"Editorial - Sound, British Journal of Audiology, International Journal of Audiology." British Journal of Audiology, 35(6), pp. 327–328
This paper describes a comparison of the electroacoustic characteristics of five hearing aids: (1) a linear BTE aid of the type dispensed under the UK National Health Service (NHS), the BE19; (2) an analogue programmable BTE aid incorporating two-channel wide dynamic range compression, the ReSound BT2; (3) and (4) two digital BTE aids incorporating multi-channel wide dynamic range compression, the Phonak Claro and the Danavox Danalogic; (5) a disposable ITE hearing aid with single-channel compression, the Songbird. Measurements of frequency response using a 2 cc coupler showed that the NHS aid had a distinct undesired peak around 1 kHz. The response rolled off at low and high frequencies, and no gain was applied above about 4000 Hz. The BT2 and Claro both showed somewhat irregular responses with effective upper frequency limits of 5000-6000 Hz. The Danalogic had a reasonably smooth response and provided gain up to 6000 Hz. The Songbird had a smooth response and provided gain up to about 7000 Hz. All aids showed reasonably low harmonic and intermodulation distortion (probably below audible levels for hearing-impaired listeners), the Phonak Claro being the best in this respect. Measures of the effective input noise were obtained using two new methods. The NHS aid had the highest (worst) effective input noise, whereas the Songbird had the lowest, especially at low frequencies. The BT2 and the two digital aids had similar noise levels on one measure, but the BT2 was superior on the other measure. The compression circuits were characterized by measuring attack and release times and by using a method described by Stone and Moore (1992). The aids varied markedly in the extent to which they compressed amplitude modulation at the rates typically occurring in speech (2-10 Hz), the Claro providing the least compression and the Danalogic and Songbird aids providing the most. Overall, the results indicate that the NHS aid performed more poorly in several respects than the other aids. There were no great differences in electroacoustic characteristics between the remaining analogue aids and the digital aids, although the Songbird had a somewhat wider frequency range and lower effective input noise than the other aids.
A series of experiments have been performed with the primary aim of assessing the performance of a signal-processing algorithm for a possible future hearing aid application. As part of this work the four alternative auditory feature (FAAF) test was used to obtain a quantitative assessment of speech intelligibility and a subjective assessment of speech quality. This paper reports results of experiments using normal hearing (NH) subjects that provide partial verification of the FAAF test originators' prior work. Also reported are intelligibility score, mean opinion score (MOS) and completion time data obtained by use of the
The influence of hearing loss and aging on the perceptual organization of sound sequences was investigated by comparing the ability of young normal-hearing subjects and elderly subjects having either impaired or normal hearing for their age to form perceptual auditory streams from sequences of harmonic complex tones as a function of differences in fundamental frequency (F0). The sequences consisted of repeating triplets of harmonic complex tones separated by a silence (ABA-). In conditions in which the F0s of the A and B tone were so low that the harmonics could not be individually resolved by the peripheral auditory system even in the young normal-hearing subjects, those subjects showed similar stream segregation performance to the elderly hearing-impaired subjects. In contrast, when the F0s of the tones were high enough for the harmonics to be largely resolved at the auditory periphery in normal-hearing subjects, but presumably unresolved in the elderly subjects, the former showed significantly more stream segregation than the latter. These results, which cannot be consistently explained in terms of age differences, suggest that auditory stream segregation is adversely affected by reduced peripheral frequency selectivity of elderly individuals. This finding has implications for the understanding of the listening difficulties experienced by elderly individuals in cocktail-party situations.