded as a benchmark in vibration analysis behavior of osteon as bone unite.

    2020引用:2
    引用
    AI阅读
    加入学术空间
    立即登录,查看全部 55 篇论文

    高被引作者

    作者引用发文
    Tarun Goswami312
    Fernando J Quevedo González271
    Natalia Nuño271
    Bharadwaj Cheruvu241
    Richard T. Laughlin241
    Lu Huang231
    Byeongmoon Jeong231
    Ecren Uzun Yaylaci231
    Murat Yaylacı231
    Wei He231

    高产作者

    作者引用发文
    Kazuhiko Ishihara83
    Mohsin Talib Mohammed142
    Bölgen Nimet72
    Seda Ceylan72
    Tarun Goswami312
    Farzad Ebrahimi42
    Antonio Ramos132
    Yoon Ki Joung132
    Farin Zokaee42
    Ali Benouis92

    相关期刊

    Journal of mechanics of materials and structures
    Curved and Layered Structures
    Romanian Journal of Acoustics and Vibration
    Journal of Solid Mechanics
    Coupled Systems Mechanics
    International Journal of Engineering and Applied Sciences
    Vietnam Journal of Mechanics
    European Journal of Computational Mechanics
    JOURNAL OF SANDWICH STRUCTURES & MATERIALS
    Mechanics of Advanced Composite Structures