Background: Sterile processing departments (SPDs) support safe surgical and procedural care through the cleaning, inspection, assembly, sterilization, storage, and distribution of reusable medical devices. Persistent staffing shortages can disrupt these functions and complicate onboarding of entry-level technicians. Methods: This descriptive program evaluation examined an SPD technician trainee program implemented across a multihospital health system. The SPD enterprise included approximately 216 full-time equivalent positions, and the program was developed to expand the technician pipeline and standardize onboarding during a period of workforce instability. The 10- to 13-week curriculum used a competency-based educational framework that combined didactic instruction, simulation, supervised clinical practice, competency validation, and certification preparation informed by Healthcare Sterile Processing Association (HSPA) educational content and ANSI/AAMI ST79:2017 principles. Results: Across seven cohorts, 92 trainees were selected and 88 completed the program (95.65% completion rate). Among completers, 63 applied for the HSPA's Certified Registered Central Service Technician examination and 51 passed (80.95% pass rate). Retention was lower, with 38 of 92 participants (41.3%) remaining in SPD roles at the time of analysis. Operational data also showed persistent baseline staffing strain and were used to assess vacancy trends and selected workflow indicators during implementation. Conclusion: A structured internal SPD training pathway was feasible to implement across a multihospital system and was associated with strong completion and certification outcomes. However, retention remained an important challenge, suggesting that training should be paired with broader workforce strategies focused on onboarding support, career development, and long-term workforce stability.
Water quality is a critical control variable for healthcare device processing and other high-purity applications. Many facilities rely on chemical treatments (e.g., salt-based softeners, sodium bisulfite for dechlorination), but these methods increase system complexity, generate chemical waste, and introduce risks to staff, patients, and downstream wastewater systems. These challenges are particularly noteworthy in healthcare settings, where both safety and environmental performance are tightly regulated. Filtration-based alternatives that reduce dependence on chemical dosing were evaluated in the current work. Technologies such as reverse osmosis, advanced carbon and particulate filtration, and ultraviolet or thermal disinfection could achieve high-purity water, including critical water, by removing dissolved ions, organics, particulates, and microorganisms. These approaches simplified operations, lowered chemical handling risks, and reduced waste generation while maintaining consistent water quality at a substantial cost reduction in equipment, installation, energy, and consumables. Through comparison of conventional chemical systems and low-chemical or chemical-free designs, the analysis showed that filtration-centered approaches can meet stringent performance requirements while improving safety, reliability, and sustainability. The findings supported the consideration of filtration-dominant water treatment as a practical, evidence-informed strategy to reduce chemical reliance, protect human health, and minimize environmental impact in healthcare facilities when implementation is supported by appropriate validation and monitoring.
Ultrasound probes, which are used routinely in clinical practice, can become contaminated after use. If not effectively processed, they may pose an infection control challenge. Understanding the extent to which microscopic surface topography of ultrasound probes may shield microorganisms is crucial, yet these features remain poorly characterized. This descriptive study used scanning electron microscopy (SEM) to investigate the microscopic topography of ultrasound probe surfaces. Characteristics such as grooves, notches, guide features, orientation markers, and seams were identified on endocavitary (n = 4) and surface (n = 1) probes. Gaps and crevices within these characteristics were assessed for their potential to harbor microorganisms. A total of 46 sites across 15 segments from the five ultrasound probes were examined using a tungsten-filament SEM under low vacuum at an accelerating voltage of 20 kV. Of the 46 sites imaged, 32 showed measurable gaps or crevices, with widths of 0.9 to 480.4 μm. The lens surface revealed microscopically rough texture with crevices as wide as 4.8 μm. Surface wear, such as a displacement scratch on an endocavitary probe shaft, had crevices large enough to shield pathogens. On probe shafts and handles, seam widths of 7.9 to 480.4 μm containing dried residue with gaps were observed. These gaps and crevices are large enough to harbor microorganisms and could be relevant when considering disinfection efficacy. These observations highlighted the relevance of probe surface microtopography as a consideration for future device processing research. Additional studies are needed to determine how cleaning and high-level disinfection processes interact with microscopic surface features across different ultrasound probe designs.
During the COVID-19 pandemic, many methods of decontamination were proposed to combat the severe shortages of disposable personal protective equipment (PPE), such as N95 respirators and gowns, for healthcare workers. Although several decontamination methods were granted emergency use authorizations for N95 respirators, no methods were granted for gowns. The main concerns for decontamination of disposable PPE are twofold. First, the method must adequately decontaminate the PPE, and second, the device must retain its performance requirements after decontamination. The current study examined autoclave sterilization and single-step gaseous ozone decontamination methods for decontaminating N95 respirators and gowns, while microwave-generated steam decontamination was also used for N95 respirators. We found that N95 respirators could undergo major deformation due to decontamination, but this deformation was not reflected in filtration efficiency, pressure drop measurements, or tensile strength measurements. These findings underscored the importance of other methods that define the protective performance of the product (e.g., fit testing) for assessing the impact of decontamination on N95 respirators. Surgical gowns maintained their protection level regardless of decontamination type, but not enough samples were tested for a proper acceptable quality level determination. For isolation gowns, autoclaving resulted in catastrophic material failure due to high heat, but the gentler decontamination method using gaseous ozone resulted in a lower failure rate for the material.
The current work demonstrated inactivation of bacterial endotoxin by moist heat, electron beam, and gamma irradiation in dry, water, and saline conditions relevant to medical devices and pharmaceuticals. This study was intended to help manufacturers decide whether to test for bacterial endotoxin pre- or poststerilization. It demonstrated the feasibility of inactivating endotoxin by widely available sterilization technologies other than dry heat.