
Abstract Activation of ions inside a mass spectrometer to induce dissociation or conformational changes can be a powerful way to investigate their structure. Although the most common way to activate ions in contemporary instruments is by collisions with a neutral buffer gas, ions also constantly exchange photons with the ambient radiation field of the instrument. In blackbody infrared radiative dissociation (BIRD) experiments performed in Fourier-transform ion cyclotron resonance or ion trap instruments at low pressure, radiative energy exchange alone can be sufficient to dissociate or unfold ions on the upper-millisecond to several-minute timescale, depending on the thermochemical barrier and radiation temperature. Collisional activation, as implemented in most commercial platforms, typically occurs on the microsecond- to few-millisecond timescale, a roughly thousandfold shorter kinetic window than in BIRD experiments. Radiative energy exchange effects on collisional heating and cooling for large biomolecular ions in these experiments are poorly understood, and computing radiative energy exchange rates for ions >∼1 MDa has been intractable due to the enormous density of states of these ions. Here, we introduce an algorithm for computing radiative energy exchange rates for large ions as a function of ion mass, composition, and initial vibrational temperature. Scaling of radiative emission rates with ion size and vibrational temperature, and the competition between radiative cooling and collisional heating, are studied by incorporating results from this algorithm into the IonSPA software. Implications for thermochemical CID/CIU barrier determination for large ions and practical limitations for collisional heating of multi-MDa- to GDa-sized ions in charge detection mass spectrometry are also discussed.
Abstract Synthetic peptide therapeutics exhibit highly heterogeneous impurity profiles containing numerous structural and sequence-related species that require stringent analytical control to ensure safety, efficacy, and manufacturing consistency. Conventional UV-based release methods and two-tier LC-UV/LC-MS workflows suffer from coelution ambiguities and cross-method inconsistencies, complicating impurity identification and quantitation. The multi-attribute method (MAM) comprises amino-acid-level impurity characterization, targeted quantitation of product quality attributes, and new peak detection (NPD) as a differential analysis against a reference standard to detect the presence, absence, or change in abundance of any species. Here, we present a multi-attribute method (MAM)-based approach specifically for synthetic peptide impurity monitoring, combining both targeted quantitation of specified impurities and new peak detection (NPD) for unspecified impurities within a single LC-MS workflow that was developed and validated for GMP release testing for a synthetic therapeutic peptide. The MAM workflow leveraged extracted ion chromatograms for specified impurity assignment and quantitation, while non-targeted MS processing enabled NPD-based detection of unspecified impurities exceeding method reporting thresholds. Development mode validation demonstrated satisfactory analytical performance across sensitivity, accuracy, precision, and specificity. Key technical considerations overcome in this workflow include reliable LC-MS discrimination of near-isobaric impurities and optimization of charge-state and isotope peak selection. By consolidating targeted and non-targeted impurity monitoring into a single workflow, this approach eliminates the cross-method inconsistencies inherent to conventional two-tier methods while improving analytical efficiency and specificity through orthogonal retention time and accurate mass discrimination. The workflow was demonstrated on a single synthetic peptide drug substance, with potential applicability to other synthetic modalities yet to be evaluated.
Abstract Proteoform imaging mass spectrometry (PiMS) using nano-DESI MS enables label-free detection of thousands of intact proteoforms from biological tissue sections and single cells. However, proteome coverage using this approach is limited by the liquid extraction process at the solvent–tissue interface. Here, we demonstrate a simple approach using tailored primary capillary probe size and geometry to enhance proteoform detection. Intriguingly, we found that the enhancement factor strongly depends on the molecular weight and subcellular localization of the proteoforms. We rationalized these observations by dissecting the theory of interfacial fluid dynamics within the nano-DESI liquid bridge. These principles were further leveraged to achieve proteoform detection in surface-immobilized single cells with enhanced sensitivity and throughput.
Abstract Two-dimensional correlation mass spectrometry (2D-CMS) is a cross-correlation-based technique that can be used to identify mass-spectral signals that arise from a common molecular origin. In this study, 2D-CMS is explored for mixtures of the blood-pressure medications atenolol and metoprolol with the specific aims of precursor/fragment-ion identification and deconvolution of unresolved spectral peaks. Atenolol and metoprolol are structurally similar and produce several identical or isobaric fragment ions. In addition, the first isotopic peak of the atenolol ion (i.e., [MH++1]) at m/z 268.1737 and the protonated metoprolol ion at m/z 268.1834 produce an isobaric overlap for the mass-spectral resolving power used in this study (m/Δm = 17,500 at m/z 200). These phenomena result in numerous peaks that originate from both analytes, complicating the interpretation of mass-spectral results for precursor/fragment identification and assignment of overlapped peaks. Semiquantitative information extracted from 2D-CMS results enabled the determination of the relative contribution of each analyte to the total signal of their shared fragments. In addition, narrow m/z regions within unresolved mass-spectral peaks could be attributed to their specific molecular origin. For a series of solutions with varying proportions of each analyte, metrics derived from 2D-CMS were found to scale with the relative concentration of each analyte. Calibration results obtained from 2D-CMS were comparable to those obtained from traditional peak-fitting methods but provided additional information that enabled peak identification. These results show the utility of 2D-CMS for deconvolution of mass spectra acquired without separation or isolation of analytes or at low resolving powers.
Abstract To address the technical need for the precise detection and semiquantitative analysis of coal-derived particulate matter in complex soil matrices, this study optimized and established a comprehensive detection method based on time-of-flight secondary ion mass spectrometry (ToF-SIMS) and developed a semiquantitative analysis strategy utilizing AI-assisted single-particle size-resolved image recognition. Through systematic optimization of experimental conditions, it was determined that C4H3– is the characteristic ion of coal-derived particles, while Na+ and Ca+ are the characteristic ions of noncoal-derived (soil mineral) particles. Ethanol-dispersed monocrystalline silicon wafers were selected as the optimal substrate, and Bi3+ as the ion source. Since bright spots characteristic of coal-derived particles could not be characterized on secondary ion images under positive ion conditions but could be detected in negative ion mode, the negative ion mode was adopted as the testing condition for time-of-flight secondary ion mass spectrometry (ToF-SIMS). Through multiple rounds of human-machine interaction, parameters for the AI-assisted counting method were established. This method was applied to the analysis of soil samples from 10 typical sampling sites in the Tongting mining area, and the results for coal-derived particulate matter were validated against the gold standard GC-MS. The detection method and semiquantitative strategy established in this study provide a feasible technical pathway for the efficient and accurate detection and characterization of coal-derived particulate matter in complex matrices, holding significant practical value.