PURPOSE To evaluate Geant4-DNA for the simulation of radiochemical yields in liquid water up to 1µs after irradiation, for incident electrons, protons and alpha particles beams in the keV-MeV kinetic energy range. METHODS Simulations of radiochemical yields are presented as a function of time for electrons and as a function of the beam parameter MZ2/E for protons and alpha particles. They use the "chem6" and "UHDR" reference examples available in Geant4 version 11.4.0 (December 2025). The impact of physics, chemistry and time step models is investigated, and quantitatively compared to experimental data. RESULTS The option 4 physics constructor shows better plausibility for the simulation of G-values versus time and G-values versus MZ2/E. The option 3 chemistry constructor shows a global better agreement with experimental data. The micro/mesoscopic "UHDR" example is able to reproduce "chem6" results for simulations up to 1µs. CONCLUSION It remains difficult to clearly favor one physics or chemistry model over another because of the dispersion of experimental radiolysis data at short times. We recommend continuing experimental radiolysis measurements to help benchmark simulations.
Purpose The Global Noise Level (GNL) is an established objective CT noise metric evaluated directly on patient clinical images. A free, open-source, customisable tool to acceptance-test and validate commercial GNL software applications, monitor patient image noise, optimise protocols and which permits flexible input parameters for research purposes is lacking. This working developed such a tool and investigated the impact of various user-supplied input parameters on the GNL. Method The tool was developed in Python and followed standard published methods; it was validated against manual calculation. The impact of user-supplied input parameters on GNL values, namely the upper/lower CT-number threshold-fences, kernel size and shape (square and novel disc-shape) and histogram bin-widths, was studied by applying the tool to two abdomino-pelvic multi-centric, multi-system and multi-phasic image datasets (n = 357). Results The tool accurately calculated GNL (Bland-Altman plot of automatic vs manual calculation showed bias = 0 and standard deviation = 0) with a processing rate of 14 slices/s. GNL values changed significantly as a function of threshold-fence. GNL values increased monotonically with kernel size for both square and disc kernels with the latter consistently giving lower values. GNL values also increased with bin-width. Conclusions A free, fully-automated flexible tool for GNL calculation for adult abdomino-pelvic CT was developed. Since GNL values are dependent on choice of input parameters, these should therefore be reported alongside GNL values. Recommended parameters are threshold fences of − 300:0HU for adipose and 0:170HU for soft tissue (higher when contrast is present), 3 mm radius disc-kernel, 1.0HU bin-width.
BACKGROUND Intensity-modulated proton therapy (IMPT) has shown promise in reducing toxicityfor patients with oropharyngeal squamous cell carcinoma (OPSCC), while maintaining comparable tumor control to intensity-modulated radiation therapy (IMRT). However, technical, logistical and economic factors have limited widespread implementation. METHODS We conducted the first Italian multicenter in-silico comparative study of photon and proton plans in 100 patients with HPV-related OPSCC, involving seven radiation oncology departments. Clinical photon-based plans (mostly using Volumetric Modulated Arc Therapy (VMAT)) were compared with robustly optimized IMPT plans generated using the CNAO beamline. Dosimetric endpoints and normal tissue complication probability (NTCP) values for xerostomia and dysphagia were assessed. Eligibility for IMPT was retrospectively estimated using the Dutch model-based selection (MBS)criteria. RESULTS Target coverage was comparable between modalities, although IMPT plans showed slightly lower conformity indices. IMPT significantly reduced the dose bath to healthy tissues, with lower mean doses to the parotids, submandibular glands, pharyngeal constrictors, oral cavity, brainstem, and spinal cord (p < 0.01). NTCP analyses predicted clinically relevant reductions in xerostomia and dysphagia with IMPT. Applying the MBS approach, 36 % of patients were deemed eligible for PT, consistent with previous reports. Inter-center variability in eligibility reflected differences in delineation practices and clinical protocols. CONCLUSIONS This study tested the feasibility of a multicenter model-based evaluation for IMPT in Italy. A substantial proportion of OPSCC patients could benefit from IMPT, though results likely represent a conservative estimate due to protocol choices. Standardized delineation, robust optimization, and integration of NTCP models are essential for consistent patient selection.