
Limited data exist regarding the real-world practices and clinical outcomes in patients with ischemic heart failure with reduced left ventricular ejection fractions (LVEFs). Using nationwide registry data from South Korea, we aimed to investigate long-term outcomes and clinical practices, especially implantable cardioverter defibrillators (ICDs) implantation, in patients with reduced LVEFs at least 40 days after acute myocardial infarction (AMI). Of 13,056 patients with AMI between 2011 and 2015, we analyzed 350 (median age, 66 years [interquartile range, 56-75]) who had LVEFs <40% on follow-up transthoracic echocardiogram 40 days after the index event. The primary outcome was cardiac-cause mortality at 3 years. Secondary outcomes comprised major cardiovascular events as well as outcomes defined by the use of ICDs, cardiac resynchronization therapy defibrillators (CRT-Ds), and electrophysiology studies. Among 350 patients, 39 (11.1%) died from cardiac causes during 3 years of follow-up. Eleven (3.1%) were hospitalized for ventricular tachycardia. The rate of ICD or CRT-D implantation up to 3 years was 5.7% (20/350). Cox time-to-event analysis revealed older age, LVEF <30%, diabetes mellitus, and previous MI or revascularization as positively associated with cardiac death, whereas the use of statins and body weight <67 kg were negatively associated. This nationwide Korean registry demonstrated that only 5.7% of patients who had reduced LVEFs after 40 days of AMI underwent ICD implantations over 3 years. Considering the high mortality, concerted efforts are needed to improve clinical outcomes for patients who may have been candidates for ICD implantation.
The interstitial cells of Cajal (ICC) generate spontaneous pacemaker activities responsible for producing slow waves in the gut smooth muscles. Prostaglandin E2 (PGE2) is one of the most important prostanoids in the gut, playing a crucial role in multiple physiological and pathological processes. Because information regarding the effects of PGE2 on colonic ICC is limited, we investigated the effects of PGE2 and its underlying signaling pathways in murine colonic ICC. Whole-cell patch-clamp recordings and reverse transcription polymerase chain reaction (RT-PCR) analyses were performed to evaluate the effects of PGE2 on mouse colonic ICC. PGE2 had a dual effect on pacemaker potential in the current-clamp mode. RT-PCR data suggested the expression of EP3 and EP4 receptors in colonic ICC. Low PGE2 concentrations induced membrane depolarization and generation of pacemaker activities. And this effect is mimicked by sulprostone (an EP3 agonist). The low PGE2 concentration-induced effect was inhibited by anoctamin-1 (ANO1) or a T-type Ca2+ channel blocker. Conversely, high PGE2 concentrations induced membrane hyperpolarization and blocked pacemaker potential generation. However, this inhibitory effect was blocked by an ATP-sensitive potassium (KATP) channel blocker but not by other K+ channel blockers. Low concentrations of PGE2 activated EP3 receptors, leading to excitation of pacemaker activity through regulation of ANO1 and T-type Ca2+ channels in colonic ICC. In contrast, higher concentrations of PGE2 activated EP4 receptors and opened ATP-sensitive K+ channels, resulting in inhibition of pacemaker activity in colonic ICC.