
For many users of the neutron and X-ray reflectometry instruments at NIST, these measurements represent a relatively small and specialized part of their research portfolio. As such, providing calculation and modeling tools that are as accessible and easy-to-use as possible is a high priority of the facility. In order to meet this need, a purely web-browser-based calculator for reflectivity modeling and rudimentary fitting has been developed and provided on a publicly accessible web server.Going to https://www.ncnr.nist.gov/instruments/magik/calculators/reflectivity-calculator.html, will load a one-page web application into the browser. Any relatively modern browser with support for ECMAScript 5 will be able to load and run the application. A calculator for magnetic samples can be found at https://www.ncnr.nist.gov/instruments/magik/calculators/magnetic-reflectivity-calculator.html.
Comparative modeling of protein structure is a process which determines the three-dimensional structure of protein molecules on the basis of amino acid sequence similarity to experimentally linown structures. The procedure is facilitated by the growing database of protein structures obtained from crystallography. In this review a series of stages in the modeling process are identified and discussed. These are: (i) obtaining a reliable amino acid sequence of the structure of interest, (ii) producing a structurally correct sequence alignment, (iii) identifying which structural features are conserved between target and parent structures, (iv) modeling the new pieces of structure, and (v) tests of reliability.
A supercritical fluid chromatograph has been designed and constructed to make physicochemical measurements, while retaining the capability to perform chemical analysis. The physicochemical measurements include diffusion coefficients, capacity ratios, partition coefficients, partial molar volumes, virial coefficients, solubilities, and molecular weight distributions of polymers. In this paper, the apparatus will be described in detail, with particular attention given to its unique features and capabilities. The instrument has recently been applied to the measurement of diffusion coefficients of toluene in supercritical carbon dioxide at a temperature of 313 K, and pressures from 133 to 304 bar (13.3-30.4 MPa). The data are discussed and compared with previous measurements on similar systems.
The resistance of metals is a function of applied pressure, and this dependence is large enough to be significant in the calibration of transient hot-wire thermal conductivity instruments. We recommend that for the highest possible accuracy, the instrument's hot wires should be calibrated in situ. If this is not possible, we recommend that a value of γ, the relative resistance change with pressure, of -2×10-5 MPa-1 be used to account for the pressure dependence of the platinum wire's resistance.