• 学术搜索
  • 科研智能体
    • Research Labs
    • AI 阅读
    • AI 文库
    • 深度研究
    • 学者亮点
  • 学术资源
    • AI2000
    • 期刊/会议
    • 学者库
    • 学术API
      MCP&Skill
    • 溯源树
    • 数据集
  • 知识沉淀
    • 学术空间
订阅小程序
旧版功能
aminer vip
开通会员低至0.73元/天
一次搞定AI科研
立即登录
  • English
  • 联系方式
    Journal of Orthopedics, Traumatology and Rehabilitation

    Journal of Orthopedics, Traumatology and Rehabilitation

    JournalISSN 0975-7341eISSN 2347-3746

    年发文量

    研究主题

    论文(407)

    排序
    1Comparative Evaluation of Functional Outcome of Intraarticular Ultrasound-guided Injection of Triamcinolone Acetonide and Methylprednisolone Acetate for Primary Osteoarthritis Knee
    Kapil Dev, Amit Sehgal, Chavi Sehgal, Satish Agarwal

    Abstract Background: Osteoarthritis (OA) of the knee is one of the most prevalent degenerative joint disorders among the elderly, leading to pain, stiffness, and functional limitation. Intraarticular corticosteroid injections are frequently used for symptomatic relief. Among them, triamcinolone acetonide (TA) and methylprednisolone acetate (MPA) are two widely used depot formulations. Comparative evidence of their long-term efficacy when administered under ultrasound guidance remains limited. Materials and Methods: A prospective randomized comparative study was conducted on 200 patients with primary OA knee between May 2024 and June 2025. Patients were allocated into two groups ( n = 100 each). Group A received 40 mg MPA, and Group B received 40 mg TA via the lateral suprapatellar approach under ultrasound guidance. Pain and function were evaluated using the Visual Analog Scale (VAS) and Knee Society Score (KSS), while range of motion (ROM) was measured at baseline, 1, 3, and 6 months postinjection. Adverse effects were also documented. Results: Both corticosteroids produced significant improvement in VAS, KSS, and ROM scores over time ( P < 0.05). At 3 and 6 months, the Triamcinolone group showed superior improvement (KSS: 85.33 ± 8.07 vs. 82.64 ± 6.85; ROM: 115.1° ±9.07° vs. 112.64° ±7.22°; P < 0.05). Conclusion: Both TA and MPA are effective and safe for primary knee OA when administered under ultrasound guidance. Triamcinolone demonstrated better long-term functional outcomes and ROM, suggesting its preferable use in elderly patients with primary OA knee.

    2026
    引用
    AI阅读
    加入学术空间
    2Repurposing the Distal Medial Tibial Locking Plate for Extra-articular Distal Third Humerus Fractures with Limited Distal Fragment Purchase
    Avtar Singh, Babaji Thorat,Reddy Vamsi Krishna Arcot,Rajeev Vohra, Abhijit Das, Prabhat Mittal

    Abstract Background: Extra-articular distal-third humeral fractures present a fixation challenge: a brief distal segment limits screw purchase, while the olecranon fossa and anterior humeral curvature further constrain implant placement. Although a purpose-designed extra-articular distal humeral locking compression plate (EA-LCP) exists, it is not universally available in all trauma settings. We evaluated whether a 3.5 mm medial distal tibial locking compression plate, applied posteriorly, could reliably address these anatomical constraints. Materials and Methods: We conducted a retrospective analysis of 49 consecutive adults surgically managed for extra-articular distal-third humeral shaft fractures between January 2018 and December 2023 at a tertiary referral center. A modified posterior application of the distal medial tibial locking plate was employed in all cases. Primary endpoints were radiological union with good elbow range of motion. Minimum follow-up was 12 months. Results: The cohort comprised 29 men and 20 women (mean age 44.8 years; range 22–89). High-energy trauma accounted for 81.6% of injuries. Radiological union was confirmed in all patients at a mean of 4.44 months (range 3–6). The mean number of distal locking screws was 6.18 (range 4–9; mean plate–screw density 0.77). At final follow-up (mean 17.8 months), all patients achieved a functional flexion–extension arc exceeding 100°, with a mean Mayo Elbow Performance Score of 97 (range 85–100). No implant failure, non-union, or iatrogenic neurological injury was recorded. Conclusion: Posterior application of the 3.5 mm medial distal tibial locking plate affords dependable fixation for extra-articular distal-third humeral fractures, producing consistent union, excellent elbow function, and a low complication profile. It offers a practical, widely available alternative where a dedicated EA-LCP is not accessible.

    2026
    引用
    AI阅读
    加入学术空间
    3Using Free Tissue Transfer in Optimizing Lower Limb Amputated Stump Length
    Asif Mahamood Shaikh,Sheikh Sarfraz Ali,Mohammed Fahud Khurram

    Abstract Objective: Adequate rehabilitation of amputated lower limb requires proper prosthesis fitting in amputated stump. Preservation of adequate stump length to maximize the ability to ambulate with maximum mobility and independence is also of paramount importance. Preserving required stump length especially following guillotine amputation sometimes becomes very difficult due to lack of adequate amount of soft tissue coverage. Free tissue transfer has increasingly become salvage option. In this study, we present our experience of using muscle free flap for coverage of amputated stump to preserve adequate lower extremity limb length for the future use of prosthesis and for a faster return to physical activity. Materials and Methods: In this retrospective study, we evaluated the medical records of five patients whose lower limb amputated stumps were reconstructed with free tissue transfer between June2022 and June 2023. Key parameters assessed included flap success rates, complications, functional outcomes, and patient satisfaction. Results: Two cases of below knee amputation and one case of choupart amputation were reconstructed with free gracilis muscle flap. Two cases of Lisfranc amputations were reconstructed with latissimus dorsi muscle flap. Data analysis reveals a favourable flap success rate with no flap related complications. Functional outcomes demonstrated better prosthesis fitting and weight-bearing capacity and adequate range of motion. Patient satisfaction scores were consistently high, indicating improved body image and quality of life post surgery. Conclusion: Use of a free flap to reconstruct amputated stump provides stable coverage, preserves adequate stump length, and results in good functional outcomes.

    2026
    引用
    AI阅读
    加入学术空间
    4A Retrospective Comparison of Outcomes Between Patients Undergoing Urgent Versus Nonurgent below Knee Amputations in the Setting of Trauma Versus Chronic Disease
    Timothy Hartman, Benjamin C. Graham, Janet Nguyen, Conor Lynch, Sachin Gandhi, Zachary L. Telgheder, Matthew P. Sullivan

    Abstract Aims: The purpose of this study was to examine the outcomes of below knee amputations (BKAs) performed urgently (≤30 days following injury) versus nonurgently (>30 days following injury/onset). Settings and Design: Patients who underwent BKA by an orthopedic trauma surgeon at a single Level One trauma center between December 2012 and November 2021 were retrospectively queried. Materials and Methods: Patients were stratified by urgent versus nonurgent cases (≤ or >30 days after initial injury/problem onset). Baseline characteristics and postoperative complications were compared using inferential statistics. Binomial logistic regression analysis was used to model odds of complications based on operative timing and demographic characteristics. Results: One hundred and thirty patients were included, with 71 patients undergoing urgent BKA and 59 patients undergoing nonurgent BKA. Estimated blood loss was greater for urgent amputations ( P = 0.013). No significant predictors of postoperative complications were identified. Urgent amputation was independently associated with increased odds of returning to the operating room (RTOR) ( P = 0.043). Conclusions: Patients undergoing urgent BKA may be at increased risk for higher blood loss and RTOR rates compared to patients undergoing BKA due to chronic conditions or subacute injury. These findings may guide surgeons in setting appropriate expectations for patients who require urgent BKA after traumatic injury. Limitations: All BKAs were performed by orthopedic surgeons at a single institution. In addition, we do not identify a definitive explanation regarding differences in outcomes between urgent and nonurgent BKAs. The retrospective nature of our study makes it difficult to offer recommendations related to the timing of BKAs.

    2026
    引用
    AI阅读
    加入学术空间
    5Functional Outcomes of Proximal Tibia Fractures Treated with Proximal Tibial Compression Plates: A Prospective Observational Study of 100 Cases
    Amrit Prakash Singh, Amit Sehgal, Satish Agarwal, Farzan Khan, Yogesh Pandey

    Abstract Context: Proximal tibial fractures are common intra-articular injuries of the weight-bearing knee whose optimal fixation, particularly the choice between single lateral and dual plating, remains debated. Aims: To evaluate the functional and radiological outcomes of Schatzker type I–VI proximal tibial fractures fixed with proximal tibial compression plates, and to compare single lateral plating with dual plating. Settings and Design: Prospective observational study at a tertiary care teaching hospital over 1 year. Subjects and Methods: One hundred adults with Schatzker I–VI fractures were treated with a single lateral locking compression plate in 57 (57.0%) or dual plates in 43 (43.0%) according to fracture morphology. The Knee Society Score (KSS), modified Rasmussen functional score, knee range of motion, and radiological union were assessed at 6 and 9 months. Statistical Analysis Used: Paired t -test, independent-samples t -test/Mann–Whitney U and Fisher’s exact test; P < 0.05 was significant. Results: Mean age was 36.5 ± 11.3 years with a male preponderance of 83 (83.0%); road traffic accidents caused 84 (84.0%) injuries. Mean radiological union was 19.6 ± 1.5 weeks with no nonunion. Complications occurred in 31 (31.0%) patients, most commonly infection 17 (17.0%). Mean KSS improved from 82.2 ± 5.9 at 6 months to 83.3 ± 5.9 at 9 months ( t = 2.19, P = 0.031); at 9 months, 83 (83.0%) were excellent. Single and dual plating showed comparable KSS (82.9 ± 6.2 vs. 83.9 ± 5.7; P = 0.377), union ( P = 0.397), and complication rates 17 (29.8%) vs. 14 (32.6%); P = 0.83. Conclusions: Compression plating restored articular congruity with reliable union and good knee function. Single lateral plating for simple/lateral patterns and dual plating for bicondylar patterns gave comparable functional outcomes when fixation was matched to fracture morphology.

    2026
    引用
    AI阅读
    加入学术空间
    立即登录,查看全部 407 篇论文

    高被引作者

    作者引用发文
    Agrawal Alok C15737
    Manisha Ruikar1531
    Harshal Sakale13111
    Bikas Sahoo1103
    Ajit Singh1101
    Sahu Ramji Lal314
    Rajesh Rajesh Kapilakapila291
    Rakesh Sharma291
    Mahesh Goyal291
    Ankush Chugh291

    高产作者

    作者引用发文
    Agrawal Alok C15737
    Harshal Sakale13111
    Sanjay Keshkar68
    Wai Wang Chau88
    Bobby Kin Wah Ng88
    Shiv Bhagwan Sharma58
    Ajai Singh157
    Chandra Prakash Pal97
    Purushottam Jhanwar95
    Bikram Keshari Kar25

    相关期刊

    暂无数据
    暂无数据