Previous studies of Vermont granite workers averred that pulmonary function loss was occurring at 2 to 3 times the normal rate. The excess loss was attributed to the current, relatively low concentrations of dust prevailing in the stone sheds. Because the Vermont State Health Department had traditionally provided surveillance of granite workers to detect evidence of occupationally related illness, we offered pulmonary function screening to any currently employed worker. Spirometric data from the first 150 workers, compared with data from the previous studies, showed a large increase in the FVC and a smaller increase in the FEV1. We therefore undertook a survey of the entire stone shed work force, as well as of retired workers tested previously. The results in 487 current workers indicated an overall increase in FVC from 1974 to 1979 of 0.540 L, and an increase in FEV1 of 0.030 L; predicted losses based on the previous studies were 0.350 to 0.400 L in FVC and 0.250 to 0.350 L in the FEV1. Analysis of data ...
The complex function of respiratory tract cilia implies highly organized control. Serotonin has been identified as an endogenous pacemaker substance in the lateral cilia of the lamellibranch (Mytilus edulis) gill. In this study, the effect of serotonin and related compounds on mucus flow in cat trachea was measured. Serotonin by aerosol increased mucus flow significantly, and a similar effect was found with 5-hydroxytryptophan and 5-hydroxyindole acetic acid. These results indicate that the cilioactive principle depends on the hydroxyl group. Low, ineffective concentrations of serotonin were made cilioactive when administered with calcium. This effect is similar to the close relationship of calcium to the action of serotonin on muscle. Despite the cilio-acceleratory effects of this group of compounds, no pacemaker has been identified in the ciliary systems of higher animals.
The objective of this study was to determine whether airway occlusion pressure (P0.1) is a useful predictor for successful weaning during discontinuation of assisted ventilation (AV) in patients with chronic obstructive pulmonary disease (COPD). We studied 12 patients with COPD receiving AV with maximal inspiratory pressure (MIP) ⩽ −20 cm H2O and FVC ⩾ 10 ml/kg. The P0.1, Vt, frequency, mean inspiratory flow rate (Vt/Ti), inspiratory time to total breath cycle duration (Ti/Ttot), and arterial blood gases were determined just prior to weaning, within 5 min after discontinuing AV (Time 0), and at 30, 60, 90, 120, 180, and 240 min. Five of the 12 patients failed to wean, defined as requiring AV within 24 h after discontinuing AV. At Time 0, all patients who subsequently failed to wean had a P0.1 of greater than 6 cm H2O, and those who were successfully weaned had a P0.1 of less than 6 cm H2O (p < 0.001), although the arterial blood gas determinations were comparable in both groups. Throughout the study perio...