• 学术搜索
  • 科研智能体
    • Research Labs
    • AI 阅读
    • AI 文库
    • 深度研究
    • 学者亮点
  • 学术资源
    • AI2000
    • 期刊/会议
    • 学者库
    • 学术API
      MCP&Skill
    • 溯源树
    • 数据集
  • 知识沉淀
    • 学术空间
订阅小程序
旧版功能
aminer vip
开通会员低至0.73元/天
一次搞定AI科研
立即登录
  • English
  • 联系方式
    Eklem hastaliklari ve cerrahisi = Joint diseases & related surgery

    Eklem hastaliklari ve cerrahisi = Joint diseases & related surgery

    JournalISSN 1305-8282eISSN 1309-0313

    年发文量

    研究主题

    论文(938)

    排序
    1The Influence of Design Factors on the Mechanical Properties of Biodegradable Composite Plates: A Finite Element Analysis
    Mustafa Buğra Ayaz,Ali Çağrı Tekin,Süreyya Ergün Bozdağ,Serhat Gürbüz,Mehmet Kürşad Bayraktar, Esra Akdaş Tekin

    OBJECTIVES:This study aims to investigate the influence of implant design factors on mechanical behavior and to identify lower-profile biocomposite plate configurations with mechanical responses approaching those of a titanium reference construct under selected loading conditions. MATERIALS AND METHODS:In this computational finite element study, three-dimensional implant models were developed, and material properties of polyamide-6/nano-hydroxyapatite and titanium alloy (Ti6Al4V) were assigned. Seven composite plate types were modeled: flat (thicknesses 8, 9, and 10 mm), bellied, curved, enhanced, and hybrid plate. All constructs were mounted on a cylindrical synthetic femoral diaphyseal surrogate and fixed with six screws. Finite element analysis was conducted using ANSYS Mechanical 2022 R2 under axial compression (800 N), distraction (300 N), and torsion (10 Nm). Mechanical responses including maximum deformation, von Mises stress, and strain distribution in bone, plate, and screws were evaluated. Results were evaluated descriptively and comparatively across implant configurations and loading conditions. RESULTS:The titanium construct generally demonstrated the lowest deformation under torsional loading and the lowest plate strain response, whereas selected composite geometries approached or exceeded titanium-like deformation performance under specific loading modes. The hybrid plate showed the lowest deformation under compression, while the thick flat plate provided the lowest deformation among composites under distraction and torsion. The bellied design showed lower torsion-induced deformation and lower plate stress than most other lower-profile composite configurations. The enhanced plate exhibited the lowest plate strain among the composite models under compression and distraction but may pose challenges for soft tissue coverage due to its complex geometry. CONCLUSION:Optimizing plate geometry can substantially modify the mechanical behavior of biodegradable composite constructs. Hybrid and enhanced designs demonstrated load-mode specific mechanical responses that may inform future biodegradable plate optimization, particularly with further material refinement and experimental validation.

    2026
    引用
    AI阅读
    加入学术空间
    2Patient-specific 3D Printed Guides for Repairing Posterior Root Tears of the Medial Meniscus: A Cadaveric Study
    María Durán-Serrano, Ignacio Colom-Diaz,Antonio-Francisco Laclériga-Giménez, Daniel Delfau-Lafuente,Adrián Roche-Albero,Miguel Lizcano-Palomares,Carlos Martín-Hernández

    OBJECTIVES:The aim of this study was to evaluate the accuracy of tibial tunnel placement using patient-specific three-dimensional (3D)-printed guides for repairing medial meniscus posterior root tears designed from magnetic resonance imaging (MRI) scans. MATERIALS AND METHODS:Five right fresh-frozen cadaveric knees underwent MRI scanning with 1-mm isotropic slices. For each specimen, custom guides were created to generate two transosseous tibial tunnels, with design based on anatomical landmarks including the medial tibial eminence (MTE) and the posterior cruciate ligament (PCL) insertion. Guide design was done using Rhinoceros software, segmentation of bone structures and soft tissues in 3D Slicer, and printing in polyamide. After arthroscopic repair, computed tomography scans and anatomical dissections were performed to measure the accuracy of tunnel placement relative to the native medial meniscus posterior root attachment (MMPRA), the MTE, and the PCL. Individual pre- and postoperative measurements were compared to verify anatomical accuracy, and pooled data from all knees were analyzed. RESULTS:Individual evaluation showed minimal differences between pre- and postoperative measurements, ranging from 0.00 to 0.09 mm. Pooled analysis revealed no significant differences in the measurements taken: PCL-MMPRA (p = 0.313), MTEMMPRA (p = 0.705) or the width of MMPRA (p = 0.125). The guides enabled precise and reproducible tunnel placement, with consistent targeting of the anatomical footprint. Each guide cost approximately €30, with a production turnaround time of less than one week. CONCLUSION:Patient-specific 3D-printed guides enable the effective creation of two anatomically accurate tibial tunnels for medial meniscus posterior root repair. This approach offers a rapid and precise solution for anatomical restoration using MRI-guided planning.

    2025
    引用
    AI阅读
    加入学术空间
    3Reconstruction of Traumatic Forefoot Defects with Free Lateral Arm Flap
    Kubilay Erol, Can Yener,Erdem Er,Özgün Barış Güntürk,Tulgar Toros

    Objectives: This study aims to evaluate the results of traumatic soft tissue defects of the forefoot reconstructed using the lateral arm flap and to examine the advantages and disadvantages of this flap. Patients and methods: Between January 2007 and December 2023, a total of 25 patients (23 males, 2 females; median age: 35 years; range, 8 to 57 years) who underwent lateral arm free flap reconstruction for forefoot soft tissue defects were retrospectively analyzed. Age, sex, injury mechanism, flap size, anastomosis site, vascular complications, associated injuries, functional results, donor site coverage, and aesthetic results of the operation rated by the patient and surgeons were noted. The recovery of sensation at the reconstructed site was also evaluated. Results: The median follow-up was 24.8 (range, 15 to 44) months. Only one total flap loss was encountered in this study, with an overall flap survival rate of 96%. Debulking of the flap was necessitated in four patients for comfortable shoe wear; those flaps were used to cover sizeable dorsal defects of the foot. The median European Foot and Ankle Society (EFAS) daily living score at the final evaluation was 18.2 (range, 17 to 21). All patients were able to wear regular shoes without modifications. All flaps regained protective sensation, although in none of them a neurography was performed. In the Semmes-Weinstein monofilament (SWM) testing, 18 patients could feel 4.56, four patients 6.65, and three patients 4.31. The patient-rated satisfaction score for reconstruction averaged 3,7 on a five-pointscale. Conclusion: Reconstruction of forefoot soft tissue defects using the lateral arm flap provided satisfactory results in terms of successful soft tissue coverage, function, and patient satisfaction, with good cosmetic appearance and unrestricted shoe wear. Based on these findings, this flap is a good alternative for forefoot reconstruction owing to its ease of dissection, constant vascular anatomy, rich blood supply, and limited thickness. In addition, it does not sacrifice a major artery, does not limit the function of the arm, and the donor site can be closed primarily in most cases. The main disadvantage of the flap seems to be the conspicuous scar it leaves on the lateral aspect of the arm.

    2025
    引用
    AI阅读
    加入学术空间
    4Medial Plating Versus Newly Designed Intramedullary Nail with Distal Interlocking System for Distal Tibia Fractures: A Biomechanical Study with Finite Element Analysis
    Omer Kays Unal,Mirza Zafer Dagtas, Turan Najafov,Cihan Demir,Ender Ugutmen,Fuat Akpinar

    OBJECTIVES:The aim of this study was to compare the biomechanical properties of a newly designed Tibial Intramedullary Nail-Distal Supportive Bolt Locking Screw (TIN-DSBLS) and medial anatomical plate in distal tibia fracture models using finite element analysis (FEA). MATERIALS AND METHODS:Twelve medium-size, fourth-generation composite tibia models were used for testing. Models were divided into two groups as plate and nail group. A standardized osteotomy was made through each model. In the plate group, osteotomized models were fixed with distal tibia medial anatomic plate. Models in nail group were fixed with new design intramedullary nail with distal Bolt screw locking. All bone models were tested by an axial loading test machine to measure the force, maximum force, fracture site displacement and Stiffness. The second step of this study was FEA of the two models. RESULTS:The results of axial loading test results of two groups revealed that for distal tibia fracture, tibia nail which was locked with newly designed bolt screw showed superiority against plate-screw fixation about force (1597.76 ± 85.54 vs. 830.74 ± 146.7 N), maximum force (3617.6 vs. 1512.42 N), fracture site displacement (4.89 ± 1 vs. 7.85 ± 0.5 mm) and stiffness (357.88 ± 52.6 vs. 109.67 ± 13.6 N/mm). In FEA, maximum stress levels in implants were 1.7 time higher in nail group, bones were not exposed to higher levels of stress or deformation as in plate group. Maximum stress levels in bones of the nail group were 2.75 times lower than plate group. Total displacement in the plate group was more than two-fold compared to the nail group. CONCLUSION:Our study results showed that the TIN-DSBLS provides more load transfer from the nail to the cortex in tibia distal metaphyseal fractures compared to traditional nails. Taken together, it is biomechanically superior to plate-screw fixation in fractures extending up to 2.5 cm proximal to the ankle joint.

    2025
    引用
    AI阅读
    加入学术空间
    5Irreducible Metacarpophalangeal Joint Dislocations: Clinical Characteristics, Surgical Approaches, and Outcomes
    Mehmet Şah Sakçı, Ersen Türkmen,Mümin Karahan,Ekrem Özdemir

    OBJECTIVES:This study aims to evaluate the clinical characteristics, surgical management, and outcomes of irreducible metacarpophalangeal (MCP) dislocations. PATIENTS AND METHODS:Between August 2020 and August 2024, a total of 13 patients (7 males, 6 females; mean age: 29.2 ± 23.7 years; range, 7 to 78 years) with MCP dislocations who were surgically treated were retrospectively analyzed. Demographics, dislocation patterns, obstructing elements, operative approach, and postoperative complications were documented. Functional outcomes included MCP range of motion (ROM), extension lag, grip strength recovery compared to the contralateral hand, and patient-reported disability using the Quick Disabilities of the Arm, Shoulder and Hand questionnaire (QuickDASH) questionnaire. RESULTS:The index finger was most frequently involved (53.8%), with dorsal dislocations predominating (76.9%). A dorsal approach was performed in 76.9%. Dorsal reconstruction resulted in greater MCP ROM (flexion 85.8° ± 7.5° vs. 78.4° ± 6.7°), smaller extension lag (-1.8° ± 3.7° vs. -4.2° ± 5.3°), and lower disability scores (QuickDASH 4.0 ± 4.7 vs. 8.8 ± 5.5). Volar reconstruction provided superior grip strength (107.5 ± 8.7% vs. 90.9 ± 12.3%), exceeding baseline. Return-to-sport was earlier after the dorsal approach (11.5 ± 2.9 vs. 14.4 ± 3.0 weeks). Although differences did not reach statistical significance, large effect sizes (d ≥ 0.8) highlighted clinical relevance. Transient postoperative hypoesthesia occurred in two volar cases. CONCLUSION:Timely operative management, tailored to dislocation type and obstructing anatomy, is essential. The dorsal approach optimizes MCP mobility, disability reduction, and athletic recovery, whereas the volar approach enhances grip strength. These complementary outcomes underscore the importance of individualized surgical selection and structured rehabilitation.

    2025
    引用
    AI阅读
    加入学术空间
    立即登录,查看全部 938 篇论文

    高被引作者

    作者引用发文
    O. Sahap Atik147592
    Akkaya Semih25011
    Mehmet Ali Tokgoz19819
    Ahmet Guney1839
    Nuray Akkaya1817
    Mehmet Turker1818
    Mithat Oner1716
    Ataoğlu M Baybars17115
    Kemal Durak1602
    Aydın Hafız1597

    高产作者

    作者引用发文
    O. Sahap Atik147592
    Mehmet Ali Tokgoz19819
    Ulunay Kanatli14616
    Ataoğlu M Baybars17115
    Erdem Aras Sezgin12614
    Safak Gungor9914
    Baran Sarikaya14514
    Aliekber Yapar11514
    Tacettin Ayanoglu13513
    Laszlo Hangody12013

    相关期刊

    Archiv fur orthopadische und Unfall-Chirurgie
    Zeitschrift fur Orthopadie und ihre Grenzgebiete
    Acta ortopedica mexicana
    Journal of Bone and Joint Surgery, American Volume
    Revista de la Asociación Argentina de Ortopedia y Traumatologia
    International Journal of Orthopaedics Sciences
    Open Journal of Orthopedics
    Revista Chilena de Ortopedia y Traumatología
    Archives of Bone and Joint Surgery-ABJS
    Bone and Joint Open