• 学术搜索
  • 科研智能体
    • Research Labs
    • AI 阅读
    • AI 文库
    • 深度研究
    • 学者亮点
  • 学术资源
    • AI2000
    • 期刊/会议
    • 学者库
    • 学术API
      MCP&Skill
    • 溯源树
    • 数据集
  • 知识沉淀
    • 学术空间
订阅小程序
旧版功能
aminer vip
开通会员低至0.73元/天
一次搞定AI科研
立即登录
  • English
  • 联系方式
    Physics and imaging in radiation oncology

    Physics and imaging in radiation oncology

    JournalISSN 2405-6316eISSN 2405-6316中科院 医学 2区

    年发文量

    研究主题

    论文(1143)

    排序
    1Comparative Evaluation of Plan Robustness in Proton and Photon Radiotherapy in Deep Inspiration Breath-Hold for Mediastinal Lymphomas Throughout the Treatment Course
    Filip Hörberger,Marika Enmark,Karin M. Andersson, Rebecka Ericsson Szecsenyi,Gracinda Johansson,Daniel Molin,Kenneth Wikström,Ingrid Kristensen,Anna Flejmer,Anneli Edvardsson

    Background and purpose Proton therapy (PT) is sensitive to anatomical changes and setup uncertainties, which can compromise dose robustness in the treatment of mediastinal lymphoma, an issue less pronounced with photon-based radiotherapy. Variations in target position and size can potentially influence plan robustness. This study evaluated the robustness of pencil beam scanning (PBS) PT versus volumetric modulated arc therapy (VMAT) photon treatment plans across sub-target volumes and organs of interest (OOI) in deep inspiration breath-hold (DIBH) throughout treatment. Material and methods Twenty-eight patients with upper mediastinal lymphoma treated with PBS-PT in DIBH were included. Clinically delivered PBS-PT plans were retrospectively compared with VMAT plans optimized per institutional standard-of-care. All plans were recalculated on weekly verification computed tomography images (vCTs) to assess target coverage and OOI doses. The internal target volumes (ITV) were subdivided into mediastinum, fossa supraclavicularis, neck, axilla and, along with OOIs, transferred from planning CTs to the vCTs. Results In the nominal plans, PBS-PT generally achieved lower OOI doses than VMAT, an advantage maintained on the vCTs. Both modalities demonstrated robust target coverage and OOI sparing. ITVTotal coverage fell below the set criterion (D98% > 95%) on at least one vCT for six patients with PBS-PT, but only one patient for VMAT. Pronounced deviations (D98% < 90%) occurred for two PBS-PT cases. Sub-target robustness was generally good. Conclusions Both PBS-PT and VMAT were robust for mediastinal lymphoma treatment in DIBH. In a proton-eligible DIBH cohort, PBS-PT provided superior OOI sparing, while VMAT demonstrated greater consistency in target coverage.

    2026
    引用
    AI阅读
    加入学术空间
    2Linear Energy Transfer Optimization Mitigates Biological Model Discrepancies in Carbon Ion Radiotherapy for Pelvic Osteosarcoma
    Natalia Sycheva, Katharina Kozyra,Katharina Seidensaal, Hanna Waldsperger,Semi B. Harrabi,Jürgen Debus,Andrea Mairani,Thomas Tessonnier

    Background and purpose In the combined treatment of osteosarcoma with a carbon ion radiotherapy (CIRT) boost, large pelvic tumors are associated with significantly lower tumor control compared to craniofacial localization. This could be linked to lower dose-averaged linear energy transfer (LETd) values in the target and larger uncertainties related to the model used for relative biological effectiveness (RBE) calculation. This study aimed to bridge the difference between RBE-weighted doses from two clinically used models, the local effect model I (LEM-I) and the modified microdosimetric kinetic model (mMKM), using LETd optimization. Materials and methods Fifteen pelvic osteosarcoma CIRT plans, initially optimized with LEM-I, were re-optimized to achieve higher target LETd while preserving target and organ at risk (OAR) dose objectives. Both dose- and LET-optimized plans were recalculated with mMKM, and dose metrics were compared across the groups. Robustness against setup and range uncertainties and changes in patient anatomy (using control CTs) was investigated. Results LETd optimization resulted in target LETd escalation without compromising LEM-I target coverage. The LET-optimized group also demonstrated better mMKM dose coverage and a significant decrease (up to 9% of prescription) in the disparity between LEM-I and mMKM target dose. OAR doses remained largely unaffected by model choice or optimization strategy. The robustness loss with LETd optimization was minor (intra-patient dose variability increased by 0.3–2.3%) compared to the reduction in model-to-model variation. Conclusions When adequately balanced with physical uncertainties, LETd optimization could become a useful strategy for bridging RBE model predictions and increasing the efficacy of CIRT.

    2026
    引用
    AI阅读
    加入学术空间
    3Radiomics of Mandibular Osteoradionecrosis with Recurrence: the Need for Etiologic and Temporal Validation
    Arnaud Beddok

    Ozcan and colleagues present an exploratory radiomic analysis of 24 surgically treated patients with pathologically confirmed mandibular osteoradionecrosis (ORN), including three with associated recurrence (Ozcan et al., 2026 [1]). While the clinical question is important, the validity of the underlying reference standard requires careful scrutiny before interpreting radiomic differences as indicators of recurrence within ORN.

    2026
    引用
    AI阅读
    加入学术空间
    4Manual Brush Vs Artificial Intelligence Pencil: Evaluating Tools for Auto-Contour Refinement of Head-and-neck Tumors on Positron Emission Tomography and Computed Tomography Scans
    Prerak Mody,Nicolas Chaves de Plaza,Mark Gooding, Martin de Jong,Mischa de Ridder, Niels den Haan, Jos Elbers,Klaus Hildebrandt,Marius Staring
    2026
    引用
    AI阅读
    加入学术空间
    5Six-year Data from Three Magnetic Resonance-Guided Radiotherapy Systems Demonstrate Long-Term Stability of Linear Accelerator Quality Assurance
    Guido C. Hilgers,Simon J. Woodings, Thomas A. Foppen,Jochem W.H. Wolthaus, André W. Minken,Bas W. Raaymakers,Bram van Asselen

    Background and Purpose Magnetic resonance-guided radiotherapy systems require comprehensive quality assurance (QA) programs to ensure safe and precise treatment delivery. This study evaluates the long-term behavior and variability of linac-related QA results across three clinically operated 1.5 T MRI-linacs at a single institution and assesses compliance with tolerance limits. Materials and Methods QA data acquired over a six-year period from three clinically operated 1.5 T MRI-linacs were retrospectively analyzed. A range of linac-related dosimetric and mechanical QA tests was included. Performance envelopes (mean ± 2 SD) were constructed to characterize variability relative to tolerance limits. Results For 11 of 13 QA tests, performance envelopes for the associated metrics remained within the applied tolerance limits. For the two remaining tests, envelopes slightly extended beyond these limits. These deviations were not considered clinically relevant, and their underlying causes were understood. No progressive trends of clinical relevance were observed in the linac-specific time series. Conclusions Stability of linac-related QA results was demonstrated over six years across three MRI-linacs, supporting reconsideration of the QA program.

    2026
    引用
    AI阅读
    加入学术空间
    立即登录,查看全部 1143 篇论文

    高被引作者

    作者引用发文
    Wouter Van Elmpt47716
    Ludvig Muren42838
    Frank Verhaegen37913
    Mark J Gooding3257
    Tyagi Neelam32012
    Miguel A Palacios2866
    V. Taasti28216
    Bas Raaymakers27723
    Nuria Jornet26810
    Richard Canters2679

    高产作者

    作者引用发文
    Ludvig Muren42838
    Daniela Thorwarth18224
    Bas Raaymakers27723
    Stephanie Tanadini-Lang11023
    Matthias Guckenberger11621
    Janssen Tomas17418
    Nicolaus Andratschke13417
    Wouter Van Elmpt47716
    V. Taasti28216
    Jan-Jakob Sonke13216

    相关期刊

    Medical dosimetry : official journal of the American Association of Medical Dosimetrists
    Journal of applied clinical medical physics
    Igaku butsuri : Nihon Igaku Butsuri Gakkai kikanshi = Japanese journal of medical physics : an official journal of Japan Society of Medical Physics
    Nihon Hoshasen Gijutsu Gakkai zasshi
    Journal of medical physics
    Radiological Physics and Technology
    European journal of hybrid imaging
    EJNMMI Physics
    PHYSICS & IMAGinG in RADIATION ONCOLOGY
    Physica Medica-European Journal of Medical Physics