• 学术搜索
  • 科研智能体
    • Research Labs
    • AI 阅读
    • AI 文库
    • 深度研究
    • 学者亮点
  • 学术资源
    • AI2000
    • 期刊/会议
    • 学者库
    • 学术API
      MCP&Skill
    • 溯源树
    • 数据集
  • 知识沉淀
    • 学术空间
订阅小程序
旧版功能
aminer vip
开通会员低至0.73元/天
一次搞定AI科研
立即登录
  • English
  • 联系方式
    Regional Anesthesia and Pain Medicine

    Regional Anesthesia and Pain Medicine

    JournalISSN 1098-7339eISSN 1532-8651中科院 医学 2区

    年发文量

    研究主题

    论文(9485)

    排序
    1Five-in-two (FIT) Ankle Block and Earlier Ultrasound-Guided Boot Block
    Lucas Deffontis,Matthias Herteleer,Olivier Choquet,Xavier Capdevila
    2026
    引用
    AI阅读
    加入学术空间
    2Distinguishing Uncertainty from Ineffectiveness in Peripheral Nerve Corticosteroid Recommendations
    Mia A. Ramos, Fiorela Martinez,Eva Kubrova,Robert Pagan Rosado,Jason Eldrige
    2026
    引用
    AI阅读
    加入学术空间
    3Reporting of Commercial Involvement and the Direction of Stated Conclusions in the Neuromodulation-for-pain Literature: a Meta-Research Study of 896 Publications
    Pablo E Rueda Juan, Felipe Hernandez Zaballos,David Abejon Gonzalez
    2026
    引用
    AI阅读
    加入学术空间
    4Asymptomatic Intrathecal Baclofen Pump Catheter Failure Discovered During Routine Reservoir Replacement: a Case Report
    Heeho Kim,Priyanka Singla

    Background Intrathecal baclofen (ITB) therapy effectively manages severe spasticity. While mechanical complications typically cause therapy loss or withdrawal, structural disruptions can remain completely occult due to anatomical adaptations. This report explores the unique management of an incidentally discovered catheter transection during routine reservoir exchange.Case presentation A female patient in her 30s with cerebral palsy had been treated with ITB since 2011 without functional complaint, despite sluggish cerebrospinal fluid (CSF) flow noted at a 2019 pump exchange that did not prompt catheter revision. After relocating out of state, the patient returned in 2025 for a planned pump reservoir replacement, reporting no interval decline. Preoperative catheter port myelography was not successful due to failure of CSF aspiration from the catheter access port, and intraoperative exploration revealed the catheter was completely fractured at its fascial insertion point, despite the reported years of clinical stability. Fragment retrieval required partial laminectomy and multilayer dural repair; after new hardware placement and retitration, her therapeutic outcome improved dramatically.Conclusions Subjective clinical efficacy is an unreliable proxy for system patency. Aging hardware configurations require proactive radiographic monitoring and targeted surgical revision to minimize the risk of withdrawal.

    2026
    引用
    AI阅读
    加入学术空间
    5Interpreting the Limits of Non-Human Teaching Systems from Small Data Sets
    Habib Md Reazaul Karim, Brian O’Brien
    2026
    引用
    AI阅读
    加入学术空间
    立即登录,查看全部 9485 篇论文

    高被引作者

    作者引用发文
    Joseph M. Neal7721125
    Richard Brull567284
    Ki Jinn Chin544454
    Vincent W S Chan522578
    Terese T. Horlocker501649
    Denise J. Wedel447826
    Richard Rosenquist412127
    Admir Hadzic388270
    F. Kayser Enneking371536
    Michael J Barrington371044

    高产作者

    作者引用发文
    Joseph M. Neal7721125
    Brian M. Ilfeld336194
    Richard Brull567284
    Edward R. Mariano223780
    Stavros G. Memtsoudis259980
    De Quang Hoei Tran252479
    Vincent W S Chan522578
    Philip Peng340470
    Admir Hadzic388270
    Samer Narouze278068

    相关期刊

    Journal of Clinical Anesthesia
    Current Pain and Headache Reports
    Pain physician
    Korean journal of anesthesiology
    Pain and therapy
    Pain Practice
    Current Opinion in Anaesthesiology
    Local and Regional Anesthesia
    European Journal of Anaesthesiology
    Anesthesiology