• 学术搜索
  • 科研智能体
    • Research Labs
    • AI 阅读
    • AI 文库
    • 深度研究
    • 学者亮点
  • 学术资源
    • AI2000
    • 期刊/会议
    • 学者库
    • 学术API
      MCP&Skill
    • 溯源树
    • 数据集
  • 知识沉淀
    • 学术空间
订阅小程序
旧版功能
aminer vip
开通会员低至0.73元/天
一次搞定AI科研
立即登录
  • English
  • 联系方式
    Journal of clinical hypertension

    Journal of clinical hypertension

    JournalISSN 1524-6175eISSN 1751-7176中科院 医学 3区

    年发文量

    研究主题

    论文(5572)

    排序
    1Above‐Threshold Ambulatory Systolic Pressure and Left Ventricular Mass in Chronic Kidney Disease: Does AUC Add Beyond Mean Pressure?
    Zhen Zhang,Xinyue Dong,Xiaoqiang Ding,Wuhua Jiang,Yi Fang

    ABSTRACT Above‐threshold ambulatory systolic blood pressure (SBP) area under the curve (AUC) captures both the magnitude and duration of SBP above daytime and nighttime reference values. We examined whether this measure provided information about left ventricular mass index (LVMI) beyond daytime and nighttime mean SBP. In this cross‐sectional study, 212 Chinese adults with non‐dialysis chronic kidney disease (CKD) underwent ambulatory blood pressure monitoring and echocardiography. Daytime AUC above 135 mmHg and nighttime AUC above 120 mmHg were entered jointly. Together, daytime and nighttime AUC were significantly associated with LVMI (P < 0.001; adjusted R2 = 0.345). From the 25th to the 75th percentile, adjusted LVMI was 3.46 g/m2·7 higher for daytime AUC and 5.56 g/m2·7 higher for nighttime AUC. AUC attributable to daytime and nighttime mean SBP accounted for 89.7% of the cohort‐average above‐threshold burden. The remaining AUC not captured by those period means was not significantly associated with LVMI after adjustment for daytime and nighttime mean SBP (0.69 g/m2·7 per interquartile range; 95% confidence interval, ‐2.00 to 3.37). Above‐threshold AUC was associated with greater LVMI but added limited information beyond daytime and nighttime mean SBP in this cohort.

    2026
    引用
    AI阅读
    加入学术空间
    2Accuracy Evaluation of the Omron HEM‐7120 Automated Oscillometric Upper‐arm Home Blood Pressure Monitor in Children and Adolescents Using the AAMI/ESH/ISO 81060–2:2018 Numerical Criteria
    Tipanan Pisithkul,Kwanchai Pirojsakul

    ABSTRACT This study evaluated the Omron HEM‐7120 automated oscillometric upper‐arm home blood pressure monitor in children and adolescents against the numerical accuracy criteria of the AAMI/ESH/ISO Universal Standard. Test readings were compared with mercury auscultatory readings from two physicians using the same‐arm sequential method. Three cuffs covered arm circumferences of 12–18, 17–22, and 22–32 cm. Of 90 participants, 85 were analyzed, yielding 255 comparisons. Mean differences were −4.0 ± 5.94 mmHg for systolic and −1.8 ± 7.20 mmHg for diastolic blood pressure, meeting Criterion 1. Participant standard deviations were 5.07 and 6.48 mmHg, below Criterion 2 limits. However, the requirements regarding age, reference‐blood‐pressure and cuff distributions, reference‐measurement variability, and observer qualification were not fully met. The device met numerical criteria in this cohort, but it is not fully validated under the Universal Standard.

    2026
    引用
    AI阅读
    加入学术空间
    3Beyond Mean Blood Pressure Reduction: Distributional and Responder Effects of Bedtime Antihypertensive Dosing in Nondipping Hypertension. A Secondary Analysis of a Randomized Controlled Study
    Raymond Farah,Nicola Luigi Bragazzi,Halil Ibrahim Ceylan, Nader Ballout, Tony Hanna, Rola Khamisy‐Farah

    ABSTRACT Mean blood pressure (BP) differences do not fully characterize treatment response. We examined adjusted BP, target attainment and change distributions after morning versus bedtime antihypertensive dosing. This post hoc secondary analysis of a randomized controlled trial included 60 patients with uncontrolled hypertension and a nondipping pattern, assigned to morning or bedtime dosing (30 per group). Two‐month systolic BP (SBP), diastolic BP (DBP) and mean arterial pressure (MAP) were compared using baseline‐adjusted analysis of covariance. Secondary analyses assessed BP <140/90 mmHg and median and trimmed changes. Adjusted bedtime‐minus‐morning differences were −18.1 mmHg for SBP (95% CI −22.4 to −13.8), −11.6 mmHg for DBP (−14.5 to −8.8) and −13.9 mmHg for MAP (−16.7 to −11.0); all p < 0.001. Bootstrap intervals were similar. BP <140/90 mmHg was achieved by 29/30 (96.7%) versus 3/30 (10.0%) patients (risk ratio 9.67; 95% CI 3.30–28.34). Median SBP and DBP change differences were −9.5 and −3.0 mmHg, respectively, with confidence intervals including zero. Bedtime dosing was associated with lower adjusted two‐month BP and greater target attainment. Change‐based estimates were less precise, indicating uncertainty about the distribution of response. These exploratory findings from a small randomized trial warrant prospective confirmation.

    2026
    引用
    AI阅读
    加入学术空间
    4In Hypertensive Urgency with Volume Overload—Intravenous Loop Diuretic May Be Indicated
    Goran Koracevic,Milovan Stojanovic
    2026
    引用
    AI阅读
    加入学术空间
    5Ambulatory and Unattended, Automated Office Blood Pressure in People with and Without HIV in Tanzania: A Cohort Study of Repeatability and Regression to the Mean
    Megan Willkens,Ruth Lucinde,Cody Cichowitz,Anthony Etyang,Godfrey Kisigo,Grace Ruselu,Bernard Desderius,Lily D. Yan, Ana C. Krieger,Richard B. Devereux,Philip Ayieko,Saidi Kapiga,

    ABSTRACT Sub‐Saharan Africa (sSA) bears a high burden of hypertension and HIV, yet blood pressure measurement often relies on single‐day, conventional office readings, prone to measurement error. We assessed the short‐term repeatability of unattended, automated office BP (uAOBP) and ambulatory blood pressure monitoring (ABPM), and whether reproducibility differs by HIV status in Tanzania. We analyzed data from the Mwanza HIV&CVD cohort study, using measurements from enrollment and 1‐month later. Bland‐Altman plots visualized mean differences and limits of agreement. Reproducibility of hypertension classification was calculated using Cohen's kappa, with differences by HIV status evaluated using large‐sample variance. Of 999 participants enrolled, 750 (384 people with HIV (PWH) and 366 people without HIV (PWoH)) had valid ABPM measurements at both timepoints. The mean difference in systolic blood pressure was significant for uAOBP (−1.02 mmHg; 95% CI −1.76, −0.27) but not 24 h ABPM (−0.46; −1.02, 0.10), with similar results for diastolic blood pressure. Bland‐Altman plots showed narrower limits of agreement for ABPM. Kappa statistics were 0.45 (0.33, 0.56) for uAOBP and 0.56 (0.50, 0.62) for 24 h ABPM. Regression dilution ratios were 0.77 and 0.82 for systolic and diastolic uAOBP and 0.73 and 0.77 for ABPM. Reproducibility did not differ by HIV status. ABPM and uAOBP demonstrated high short‐term reproducibility, with ABPM showing greater stability for hypertension classification. Reproducibility did not differ by HIV status, supporting the use of both approaches in sub‐Saharan Africa.

    2026
    引用
    AI阅读
    加入学术空间
    立即登录,查看全部 5572 篇论文

    高被引作者

    作者引用发文
    Jan N. Basile938393
    Michael J Bloch806058
    Kazuomi Kario5310203
    George Bakris450968
    Jiguang Wang411988
    Marie Krousel-Wood37077
    Donald E. Morisky32853
    Barry L. Carter325226
    Michael A Weber324566
    Harry J. Ward31961

    高产作者

    作者引用发文
    Kazuomi Kario5310203
    Satoshi Hoshide275598
    Jan N. Basile938393
    Campbell Norm R C297691
    Jiguang Wang411988
    Raymond R. Townsend121085
    Thomas G. Pickering247672
    George Bakris450968
    Michael A Weber324566
    Moser Marvin94164

    相关期刊

    American journal of hypertension
    Journal of human hypertension
    Nutrition, Metabolism and Cardiovascular Diseases
    Current Hypertension Reports
    Cardiovascular diabetology
    International journal of hypertension
    High blood pressure & cardiovascular prevention : the official journal of the Italian Society of Hypertension
    European journal of preventive cardiology
    Journal of Hypertension
    Hypertension Research