Background Optical nanoscopy based on separation of single molecules by stochastic switching and subsequent localization allows surpassing the diffraction limit of light. The growing pursuit towards live-cell imaging using nanoscopy demands advancements in both science and technology. Results In this article, we provide an overview of the technological advancements in the development of scientific cameras used for nanoscopy. We discuss the prospects of novel digital photon counting cameras based on a single-photon avalanche diode (SPAD) array camera for optical nanoscopy. Numerical simulations are used to evaluate and compare different scientific cameras for their performance towards single-molecule identification and localization. Conclusion A SPAD array camera with single-photon sensitivity and zero read-out noise allows for the detection of extremely weak signals at ultra-fast imaging speeds. With temporal resolution in the order of micro-seconds, a SPAD array camera offers great potential for live-cell imaging with super-resolution.
The dimensions of neuronal synapses suggest that optical super-resolution imaging methods are necessary for thorough investigation of protein distributions and interactions. Nanoscopic evaluation of neuronal samples has presented practical hurdles, but advancing methods are making synaptic protein topology and quantification measurements feasible. This work explores the application of Photoactivated Localization Microscopy (PALM) pointilistic super-resolution imaging for investigation of the membrane bound sodium pump, the Na,K-ATPase, in matured neurons. Two isoforms of the sodium pump (ATP1a1 and ATP1a3) were studied in cultured neurons using the PALM-compatible fluorescent proteins PAGFP and mEos. Nanoscopic imaging reveals a compartmentalized distribution of sodium pumps in dendritic spines. Several nanoclusters of pumps are typically found in the spine head and relatively few in the spine neck. The density of sodium pumps was estimated from a quantification of detected single molecules to 600-800 pump copies/um2 in the spine heads. We have utilized PALM for dissection of nanoscale localization in mature cultured neurons and demonstrated similar topology and quantification estimates with PAGFP and mEos. PALM topology assessments of the sodium pump appeared similar to previous STED studies, though quantification estimates varied notably, implying that sample labeling strategies and choice of nanoscopic imaging method are critical factors for correct quantification.
Multi-color super-resolution (SR) imaging microscopy techniques can resolve ultrastructural relationships between- and provide co-localization information of- different proteins inside the cell or even within organelles at a higher resolution than afforded by conventional diffraction-limited imaging. While still very challenging, important SR colocalization results have been reported in recent years using STED, PALM and STORM techniques.
To enhance the resolution of a confocal laser scanning microscope the additional information of a pinhole plane image taken at every excitation scan position can be used (Sheppard 1988). This photon reassignment principle is based on the fact that the most probable position of an emitter is at half way between the nominal focus of the excitation laser and the position corresponding to the (off centre) detection position. Therefore, by reassigning the detected photons to this place, an image with enhanced detection efficiency and resolution is obtained. Here we present optical photon reassignment microscopy (OPRA) which realizes this concept in an all-optical way obviating the need for image-processing. With the help of an additional intermediate optical beam expansion between descanning and a further rescanning of the detected light, an image with the advantages of photon reassignment can be acquired. However, just as in computational photon reassignment, a loss in confocal sectioning performance is caused by working with relatively open pinholes. The OPRA system shares properties such as flexibility and ease of use with a confocal laser scanning microscope, and is therefore expected to be of use for future biomedical routine research.
BACKGROUND:Super-resolution microscopy techniques are often extremely susceptible to sample drift due to their high spatial resolution and the long time needed for data acquisition. While several techniques for stabilizing against drift exist, many require complicated additional hardware or intrusive sample preparations. We introduce a method that requires no additional sample preparation, is simple to implement and simultaneously corrects for x, y and z drift.RESULTS:We use bright-field images of the specimen itself to calculate drift in all three dimensions: x, y and z. Bright-field images are acquired on an inexpensive CCD. By correlating each acquired bright-field image with an in-focus and two out-of-focus reference images we determine and actively correct for drift at rates of a few Hertz. This method can maintain stability to within 10 nm for x and y and 20 nm for z over several minutes.CONCLUSION:Our active drift stabilization system is capable of simultaneously compensating x, y and z drift through an image-based correlation method that requires no special sample treatment or extensive microscope modifications. While other techniques may provide better stability, especially for higher frequency drift, our method is easy to implement and widely applicable in terms of both sample type and microscopy technique.