With the proposal of carbon peak and carbon neutrality target, the tank multi-break vacuum circuit breakers with environment-friendly gas insulation is an effective methods to replace SF6 gas in the field of high voltage and ultra-high voltage. Firstly, the electric field simulation of tank multi-break vacuum circuit breakers is carried out. The scale test electrode is designed for the key position according to the electric field distribution, and the lightning breakdown test with different pressures, electrode distances and electrode structures are carried out. The results show that 0.9 MPa dry air and 0.9 MPa CO2 can satisfy the insulation configuration requirements of the tank multi-break vacuum circuit breaker. In addition, the surface flashover characteristics of the ceramic shell interface of vacuum interrupter are studied, the effects of gas pressure, metal particle attachment location on the surface flashover voltage of the ceramic shell are investigated, which provides guidance for the development of vacuum interrupters in ultra-high voltage field.
In this paper, polypropylene (PP) film samples were obtained at different stretching ratios. The dielectric properties of PP samples were studied. The crystal morphology and orientation degree of the materials were characterized. The findings indicate that the PP film sample with the stretching ratio 5 x 5 has the lowest conductivity and the highest breakdown strength. Moreover, the effect mechanism of the stretching ratio on the dielectric properties of PP films was explored. A reasonable stretching ratio can make the molecular chains of PP aligned, form an orderly crystalline morphology, and improve the crystallinity. When the stretching ratio is too high, the orientation degree of PP will decrease and the spherulite structure will be destroyed, leading to a decrease in dielectric properties. The research results can serve as a reference for improving the dielectric properties of PP films.
To address the technical challenges of DC fault clearing in DC grid, a multiport DC circuit breaker (DCCB) integrating current-limiting and fast fault clearing capabilities is proposed. Due to the topology design of the H-bridge LCSs and the additional bridge arm provided in the H-bridge component for connecting to the DC bus, the proposed DCCB possesses the capability to clear DC bus faults. Three control strategies were designed, including energization, fault interruption following current limiting and reset following current limiting. The proposed topology realizes a large reduction of peak current value by employing a current limiting component. The time required for fault clearing is minimized by implementing a bypass component. The proposed control strategy enables the pre-charge of circuit breaker capacitor by multiplexing a portion of the topology loop. The operating sequence of circuit breaker is optimized through a two-step process: preliminary fault judgment and secondary confirmation. This process further reduces the current value at the break time. A five-terminal DC grid simulation model is built in PSCAD/EMTDC, and various operating conditions of circuit breakers are simulated and verified. The results show that the proposed multiport DCCB can quickly and reliably clear faults in multiple DC lines and DC bus, reduce the peak current value, and minimize the time required for fault interruption under all working conditions.
Wind turbines often suffer from lightning strikes, iceing and other disasters. The installation of an electrothermal ice-melting device on the blade can effectively remove icing, but it will increase the risk of lightning strikes on the blade. In order to study the change of lighting attachment manner and the reliability of the existing standard lightning protection device after the blade is retrofitted with ice-melting device. This paper designs a 1:30 scaled-down rotatable 3WM ice-melting wind turbine blade for long gap lightning discharge test. Comparing the interception efficiency of the lightning receptors before and after the installation of the ice-melting device on the blade, the results show that when the lightning leader develops on the windward side of the blade, the ice-melting blade has the phenomenon of lightning receptor failure, lightning strike at the junction of the ice-melting device and the blade body. In the most serious case, the protection efficiency of the lightning receptor is only 55%. The ice-melting device ‘ shields ’ some of the lightning receptor, and the charge around the blade is distributed in an arc shape after the blade rotates, so that the ice-melting device is broken down at a lower voltage. Through the lightning strike probability model of ice-melting blade, it is found that there is a great risk of lightning at the junction of ice-melting device and blade body. The results reveal the lightning attachment manner of the ice-melting blade and further guide its lightning protection design.
The fractional level modular multilevel converter (FLMMC) can effectively improve the voltage quality of MMC with small quantities of submodules. However, the switching loss of FLMMC under existing fractional level modulation (FLM) strategy is high. In order to reduce the switching loss of FLMMC, a modified FLM strategy including submodule energy balancing segment and submodule classification inserting segment was proposed in this paper. During the energy balancing segment, both the conventional submodule and the fractional level submodule participated in sorting and inserting at the time of each level change, so as to achieve energy balance between the two types of submodules. During the classification inserting segment, the conventional submodule and the fractional level submodule were sorted and inserted separately according to the integral level or the fractional level, so as to decrease the switching times of power devices. Simulation results based on Matlab/Simulink reveal that the proposed modified FLM strategy can significantly reduce the switching loss of FLMMC, and obtain excellent effect on level multiplying.